Performance-based pushover cyclic test for innovative prefabricated hybrid industrialised building system sub-frame

The paper presents a pseudo-dynamic cyclic load test to evaluate the structural performance of innovative prefabricated hybrid Industrialised Building System (IBS) subjected to earthquake-induced ground motions. Two beams, three columns and six wall panels with scale of 1:5 were casted using concret...

Full description

Saved in:
Bibliographic Details
Main Authors: Wong, Jing Ying, Marsono, Abdul Kadir, Md. Tap, Masine, Yip, Chun Chieh
Format: Article
Language:English
Published: Penerbit UTM Press 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/58809/1/AbdulKadir2015_Performance-BasedPushoverCyclic.pdf
http://eprints.utm.my/id/eprint/58809/
http://dx.doi.org/10.11113/jt.v74.3372
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.58809
record_format eprints
spelling my.utm.588092021-12-12T08:06:29Z http://eprints.utm.my/id/eprint/58809/ Performance-based pushover cyclic test for innovative prefabricated hybrid industrialised building system sub-frame Wong, Jing Ying Marsono, Abdul Kadir Md. Tap, Masine Yip, Chun Chieh TA Engineering (General). Civil engineering (General) The paper presents a pseudo-dynamic cyclic load test to evaluate the structural performance of innovative prefabricated hybrid Industrialised Building System (IBS) subjected to earthquake-induced ground motions. Two beams, three columns and six wall panels with scale of 1:5 were casted using concrete grade 30. Steel bars with diameters of 6 mm and 1.5 mm were used as main reinforcement and links, respectively. The frame was set-up and tested in two reversal directions of cyclic lateral loads in the structural laboratory. Eight Linear Variable Displacement Transducers (LVDTs) and seven strain gauges were instrumented in the model to record deflections and strains. This experiment was conducted in displacement-controlled mode. Four cycles of loads were applied corresponding to the initial targeted lateral displacement to obtain hysteresis curve. The structural performance was assessed using structural seismic demand parameters such as story displacement, displacement ductility and energy dissipation. Three structural performance levels that were Immediate Occupancy (IO), Life Safety (LS) and Collapse Prevention (CP) were assessed with compliance of FEMA 356. Structural behaviour, localised stressed and failed components were checked and recorded. The experimental results were presented in load-displacement of the system, mapped crack patterns, and development of capacity curve. Damage ranking were proposed based on degree of damage of scaled 1:5 of SMART IBS frame. Penerbit UTM Press 2015 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/58809/1/AbdulKadir2015_Performance-BasedPushoverCyclic.pdf Wong, Jing Ying and Marsono, Abdul Kadir and Md. Tap, Masine and Yip, Chun Chieh (2015) Performance-based pushover cyclic test for innovative prefabricated hybrid industrialised building system sub-frame. Jurnal Teknologi, 74 (1). pp. 91-103. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v74.3372 DOI:10.11113/jt.v74.3372
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Wong, Jing Ying
Marsono, Abdul Kadir
Md. Tap, Masine
Yip, Chun Chieh
Performance-based pushover cyclic test for innovative prefabricated hybrid industrialised building system sub-frame
description The paper presents a pseudo-dynamic cyclic load test to evaluate the structural performance of innovative prefabricated hybrid Industrialised Building System (IBS) subjected to earthquake-induced ground motions. Two beams, three columns and six wall panels with scale of 1:5 were casted using concrete grade 30. Steel bars with diameters of 6 mm and 1.5 mm were used as main reinforcement and links, respectively. The frame was set-up and tested in two reversal directions of cyclic lateral loads in the structural laboratory. Eight Linear Variable Displacement Transducers (LVDTs) and seven strain gauges were instrumented in the model to record deflections and strains. This experiment was conducted in displacement-controlled mode. Four cycles of loads were applied corresponding to the initial targeted lateral displacement to obtain hysteresis curve. The structural performance was assessed using structural seismic demand parameters such as story displacement, displacement ductility and energy dissipation. Three structural performance levels that were Immediate Occupancy (IO), Life Safety (LS) and Collapse Prevention (CP) were assessed with compliance of FEMA 356. Structural behaviour, localised stressed and failed components were checked and recorded. The experimental results were presented in load-displacement of the system, mapped crack patterns, and development of capacity curve. Damage ranking were proposed based on degree of damage of scaled 1:5 of SMART IBS frame.
format Article
author Wong, Jing Ying
Marsono, Abdul Kadir
Md. Tap, Masine
Yip, Chun Chieh
author_facet Wong, Jing Ying
Marsono, Abdul Kadir
Md. Tap, Masine
Yip, Chun Chieh
author_sort Wong, Jing Ying
title Performance-based pushover cyclic test for innovative prefabricated hybrid industrialised building system sub-frame
title_short Performance-based pushover cyclic test for innovative prefabricated hybrid industrialised building system sub-frame
title_full Performance-based pushover cyclic test for innovative prefabricated hybrid industrialised building system sub-frame
title_fullStr Performance-based pushover cyclic test for innovative prefabricated hybrid industrialised building system sub-frame
title_full_unstemmed Performance-based pushover cyclic test for innovative prefabricated hybrid industrialised building system sub-frame
title_sort performance-based pushover cyclic test for innovative prefabricated hybrid industrialised building system sub-frame
publisher Penerbit UTM Press
publishDate 2015
url http://eprints.utm.my/id/eprint/58809/1/AbdulKadir2015_Performance-BasedPushoverCyclic.pdf
http://eprints.utm.my/id/eprint/58809/
http://dx.doi.org/10.11113/jt.v74.3372
_version_ 1720436890585268224