Use of instantaneous energy of ABR signals for fast detection of wave V

Brainstem evoked response audiometry is a powerful diagnostic technique in audiology, otology and neurology. ABR(Auditory Brainstem Response) machine has been very useful and popular in past two decades for detection of hearing defects and pathologies in newborns and children. In ABR, wave V is the...

Full description

Saved in:
Bibliographic Details
Main Authors: Arooj, Adeela, Muhamed, Mohd. Rushaidin, Shaikh Salleh, Sheikh Hussain, Omar, Mohd. Hafizi
Format: Article
Published: Scientific Research 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/37794/
http://dx.doi.org/10.4236/jbise.2010.38109
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.37794
record_format eprints
spelling my.utm.377942017-05-24T06:14:31Z http://eprints.utm.my/id/eprint/37794/ Use of instantaneous energy of ABR signals for fast detection of wave V Arooj, Adeela Muhamed, Mohd. Rushaidin Shaikh Salleh, Sheikh Hussain Omar, Mohd. Hafizi TJ Mechanical engineering and machinery Brainstem evoked response audiometry is a powerful diagnostic technique in audiology, otology and neurology. ABR(Auditory Brainstem Response) machine has been very useful and popular in past two decades for detection of hearing defects and pathologies in newborns and children. In ABR, wave V is the most prominent and robust wave that has been used as indicator of hearing loss. However, a fast detection of the wave V is necessary in order to implement newborn hearing screening. Researchers have introduced different kind of signal processing technique in order to achieve this target and one of this is Fast Fourier Transform (FFT) and Wavelet Transform. In this study, the instantaneous energy of ABR signal had been introduced as a marker to identify the ABR waves. Study showed that the instantaneous energy of auditory brainstem response can be used as a marker to identify the ABR waves. This study had proposed a platform for fast hearing screening system. Scientific Research 2010-08 Article PeerReviewed Arooj, Adeela and Muhamed, Mohd. Rushaidin and Shaikh Salleh, Sheikh Hussain and Omar, Mohd. Hafizi (2010) Use of instantaneous energy of ABR signals for fast detection of wave V. Journal Biomedical Science and Engineering, 3 (8). pp. 816-821. ISSN 1937-688X http://dx.doi.org/10.4236/jbise.2010.38109 DOI:10.4236/jbise.2010.38109
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Arooj, Adeela
Muhamed, Mohd. Rushaidin
Shaikh Salleh, Sheikh Hussain
Omar, Mohd. Hafizi
Use of instantaneous energy of ABR signals for fast detection of wave V
description Brainstem evoked response audiometry is a powerful diagnostic technique in audiology, otology and neurology. ABR(Auditory Brainstem Response) machine has been very useful and popular in past two decades for detection of hearing defects and pathologies in newborns and children. In ABR, wave V is the most prominent and robust wave that has been used as indicator of hearing loss. However, a fast detection of the wave V is necessary in order to implement newborn hearing screening. Researchers have introduced different kind of signal processing technique in order to achieve this target and one of this is Fast Fourier Transform (FFT) and Wavelet Transform. In this study, the instantaneous energy of ABR signal had been introduced as a marker to identify the ABR waves. Study showed that the instantaneous energy of auditory brainstem response can be used as a marker to identify the ABR waves. This study had proposed a platform for fast hearing screening system.
format Article
author Arooj, Adeela
Muhamed, Mohd. Rushaidin
Shaikh Salleh, Sheikh Hussain
Omar, Mohd. Hafizi
author_facet Arooj, Adeela
Muhamed, Mohd. Rushaidin
Shaikh Salleh, Sheikh Hussain
Omar, Mohd. Hafizi
author_sort Arooj, Adeela
title Use of instantaneous energy of ABR signals for fast detection of wave V
title_short Use of instantaneous energy of ABR signals for fast detection of wave V
title_full Use of instantaneous energy of ABR signals for fast detection of wave V
title_fullStr Use of instantaneous energy of ABR signals for fast detection of wave V
title_full_unstemmed Use of instantaneous energy of ABR signals for fast detection of wave V
title_sort use of instantaneous energy of abr signals for fast detection of wave v
publisher Scientific Research
publishDate 2010
url http://eprints.utm.my/id/eprint/37794/
http://dx.doi.org/10.4236/jbise.2010.38109
_version_ 1643650160413114368
score 13.211869