Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot-humid climate of Malaysia

The main objectives of this study were to investigate vernacular passive cooling techniques and their potential application for improving indoor thermal comfort of naturally ventilated, modern brick terraced houses in Malaysia. Field measurement was conducted in two traditional timber Malay houses a...

Full description

Saved in:
Bibliographic Details
Main Authors: Hooi, Doris Chyee Toe, Kubota, Tetsu
Format: Article
Published: Elsevier Ltd 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/58094/
http://dx.doi.org/10.1016/j.solener.2015.01.035
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.58094
record_format eprints
spelling my.utm.580942022-04-07T04:22:08Z http://eprints.utm.my/id/eprint/58094/ Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot-humid climate of Malaysia Hooi, Doris Chyee Toe Kubota, Tetsu HD1394-1394.5 Real estate management The main objectives of this study were to investigate vernacular passive cooling techniques and their potential application for improving indoor thermal comfort of naturally ventilated, modern brick terraced houses in Malaysia. Field measurement was conducted in two traditional timber Malay houses and two traditional masonry Chinese shophouses to examine their indoor thermal environments. The results of the former showed that the indoor air temperatures were higher than the outdoor air temperatures by 1 °C during daytime under open window conditions and 2 °C at night under closed window conditions on average. The emphasis was on reducing the temperature of the outdoor air before entering the lightweight house for bodily cooling by cross ventilation. The outdoor air temperature at the Malay house sites was lower than that of the terraced house site by 1.7 °C on average. The results of the latter revealed that indoor air temperatures in rooms that were adjacent to small internal courtyards were lower than the immediate outdoors by about 5 °C on average at the peak period. At night, the indoor air temperatures maintained values that were similar to the outdoors. The small courtyards were effective to cool the high thermal mass structures through nocturnal ventilative and radiative cooling. When assessed using an adaptive thermal comfort equation for hot–humid climates, the periods of indoor operative temperatures exceeding the 80% comfortable upper limit in the Malay houses, Chinese shophouses, daytime ventilated and night ventilated terraced houses were 47%, 7–8%, 91% and 42%, respectively, on fair weather days. Potential passive cooling techniques for the existing terraced houses including night ventilation, roof or ceiling insulation, window and wall shading, small courtyard concept, and microclimate modification and/or urban heat island mitigation were discussed. Elsevier Ltd 2015 Article PeerReviewed Hooi, Doris Chyee Toe and Kubota, Tetsu (2015) Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot-humid climate of Malaysia. Solar Energy, 114 . pp. 229-258. ISSN 0038-092X http://dx.doi.org/10.1016/j.solener.2015.01.035
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic HD1394-1394.5 Real estate management
spellingShingle HD1394-1394.5 Real estate management
Hooi, Doris Chyee Toe
Kubota, Tetsu
Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot-humid climate of Malaysia
description The main objectives of this study were to investigate vernacular passive cooling techniques and their potential application for improving indoor thermal comfort of naturally ventilated, modern brick terraced houses in Malaysia. Field measurement was conducted in two traditional timber Malay houses and two traditional masonry Chinese shophouses to examine their indoor thermal environments. The results of the former showed that the indoor air temperatures were higher than the outdoor air temperatures by 1 °C during daytime under open window conditions and 2 °C at night under closed window conditions on average. The emphasis was on reducing the temperature of the outdoor air before entering the lightweight house for bodily cooling by cross ventilation. The outdoor air temperature at the Malay house sites was lower than that of the terraced house site by 1.7 °C on average. The results of the latter revealed that indoor air temperatures in rooms that were adjacent to small internal courtyards were lower than the immediate outdoors by about 5 °C on average at the peak period. At night, the indoor air temperatures maintained values that were similar to the outdoors. The small courtyards were effective to cool the high thermal mass structures through nocturnal ventilative and radiative cooling. When assessed using an adaptive thermal comfort equation for hot–humid climates, the periods of indoor operative temperatures exceeding the 80% comfortable upper limit in the Malay houses, Chinese shophouses, daytime ventilated and night ventilated terraced houses were 47%, 7–8%, 91% and 42%, respectively, on fair weather days. Potential passive cooling techniques for the existing terraced houses including night ventilation, roof or ceiling insulation, window and wall shading, small courtyard concept, and microclimate modification and/or urban heat island mitigation were discussed.
format Article
author Hooi, Doris Chyee Toe
Kubota, Tetsu
author_facet Hooi, Doris Chyee Toe
Kubota, Tetsu
author_sort Hooi, Doris Chyee Toe
title Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot-humid climate of Malaysia
title_short Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot-humid climate of Malaysia
title_full Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot-humid climate of Malaysia
title_fullStr Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot-humid climate of Malaysia
title_full_unstemmed Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot-humid climate of Malaysia
title_sort comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot-humid climate of malaysia
publisher Elsevier Ltd
publishDate 2015
url http://eprints.utm.my/id/eprint/58094/
http://dx.doi.org/10.1016/j.solener.2015.01.035
_version_ 1729703225377947648
score 13.211869