A study on the early streamer emission (ESE) lightning protection system

Early Streamer Emission (ESE) Lightning Protection (LP) system is a relatively new approach in solving the perennial problem of lightning damage, which has been associated with the use of Franklin Rod (FR). Based on theoretical consideration and some previous work by several researchers, the ESE is...

Full description

Saved in:
Bibliographic Details
Main Author: Ngu, Eng Eng
Format: Thesis
Language:English
Published: 2004
Subjects:
Online Access:http://eprints.utm.my/id/eprint/5774/1/NguEngEngMFKE2004.pdf
http://eprints.utm.my/id/eprint/5774/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:62111
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.5774
record_format eprints
spelling my.utm.57742018-09-19T05:03:14Z http://eprints.utm.my/id/eprint/5774/ A study on the early streamer emission (ESE) lightning protection system Ngu, Eng Eng TK Electrical engineering. Electronics Nuclear engineering Early Streamer Emission (ESE) Lightning Protection (LP) system is a relatively new approach in solving the perennial problem of lightning damage, which has been associated with the use of Franklin Rod (FR). Based on theoretical consideration and some previous work by several researchers, the ESE is believed to be providing more effective protection against lightning than would a FR system. However, the scientific and technical basis to support the belief of this improved system is still not concrete enough and this then inevitably leads to the efficacy of these technologies still remain opened for further study and improvement. The new system is equipped with a special device that is used to extend the effective range of protection over that of the FR. In this work, results have been obtained from the simulated testing carried out in the laboratory and also from field monitoring of real FR and ESE system installed in the university campus. Visits to several sites, which employ these systems, have enabled physical observation of the after effects of lightning be recorded for analyses. The results show that slightly rounded air terminal, which is typical of ESE system offer better interception ability than that of sharp terminals, which is the typical FR design. It is also shown that ionizing the air around the tip of the terminals can enhance its effectiveness. This conclusion is substantiated by field observation obtained from the installed systems where the ESE system has been found to intercept more lightning strikes than that by the FR. 2004-10 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/5774/1/NguEngEngMFKE2004.pdf Ngu, Eng Eng (2004) A study on the early streamer emission (ESE) lightning protection system. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:62111
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Ngu, Eng Eng
A study on the early streamer emission (ESE) lightning protection system
description Early Streamer Emission (ESE) Lightning Protection (LP) system is a relatively new approach in solving the perennial problem of lightning damage, which has been associated with the use of Franklin Rod (FR). Based on theoretical consideration and some previous work by several researchers, the ESE is believed to be providing more effective protection against lightning than would a FR system. However, the scientific and technical basis to support the belief of this improved system is still not concrete enough and this then inevitably leads to the efficacy of these technologies still remain opened for further study and improvement. The new system is equipped with a special device that is used to extend the effective range of protection over that of the FR. In this work, results have been obtained from the simulated testing carried out in the laboratory and also from field monitoring of real FR and ESE system installed in the university campus. Visits to several sites, which employ these systems, have enabled physical observation of the after effects of lightning be recorded for analyses. The results show that slightly rounded air terminal, which is typical of ESE system offer better interception ability than that of sharp terminals, which is the typical FR design. It is also shown that ionizing the air around the tip of the terminals can enhance its effectiveness. This conclusion is substantiated by field observation obtained from the installed systems where the ESE system has been found to intercept more lightning strikes than that by the FR.
format Thesis
author Ngu, Eng Eng
author_facet Ngu, Eng Eng
author_sort Ngu, Eng Eng
title A study on the early streamer emission (ESE) lightning protection system
title_short A study on the early streamer emission (ESE) lightning protection system
title_full A study on the early streamer emission (ESE) lightning protection system
title_fullStr A study on the early streamer emission (ESE) lightning protection system
title_full_unstemmed A study on the early streamer emission (ESE) lightning protection system
title_sort study on the early streamer emission (ese) lightning protection system
publishDate 2004
url http://eprints.utm.my/id/eprint/5774/1/NguEngEngMFKE2004.pdf
http://eprints.utm.my/id/eprint/5774/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:62111
_version_ 1643644398647377920