Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection

Most connections that fasten beams to columns are deformable and exhibit a non-linear behaviour between conditions fully fixed and perfectly pinned. Connection flexibility affects both force distribution and deformation in beams and columns of the frame and must be accounted for in a structural anal...

Full description

Saved in:
Bibliographic Details
Main Author: Ahmad, Che Husni
Format: Thesis
Language:English
Published: 2005
Subjects:
Online Access:http://eprints.utm.my/id/eprint/5293/1/CheHusniAhmadMFKA2005.pdf
http://eprints.utm.my/id/eprint/5293/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.5293
record_format eprints
spelling my.utm.52932018-02-28T08:21:03Z http://eprints.utm.my/id/eprint/5293/ Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection Ahmad, Che Husni TA Engineering (General). Civil engineering (General) Most connections that fasten beams to columns are deformable and exhibit a non-linear behaviour between conditions fully fixed and perfectly pinned. Connection flexibility affects both force distribution and deformation in beams and columns of the frame and must be accounted for in a structural analysis. This problem can be solved by conducting a non-linear analysis, which addresses both the geometric non-linearity and connection flexibility. The linear elastic analysis assumes that the deformations are relatively small and the equilibrium equations can be formulated with respect to initial geometry. To see the differences between the above approaches on moment capacity of the connection, a model of A Symmetric Flush End Plate Bolted Beam-to-Column connection model has been analysed using both approaches above. This model will be made similar to the model that had an experimental data for verification. From non-linear computer analysis the moment capacity model is found to be 7.8 kNm compared to experimental data, 8.8 kNm. The moment capacity resulted from linear analysis is found to be 19.5 kNm which is 2.5 time the non-linear analysis result or 2.216 above the experimental data. The results of this study shows an agreement with previous researchers that the connection behaves in between pinne d and fully rigid and possess some rotational stiffness. 2005-11 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/5293/1/CheHusniAhmadMFKA2005.pdf Ahmad, Che Husni (2005) Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Ahmad, Che Husni
Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
description Most connections that fasten beams to columns are deformable and exhibit a non-linear behaviour between conditions fully fixed and perfectly pinned. Connection flexibility affects both force distribution and deformation in beams and columns of the frame and must be accounted for in a structural analysis. This problem can be solved by conducting a non-linear analysis, which addresses both the geometric non-linearity and connection flexibility. The linear elastic analysis assumes that the deformations are relatively small and the equilibrium equations can be formulated with respect to initial geometry. To see the differences between the above approaches on moment capacity of the connection, a model of A Symmetric Flush End Plate Bolted Beam-to-Column connection model has been analysed using both approaches above. This model will be made similar to the model that had an experimental data for verification. From non-linear computer analysis the moment capacity model is found to be 7.8 kNm compared to experimental data, 8.8 kNm. The moment capacity resulted from linear analysis is found to be 19.5 kNm which is 2.5 time the non-linear analysis result or 2.216 above the experimental data. The results of this study shows an agreement with previous researchers that the connection behaves in between pinne d and fully rigid and possess some rotational stiffness.
format Thesis
author Ahmad, Che Husni
author_facet Ahmad, Che Husni
author_sort Ahmad, Che Husni
title Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
title_short Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
title_full Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
title_fullStr Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
title_full_unstemmed Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
title_sort non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
publishDate 2005
url http://eprints.utm.my/id/eprint/5293/1/CheHusniAhmadMFKA2005.pdf
http://eprints.utm.my/id/eprint/5293/
_version_ 1643644283659485184
score 13.250246