The effect of over dosage of concrete retarder daratard 40 in concrete

More than 70 % of insitu concrete is produced now by the ready mixed concrete industry in Malaysia. With the increases in economic growth and demand for highrise buildings as well as infrastructures make the industry to determine its own standards of the production by trial mixed design. The issues...

Full description

Saved in:
Bibliographic Details
Main Author: Govidasamy, Jayakumaran
Format: Thesis
Language:English
Published: 2005
Subjects:
Online Access:http://eprints.utm.my/id/eprint/3701/1/JayakumaranGovindasamyMFKA2005.pdf
http://eprints.utm.my/id/eprint/3701/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.3701
record_format eprints
spelling my.utm.37012018-01-10T03:44:09Z http://eprints.utm.my/id/eprint/3701/ The effect of over dosage of concrete retarder daratard 40 in concrete Govidasamy, Jayakumaran TA Engineering (General). Civil engineering (General) More than 70 % of insitu concrete is produced now by the ready mixed concrete industry in Malaysia. With the increases in economic growth and demand for highrise buildings as well as infrastructures make the industry to determine its own standards of the production by trial mixed design. The issues involves in the properties of fresh concrete during the casting stage. A high degree of workability is planned to speed up the construction. The suitable concrete retarder is being used in the fresh concrete to avoid the formation of cold joint due to time needed to place a large volume of concrete in a continuous operation. The chances to over dosage the concrete with retarder become so great and critical at the construction site. Sometimes it takes 2 to 3 days for the concrete to set and harden. It creates many doubt and disputes to engineers in the industries about the strength and durability of the concrete in long run. The study of behavior of the concrete with different dosage of retarder Daratard 40 has been conducted in the lab test prior to practical concrete practice. The investigation may help the industry to achieve the optimum dosage of concrete retarder without compromising the concrete strength. The relationships between slump test and optimum dosage of the Daratard 40 concrete retarder has been established from the study. Slump test a cheap, suitable and more reliable testing method use to detect the cause of over dosage in fresh concrete consent on consistency before placing and compaction works at the site 2005-11 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/3701/1/JayakumaranGovindasamyMFKA2005.pdf Govidasamy, Jayakumaran (2005) The effect of over dosage of concrete retarder daratard 40 in concrete. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Govidasamy, Jayakumaran
The effect of over dosage of concrete retarder daratard 40 in concrete
description More than 70 % of insitu concrete is produced now by the ready mixed concrete industry in Malaysia. With the increases in economic growth and demand for highrise buildings as well as infrastructures make the industry to determine its own standards of the production by trial mixed design. The issues involves in the properties of fresh concrete during the casting stage. A high degree of workability is planned to speed up the construction. The suitable concrete retarder is being used in the fresh concrete to avoid the formation of cold joint due to time needed to place a large volume of concrete in a continuous operation. The chances to over dosage the concrete with retarder become so great and critical at the construction site. Sometimes it takes 2 to 3 days for the concrete to set and harden. It creates many doubt and disputes to engineers in the industries about the strength and durability of the concrete in long run. The study of behavior of the concrete with different dosage of retarder Daratard 40 has been conducted in the lab test prior to practical concrete practice. The investigation may help the industry to achieve the optimum dosage of concrete retarder without compromising the concrete strength. The relationships between slump test and optimum dosage of the Daratard 40 concrete retarder has been established from the study. Slump test a cheap, suitable and more reliable testing method use to detect the cause of over dosage in fresh concrete consent on consistency before placing and compaction works at the site
format Thesis
author Govidasamy, Jayakumaran
author_facet Govidasamy, Jayakumaran
author_sort Govidasamy, Jayakumaran
title The effect of over dosage of concrete retarder daratard 40 in concrete
title_short The effect of over dosage of concrete retarder daratard 40 in concrete
title_full The effect of over dosage of concrete retarder daratard 40 in concrete
title_fullStr The effect of over dosage of concrete retarder daratard 40 in concrete
title_full_unstemmed The effect of over dosage of concrete retarder daratard 40 in concrete
title_sort effect of over dosage of concrete retarder daratard 40 in concrete
publishDate 2005
url http://eprints.utm.my/id/eprint/3701/1/JayakumaranGovindasamyMFKA2005.pdf
http://eprints.utm.my/id/eprint/3701/
_version_ 1643643871340527616
score 13.211869