Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics
A sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of darunavir, ritonavir and tenofovir in human plasma. Sample preparation involved a simple liquid-liquid extraction using 200 μL of human plasma extracted w...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Published: |
Wiley-VCH Verlag
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/58279/ https://doi.org/10.1002/jssc.201500250 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.58279 |
---|---|
record_format |
eprints |
spelling |
my.utm.582792022-01-26T02:31:03Z http://eprints.utm.my/id/eprint/58279/ Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics Reddy, A. V. B. Jaafar, Jafariah Aris, A. B. Majid, Z. A. Umar, K. Talib, J. Madhavi, G. Q Science (General) A sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of darunavir, ritonavir and tenofovir in human plasma. Sample preparation involved a simple liquid-liquid extraction using 200 μL of human plasma extracted with methyl tert-butyl ether for three analytes and internal standard. The separation was accomplished on an Acquity UPLC BEH C18 (50 mm x 2.1 mm, 1.7 μm) analytical column using gradient elution of acetonitrile/methanol (80:20, v/v) and 5.0 mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4 mL/min. The linearity of the method ranged between 20.0 and 12 000 ng/mL for darunavir, 2.0 and 2280 ng/mL for ritonavir, and 14.0 and 1600 ng/mL for tenofovir using 200 μL of plasma. The method was completely validated for its selectivity, sensitivity, linearity, precision and accuracy, recovery, matrix effect, stability, and dilution integrity. The extraction recoveries were consistent and ranged between 79.91 and 90.04% for all three analytes and internal standard. The method exhibited good intra-day and inter-day precision between 1.78 and 6.27%. Finally the method was successfully applied for human pharmacokinetic study in eight healthy male volunteers after the oral administration of 600 mg darunavir along with 100 mg ritonavir and 100 mg tenofovir as boosters. Wiley-VCH Verlag 2015 Article PeerReviewed Reddy, A. V. B. and Jaafar, Jafariah and Aris, A. B. and Majid, Z. A. and Umar, K. and Talib, J. and Madhavi, G. (2015) Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics. Journal Of Separation Science, 38 (15). pp. 2580-2587. ISSN 1615-9306 https://doi.org/10.1002/jssc.201500250 DOI: 10.1002/jssc.201500250 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
Q Science (General) |
spellingShingle |
Q Science (General) Reddy, A. V. B. Jaafar, Jafariah Aris, A. B. Majid, Z. A. Umar, K. Talib, J. Madhavi, G. Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics |
description |
A sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of darunavir, ritonavir and tenofovir in human plasma. Sample preparation involved a simple liquid-liquid extraction using 200 μL of human plasma extracted with methyl tert-butyl ether for three analytes and internal standard. The separation was accomplished on an Acquity UPLC BEH C18 (50 mm x 2.1 mm, 1.7 μm) analytical column using gradient elution of acetonitrile/methanol (80:20, v/v) and 5.0 mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4 mL/min. The linearity of the method ranged between 20.0 and 12 000 ng/mL for darunavir, 2.0 and 2280 ng/mL for ritonavir, and 14.0 and 1600 ng/mL for tenofovir using 200 μL of plasma. The method was completely validated for its selectivity, sensitivity, linearity, precision and accuracy, recovery, matrix effect, stability, and dilution integrity. The extraction recoveries were consistent and ranged between 79.91 and 90.04% for all three analytes and internal standard. The method exhibited good intra-day and inter-day precision between 1.78 and 6.27%. Finally the method was successfully applied for human pharmacokinetic study in eight healthy male volunteers after the oral administration of 600 mg darunavir along with 100 mg ritonavir and 100 mg tenofovir as boosters. |
format |
Article |
author |
Reddy, A. V. B. Jaafar, Jafariah Aris, A. B. Majid, Z. A. Umar, K. Talib, J. Madhavi, G. |
author_facet |
Reddy, A. V. B. Jaafar, Jafariah Aris, A. B. Majid, Z. A. Umar, K. Talib, J. Madhavi, G. |
author_sort |
Reddy, A. V. B. |
title |
Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics |
title_short |
Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics |
title_full |
Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics |
title_fullStr |
Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics |
title_full_unstemmed |
Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics |
title_sort |
development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: application to human pharmacokinetics |
publisher |
Wiley-VCH Verlag |
publishDate |
2015 |
url |
http://eprints.utm.my/id/eprint/58279/ https://doi.org/10.1002/jssc.201500250 |
_version_ |
1724073238173057024 |
score |
13.223943 |