Performance of a passive device in improving tremor patients' handwriting capability

This paper provides the investigation of the performance One-Degree-of-Freedom system to be implemented in tremors patient writing device to reduce human hand tremor. The One-Degree-of-Freedom of two springs and a mass is proposed to absorb the hand vibration for patients that suffered tremors disea...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd. Yusop, Mohd. Zamri, Md. Zain, Mohd. Zarhamdy, Hussein, Mohamed, As'arry, A.
Format: Book Section
Published: IEEE 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/35744/
http://dx.doi.org/10.1109/ICoBE.2012.6179046
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.35744
record_format eprints
spelling my.utm.357442017-02-02T05:59:11Z http://eprints.utm.my/id/eprint/35744/ Performance of a passive device in improving tremor patients' handwriting capability Mohd. Yusop, Mohd. Zamri Md. Zain, Mohd. Zarhamdy Hussein, Mohamed As'arry, A. TJ Mechanical engineering and machinery This paper provides the investigation of the performance One-Degree-of-Freedom system to be implemented in tremors patient writing device to reduce human hand tremor. The One-Degree-of-Freedom of two springs and a mass is proposed to absorb the hand vibration for patients that suffered tremors disease while writing. The performance of development device is based on drawing Archimedes spiral that done by a tremor patient. IEEE 2012 Book Section PeerReviewed Mohd. Yusop, Mohd. Zamri and Md. Zain, Mohd. Zarhamdy and Hussein, Mohamed and As'arry, A. (2012) Performance of a passive device in improving tremor patients' handwriting capability. In: 2012 International Conference on Biomedical Engineering, ICoBE 2012. IEEE, New York, USA, pp. 400-403. ISBN 978-145771989-9 http://dx.doi.org/10.1109/ICoBE.2012.6179046 DOI:10.1109/ICoBE.2012.6179046
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Mohd. Yusop, Mohd. Zamri
Md. Zain, Mohd. Zarhamdy
Hussein, Mohamed
As'arry, A.
Performance of a passive device in improving tremor patients' handwriting capability
description This paper provides the investigation of the performance One-Degree-of-Freedom system to be implemented in tremors patient writing device to reduce human hand tremor. The One-Degree-of-Freedom of two springs and a mass is proposed to absorb the hand vibration for patients that suffered tremors disease while writing. The performance of development device is based on drawing Archimedes spiral that done by a tremor patient.
format Book Section
author Mohd. Yusop, Mohd. Zamri
Md. Zain, Mohd. Zarhamdy
Hussein, Mohamed
As'arry, A.
author_facet Mohd. Yusop, Mohd. Zamri
Md. Zain, Mohd. Zarhamdy
Hussein, Mohamed
As'arry, A.
author_sort Mohd. Yusop, Mohd. Zamri
title Performance of a passive device in improving tremor patients' handwriting capability
title_short Performance of a passive device in improving tremor patients' handwriting capability
title_full Performance of a passive device in improving tremor patients' handwriting capability
title_fullStr Performance of a passive device in improving tremor patients' handwriting capability
title_full_unstemmed Performance of a passive device in improving tremor patients' handwriting capability
title_sort performance of a passive device in improving tremor patients' handwriting capability
publisher IEEE
publishDate 2012
url http://eprints.utm.my/id/eprint/35744/
http://dx.doi.org/10.1109/ICoBE.2012.6179046
_version_ 1643649827191390208
score 13.211869