Effect of magnetic fields on heavy metal and nutrient removal in leachate

The capabilities of leachate treatment to achieve the allowable limit standards are well known to be universal problem. All kinds of technology treatment methods are used but still difficult to reach the minimum standard requirements. Magnetic technology is a physical treatment technique, which is c...

全面介紹

Saved in:
書目詳細資料
主要作者: Wan Mansor, Wan Salida
格式: Thesis
語言:English
出版: 2006
主題:
在線閱讀:http://eprints.utm.my/id/eprint/3894/1/WanSalidaWanMansorMFKA2006.pdf
http://eprints.utm.my/id/eprint/3894/
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my.utm.3894
record_format eprints
spelling my.utm.38942018-01-11T04:39:15Z http://eprints.utm.my/id/eprint/3894/ Effect of magnetic fields on heavy metal and nutrient removal in leachate Wan Mansor, Wan Salida TA Engineering (General). Civil engineering (General) The capabilities of leachate treatment to achieve the allowable limit standards are well known to be universal problem. All kinds of technology treatment methods are used but still difficult to reach the minimum standard requirements. Magnetic technology is a physical treatment technique, which is commonly used in water processing industry. This situation attracts treatment to use the magnetic technology to further increase the leachate treatment capabilities. This study is mainly focused on the capability of the technology to increase the removal of heavy metals and nutrient. The settling of the treated leachate test, which was done, applied to the behavior of the first kinetic model and the settling time, found out to be most suitable after 60 minutes. The results of the test conclude that the capability of heavy metals and nutrient removal can be further increased using the flowing method with magnetic fields; and with different flow rate and circulation time. The study reveals that lower flow rate and higher circulation time will enhance the removal in leachate. Experimental design with a magnetic strength of 0.55 Tesla, a flow rate of 1 mL/s and circulation time at 7 hour shows that the concentrations of Cr, Fe, Mn and PO4 -3 were decreased. The percentage of Cr removal is 92.8 compared to 87.8 without magnet, so as Fe is 72.9 compared to 70.6, Mn is 50.6 compared to 45.5and PO4 -3 is 33.2 compared to 19.6. This study concluded that magnetic technology has the potential to be used to further increase the efficiency of leachate treatment by increasing the removal of heavy metals and nutrient. 2006-05 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/3894/1/WanSalidaWanMansorMFKA2006.pdf Wan Mansor, Wan Salida (2006) Effect of magnetic fields on heavy metal and nutrient removal in leachate. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Wan Mansor, Wan Salida
Effect of magnetic fields on heavy metal and nutrient removal in leachate
description The capabilities of leachate treatment to achieve the allowable limit standards are well known to be universal problem. All kinds of technology treatment methods are used but still difficult to reach the minimum standard requirements. Magnetic technology is a physical treatment technique, which is commonly used in water processing industry. This situation attracts treatment to use the magnetic technology to further increase the leachate treatment capabilities. This study is mainly focused on the capability of the technology to increase the removal of heavy metals and nutrient. The settling of the treated leachate test, which was done, applied to the behavior of the first kinetic model and the settling time, found out to be most suitable after 60 minutes. The results of the test conclude that the capability of heavy metals and nutrient removal can be further increased using the flowing method with magnetic fields; and with different flow rate and circulation time. The study reveals that lower flow rate and higher circulation time will enhance the removal in leachate. Experimental design with a magnetic strength of 0.55 Tesla, a flow rate of 1 mL/s and circulation time at 7 hour shows that the concentrations of Cr, Fe, Mn and PO4 -3 were decreased. The percentage of Cr removal is 92.8 compared to 87.8 without magnet, so as Fe is 72.9 compared to 70.6, Mn is 50.6 compared to 45.5and PO4 -3 is 33.2 compared to 19.6. This study concluded that magnetic technology has the potential to be used to further increase the efficiency of leachate treatment by increasing the removal of heavy metals and nutrient.
format Thesis
author Wan Mansor, Wan Salida
author_facet Wan Mansor, Wan Salida
author_sort Wan Mansor, Wan Salida
title Effect of magnetic fields on heavy metal and nutrient removal in leachate
title_short Effect of magnetic fields on heavy metal and nutrient removal in leachate
title_full Effect of magnetic fields on heavy metal and nutrient removal in leachate
title_fullStr Effect of magnetic fields on heavy metal and nutrient removal in leachate
title_full_unstemmed Effect of magnetic fields on heavy metal and nutrient removal in leachate
title_sort effect of magnetic fields on heavy metal and nutrient removal in leachate
publishDate 2006
url http://eprints.utm.my/id/eprint/3894/1/WanSalidaWanMansorMFKA2006.pdf
http://eprints.utm.my/id/eprint/3894/
_version_ 1643643915015815168
score 13.251813