Investigation of systematic errors for the hybrid and panoramic scanners

The existence of terrestrial laser scanners (TLSs) with capability to provide dense three-dimensional (3D) data in short period of time has made it widely used for the many purposes such as documentation, management and analysis. However, similar to other sensors, data obtained from TLSs also can be...

Full description

Saved in:
Bibliographic Details
Main Authors: Abbas, Mohamed Azwan, Setan, Halim, Majid, Zulkepli, Chong, Albert, Luh, Lau Chong, Idris, Khairulnizam, Mohd. Ariff, Mohd. Farid
Format: Article
Language:English
Published: Penerbit UTM 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/53251/1/HalimSetan2014_Investigationofsystematicerrors.pdf
http://eprints.utm.my/id/eprint/53251/
http://dx.doi.org/10.11113/jt.v71.3827
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.53251
record_format eprints
spelling my.utm.532512018-07-19T07:26:59Z http://eprints.utm.my/id/eprint/53251/ Investigation of systematic errors for the hybrid and panoramic scanners Abbas, Mohamed Azwan Setan, Halim Majid, Zulkepli Chong, Albert Luh, Lau Chong Idris, Khairulnizam Mohd. Ariff, Mohd. Farid HD Industries. Land use. Labor The existence of terrestrial laser scanners (TLSs) with capability to provide dense three-dimensional (3D) data in short period of time has made it widely used for the many purposes such as documentation, management and analysis. However, similar to other sensors, data obtained from TLSs also can be impaired by errors coming from different sources. Then, calibration routine is crucial for the TLSs to ensure the quality of the data. Through self-calibration, this study has performed system calibration for hybrid (Leica ScanStation C10) and panoramic (Faro Photon 120) scanner at the laboratory with dimensions 15.5m x 9m x 3m and more than hundred planar targets that were fairly distributed. Four most significant parameters are derived from well-known error sources of geodetic instruments as constant (a0), collimation axis (b0), trunnion axis (b1) and vertical circle index (c0) errors. Data obtained from seven scan-stations were processed, and statistical analysis (e.g. t-test) has shown significant errors for the calibrated scanners Penerbit UTM 2014 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/53251/1/HalimSetan2014_Investigationofsystematicerrors.pdf Abbas, Mohamed Azwan and Setan, Halim and Majid, Zulkepli and Chong, Albert and Luh, Lau Chong and Idris, Khairulnizam and Mohd. Ariff, Mohd. Farid (2014) Investigation of systematic errors for the hybrid and panoramic scanners. Jurnal Teknologi, 71 (4). pp. 65-70. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v71.3827
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic HD Industries. Land use. Labor
spellingShingle HD Industries. Land use. Labor
Abbas, Mohamed Azwan
Setan, Halim
Majid, Zulkepli
Chong, Albert
Luh, Lau Chong
Idris, Khairulnizam
Mohd. Ariff, Mohd. Farid
Investigation of systematic errors for the hybrid and panoramic scanners
description The existence of terrestrial laser scanners (TLSs) with capability to provide dense three-dimensional (3D) data in short period of time has made it widely used for the many purposes such as documentation, management and analysis. However, similar to other sensors, data obtained from TLSs also can be impaired by errors coming from different sources. Then, calibration routine is crucial for the TLSs to ensure the quality of the data. Through self-calibration, this study has performed system calibration for hybrid (Leica ScanStation C10) and panoramic (Faro Photon 120) scanner at the laboratory with dimensions 15.5m x 9m x 3m and more than hundred planar targets that were fairly distributed. Four most significant parameters are derived from well-known error sources of geodetic instruments as constant (a0), collimation axis (b0), trunnion axis (b1) and vertical circle index (c0) errors. Data obtained from seven scan-stations were processed, and statistical analysis (e.g. t-test) has shown significant errors for the calibrated scanners
format Article
author Abbas, Mohamed Azwan
Setan, Halim
Majid, Zulkepli
Chong, Albert
Luh, Lau Chong
Idris, Khairulnizam
Mohd. Ariff, Mohd. Farid
author_facet Abbas, Mohamed Azwan
Setan, Halim
Majid, Zulkepli
Chong, Albert
Luh, Lau Chong
Idris, Khairulnizam
Mohd. Ariff, Mohd. Farid
author_sort Abbas, Mohamed Azwan
title Investigation of systematic errors for the hybrid and panoramic scanners
title_short Investigation of systematic errors for the hybrid and panoramic scanners
title_full Investigation of systematic errors for the hybrid and panoramic scanners
title_fullStr Investigation of systematic errors for the hybrid and panoramic scanners
title_full_unstemmed Investigation of systematic errors for the hybrid and panoramic scanners
title_sort investigation of systematic errors for the hybrid and panoramic scanners
publisher Penerbit UTM
publishDate 2014
url http://eprints.utm.my/id/eprint/53251/1/HalimSetan2014_Investigationofsystematicerrors.pdf
http://eprints.utm.my/id/eprint/53251/
http://dx.doi.org/10.11113/jt.v71.3827
_version_ 1643653312440958976
score 13.211869