The effect of liquid suction heat exchanger sub-cooler on performance of a freezer using R404A as working fluid
This study presents the effect of liquid-suction heat exchangers (LSHX) sub-cooler in a freezer. The LSHX sub-cooler is a method to increase the cooling capacity of the evaporator by lowering temperature at the condenser outlet. The decrease in temperature of the condenser outlet will cause a decrea...
Saved in:
Main Authors: | Nuriyadi, Muhammad, Sumeru, Sumeru, Nasution, Henry |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM Press
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/55619/1/HenryNasution2015_TheEffectofLiquidSuctionHeatExchanger.pdf http://eprints.utm.my/id/eprint/55619/ http://dx.doi.org/10.11113/jt.v76.5914 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Energy savings on automotive air conditioner using liquid-suction heat exchanger subcooler
by: Mursanto, Wahyu Budi, et al.
Published: (2014) -
Performance improvement using subcooling on freezer with R22 and R290 as refrigerant for various ambient temperatures
by: Sunardi, Cecep, et al.
Published: (2016) -
Kaji eksperimental retrofit R404A dengan refrigeran ramah lingkungan R290 pada freezer
by: Luga Martin Simbolon, et al.
Published: (2023) -
Evaluation Of Subcooling With Liquid-Suction Heat Exchanger On The Performance Of Air Conditioning System Using R22/R410A/R290/R32 As Refrigerants
by: Sukri, Mohamad Firdaus, et al.
Published: (2019) -
Effect of compressor-discharge-cooler heat-exchanger length using condensate water on the performance of a split-type air conditioner using R32 as working fluid
by: Setyawan, Andriyanto, et al.
Published: (2022)