Strength capacity of bolted shear connectors with cold-formed steel section integrated as composite beam in self-compacting concrete
The use of composite systems comprising of concrete and hot-rolled steel (HRS) sections is well established as observed by extensive rules and requirements for their design as prescribed in current design codes. There is, however, few technical information available about the use of composite system...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM Press
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/55582/1/MustaphaMuhammadLawan2015_StrenghtCapacityofBoltedShearConnectors.pdf http://eprints.utm.my/id/eprint/55582/ http://dx.doi.org/10.11113/jt.v77.6406 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.55582 |
---|---|
record_format |
eprints |
spelling |
my.utm.555822017-11-01T04:17:02Z http://eprints.utm.my/id/eprint/55582/ Strength capacity of bolted shear connectors with cold-formed steel section integrated as composite beam in self-compacting concrete Lawan, Mustapha Muhammad Md. Tahir, Mahmood TA Engineering (General). Civil engineering (General) The use of composite systems comprising of concrete and hot-rolled steel (HRS) sections is well established as observed by extensive rules and requirements for their design as prescribed in current design codes. There is, however, few technical information available about the use of composite systems that incorporates the use of light gauge steel sections, despite the potentials of the system in residential and light industrial constructions. Therefore, this study investigates the strength capacity of bolted shear connectors with cold-formed steel (CFS) section integrated as composite beam in self-compacting concrete. In this paper, four composite beam specimens of dimensions (4500 mm x 1500 mm x 75 mm) with bolted shear connectors of M12 and M14 of grade 8.8 installed on the upper flanges of the coupled back-to-back CFS I-section with longitudinal spacing’s of 250 mm and 300 mm centers and spaced 75 mm laterally were fabricated, cast and tested to failure using four-point bending test. Shear connector size and the longitudinal spacing were the varied parameters, and their influence was investigated on the ultimate load and ultimate moment capacities. The results showed that, the ultimate load and ultimate moment capacities were both influenced remarkably by the studied parameters. However, results of theoretical analysis, revealed good agreement between the experimental and the theoretical results. This shows that, the plastic analysis results for the ultimate moment capacity of the composite beams can be estimated efficiently by using the constitutive laws as prescribed by Eurocodes. Penerbit UTM Press 2015 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/55582/1/MustaphaMuhammadLawan2015_StrenghtCapacityofBoltedShearConnectors.pdf Lawan, Mustapha Muhammad and Md. Tahir, Mahmood (2015) Strength capacity of bolted shear connectors with cold-formed steel section integrated as composite beam in self-compacting concrete. Jurnal Teknologi, 77 (16). pp. 105-112. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v77.6406 DOI:10.11113/jt.v77.6406 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Lawan, Mustapha Muhammad Md. Tahir, Mahmood Strength capacity of bolted shear connectors with cold-formed steel section integrated as composite beam in self-compacting concrete |
description |
The use of composite systems comprising of concrete and hot-rolled steel (HRS) sections is well established as observed by extensive rules and requirements for their design as prescribed in current design codes. There is, however, few technical information available about the use of composite systems that incorporates the use of light gauge steel sections, despite the potentials of the system in residential and light industrial constructions. Therefore, this study investigates the strength capacity of bolted shear connectors with cold-formed steel (CFS) section integrated as composite beam in self-compacting concrete. In this paper, four composite beam specimens of dimensions (4500 mm x 1500 mm x 75 mm) with bolted shear connectors of M12 and M14 of grade 8.8 installed on the upper flanges of the coupled back-to-back CFS I-section with longitudinal spacing’s of 250 mm and 300 mm centers and spaced 75 mm laterally were fabricated, cast and tested to failure using four-point bending test. Shear connector size and the longitudinal spacing were the varied parameters, and their influence was investigated on the ultimate load and ultimate moment capacities. The results showed that, the ultimate load and ultimate moment capacities were both influenced remarkably by the studied parameters. However, results of theoretical analysis, revealed good agreement between the experimental and the theoretical results. This shows that, the plastic analysis results for the ultimate moment capacity of the composite beams can be estimated efficiently by using the constitutive laws as prescribed by Eurocodes. |
format |
Article |
author |
Lawan, Mustapha Muhammad Md. Tahir, Mahmood |
author_facet |
Lawan, Mustapha Muhammad Md. Tahir, Mahmood |
author_sort |
Lawan, Mustapha Muhammad |
title |
Strength capacity of bolted shear connectors with cold-formed steel section integrated as composite beam in self-compacting concrete |
title_short |
Strength capacity of bolted shear connectors with cold-formed steel section integrated as composite beam in self-compacting concrete |
title_full |
Strength capacity of bolted shear connectors with cold-formed steel section integrated as composite beam in self-compacting concrete |
title_fullStr |
Strength capacity of bolted shear connectors with cold-formed steel section integrated as composite beam in self-compacting concrete |
title_full_unstemmed |
Strength capacity of bolted shear connectors with cold-formed steel section integrated as composite beam in self-compacting concrete |
title_sort |
strength capacity of bolted shear connectors with cold-formed steel section integrated as composite beam in self-compacting concrete |
publisher |
Penerbit UTM Press |
publishDate |
2015 |
url |
http://eprints.utm.my/id/eprint/55582/1/MustaphaMuhammadLawan2015_StrenghtCapacityofBoltedShearConnectors.pdf http://eprints.utm.my/id/eprint/55582/ http://dx.doi.org/10.11113/jt.v77.6406 |
_version_ |
1643653840264757248 |
score |
13.211869 |