Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo
Ultrasonic Tomography has an important role in industry to produce scanned images for various propose. In this paper, producing the cross sectional images of pipe for detecting percentage of attendance of solid, liquid and gas inside the metal pipe has been investigated. The correct method of mounti...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
2012
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/34164/ http://www.ieee.org/conferences_events/conferences/conferencedetails/index.html?Conf_ID=20268 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.34164 |
---|---|
record_format |
eprints |
spelling |
my.utm.341642017-08-29T02:40:52Z http://eprints.utm.my/id/eprint/34164/ Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo Abbaszadeh, Javad Abdul Rahim, Herlina Abdul Rahim, Ruzairi TK Electrical engineering. Electronics Nuclear engineering Ultrasonic Tomography has an important role in industry to produce scanned images for various propose. In this paper, producing the cross sectional images of pipe for detecting percentage of attendance of solid, liquid and gas inside the metal pipe has been investigated. The correct method of mounting of Ultrasonic sensors and behavior of the ultrasonic wave propagation in different layers has been simulated by the use of finite element software (COMSOL Multiphysics 3.5). To increase in practical nondestructive evaluation and inspection, we should increase our understanding of the basic physics and wave mechanics associated with guided wave inspection. Finding the proper ultrasonic sensor base on its efficiency is the main step of designing an Ultrasonic Tomography system. This is done by estimating the resonance frequency of sensor due to manner of ultrasonic wave propagation in different frequencies shown in simulation results. Optimum frequency of the system is proposed 45 kHz. 2012 Conference or Workshop Item PeerReviewed Abbaszadeh, Javad and Abdul Rahim, Herlina and Abdul Rahim, Ruzairi (2012) Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo. In: 2012 8th IEEE Colloquium on Signal Processing & Its Applications, 23-25 Mar 2012, Melaka, Malaysia. http://www.ieee.org/conferences_events/conferences/conferencedetails/index.html?Conf_ID=20268 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Abbaszadeh, Javad Abdul Rahim, Herlina Abdul Rahim, Ruzairi Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo |
description |
Ultrasonic Tomography has an important role in industry to produce scanned images for various propose. In this paper, producing the cross sectional images of pipe for detecting percentage of attendance of solid, liquid and gas inside the metal pipe has been investigated. The correct method of mounting of Ultrasonic sensors and behavior of the ultrasonic wave propagation in different layers has been simulated by the use of finite element software (COMSOL Multiphysics 3.5). To increase in practical nondestructive evaluation and inspection, we should increase our understanding of the basic physics and wave mechanics associated with guided wave inspection. Finding the proper ultrasonic sensor base on its efficiency is the main step of designing an Ultrasonic Tomography system. This is done by estimating the resonance frequency of sensor due to manner of ultrasonic wave propagation in different frequencies shown in simulation results. Optimum frequency of the system is proposed 45 kHz. |
format |
Conference or Workshop Item |
author |
Abbaszadeh, Javad Abdul Rahim, Herlina Abdul Rahim, Ruzairi |
author_facet |
Abbaszadeh, Javad Abdul Rahim, Herlina Abdul Rahim, Ruzairi |
author_sort |
Abbaszadeh, Javad |
title |
Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo |
title_short |
Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo |
title_full |
Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo |
title_fullStr |
Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo |
title_full_unstemmed |
Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo |
title_sort |
optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo |
publishDate |
2012 |
url |
http://eprints.utm.my/id/eprint/34164/ http://www.ieee.org/conferences_events/conferences/conferencedetails/index.html?Conf_ID=20268 |
_version_ |
1643649527092084736 |
score |
13.211869 |