Effect of liquid inhibitor De-dio™ on dioxin-furan emission from medical waste incineration plant

The aim of the study was to investigate the effects of liquid inhibitor (known as De-dio™) on the emission of dioxin-furan from medical waste incineration plants. Various concentrations of De-dio™ solutions were tested on the medical waste incinerator combustion chamber with an injection flow rate o...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd. Yusof, Mohd. Rashid, Rashid, Mariyah, Mat, Ramli, Kusnin, Noorhafizah
Format: Article
Language:English
Published: Penerbit UTM 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/52518/1/Mohd.RashidMohd.2014_Effectofliquidinhibitor.pdf
http://eprints.utm.my/id/eprint/52518/
http://dx.doi.org/10.11113/jt.v69.2223
Tags: Add Tag
No Tags, Be the first to tag this record!