High temperature creep behavior of austenitic fe-ni-cr alloy

reep damage investigation was carried out in Fe-Ni-Cr alloy at 800°C, 900°C, and 983°C using rectangular section form of specimen. In all the tests conducted on this material, some creep curves showed primary stage, secondary stage and tertiary stage. The creep fracture shows ductile transgranular f...

全面介紹

Saved in:
書目詳細資料
Main Authors: Hamzah, Esah, Mudang, Maureen, Ang, Khwang Jenq, Khattak, Muhammad Adil
格式: Conference or Workshop Item
出版: 2013
主題:
在線閱讀:http://eprints.utm.my/id/eprint/51099/
https://www.scientific.net/AMR.686.170
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
實物特徵
總結:reep damage investigation was carried out in Fe-Ni-Cr alloy at 800°C, 900°C, and 983°C using rectangular section form of specimen. In all the tests conducted on this material, some creep curves showed primary stage, secondary stage and tertiary stage. The creep fracture shows ductile transgranular fracture where separation occurred at the dendrites carbide interface suggesting that the detrimental effect of creep was compounded by precipitation of carbides at matrix. The presence of cavities may be due to the difference in thermal expansion characteristics of the austenite and carbide during high temperature test. Coarsening of carbides lead to cavities formation within the dendrite and carbide interface and form cavities linkage due to formation of crack and finally cause creep fracture. Increase in creep temperature it will lead to increase in creep rate. The fracture modes of creep samples were investigated to predict the failure mode.