Compton scattering of 662 kev gamma rays by aluminium and copper materials using NAI(TI) detector

A rotating NaI(TI) scintillator detector and a collimated Cs 137 source producing gamma rays with an energy of 662 keV scattered incoherently by aluminum (Al) and copper (Cu) scatterers through the angles from 0 to 120° are used to study Compton scattering. The Compton scattering effect is investiga...

Full description

Saved in:
Bibliographic Details
Main Authors: Hossein, Imam, Azmi, N. A., Saeed, Mohammad Alam, Hoque, Mohammed Ehsan, Viswanathan, K. K., Abdullah, Hewa Y.
Format: Article
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/46718/
http://dx.doi.org/10.5897/IJPS11.1031
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.46718
record_format eprints
spelling my.utm.467182017-09-30T00:33:27Z http://eprints.utm.my/id/eprint/46718/ Compton scattering of 662 kev gamma rays by aluminium and copper materials using NAI(TI) detector Hossein, Imam Azmi, N. A. Saeed, Mohammad Alam Hoque, Mohammed Ehsan Viswanathan, K. K. Abdullah, Hewa Y. Q Science A rotating NaI(TI) scintillator detector and a collimated Cs 137 source producing gamma rays with an energy of 662 keV scattered incoherently by aluminum (Al) and copper (Cu) scatterers through the angles from 0 to 120° are used to study Compton scattering. The Compton scattering effect is investigated and found that the energy of scattered gamma ray decreases as the scattering angles increases. The differential scattering cross-section as a function of scattering angles is also measured. The experimental results of differential scattering cross-sections for Al and Cu scatterers were compared as a function of scattering angle and found to coincide at the higher angle region, although scattering cross-section for Cu are larger than Al scatterer at the lower angles region. 2012 Article PeerReviewed Hossein, Imam and Azmi, N. A. and Saeed, Mohammad Alam and Hoque, Mohammed Ehsan and Viswanathan, K. K. and Abdullah, Hewa Y. (2012) Compton scattering of 662 kev gamma rays by aluminium and copper materials using NAI(TI) detector. International Journal of the Physical Sciences, 7 (4). pp. 544-549. ISSN 1992-1950 http://dx.doi.org/10.5897/IJPS11.1031 10.5897/IJPS11.1031
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic Q Science
spellingShingle Q Science
Hossein, Imam
Azmi, N. A.
Saeed, Mohammad Alam
Hoque, Mohammed Ehsan
Viswanathan, K. K.
Abdullah, Hewa Y.
Compton scattering of 662 kev gamma rays by aluminium and copper materials using NAI(TI) detector
description A rotating NaI(TI) scintillator detector and a collimated Cs 137 source producing gamma rays with an energy of 662 keV scattered incoherently by aluminum (Al) and copper (Cu) scatterers through the angles from 0 to 120° are used to study Compton scattering. The Compton scattering effect is investigated and found that the energy of scattered gamma ray decreases as the scattering angles increases. The differential scattering cross-section as a function of scattering angles is also measured. The experimental results of differential scattering cross-sections for Al and Cu scatterers were compared as a function of scattering angle and found to coincide at the higher angle region, although scattering cross-section for Cu are larger than Al scatterer at the lower angles region.
format Article
author Hossein, Imam
Azmi, N. A.
Saeed, Mohammad Alam
Hoque, Mohammed Ehsan
Viswanathan, K. K.
Abdullah, Hewa Y.
author_facet Hossein, Imam
Azmi, N. A.
Saeed, Mohammad Alam
Hoque, Mohammed Ehsan
Viswanathan, K. K.
Abdullah, Hewa Y.
author_sort Hossein, Imam
title Compton scattering of 662 kev gamma rays by aluminium and copper materials using NAI(TI) detector
title_short Compton scattering of 662 kev gamma rays by aluminium and copper materials using NAI(TI) detector
title_full Compton scattering of 662 kev gamma rays by aluminium and copper materials using NAI(TI) detector
title_fullStr Compton scattering of 662 kev gamma rays by aluminium and copper materials using NAI(TI) detector
title_full_unstemmed Compton scattering of 662 kev gamma rays by aluminium and copper materials using NAI(TI) detector
title_sort compton scattering of 662 kev gamma rays by aluminium and copper materials using nai(ti) detector
publishDate 2012
url http://eprints.utm.my/id/eprint/46718/
http://dx.doi.org/10.5897/IJPS11.1031
_version_ 1643652119507501056
score 13.211869