Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo

Ultrasonic Tomography has an important role in industry to produce scanned images for various propose. In this paper, producing the cross sectional images of pipe for detecting percentage of attendance of solid, liquid and gas inside the metal pipe has been investigated. The correct method of mounti...

Full description

Saved in:
Bibliographic Details
Main Authors: Abbaszadeh, Javad, Abdul Rahim, Herlina, Abdul Rahim, Ruzairi
Format: Conference or Workshop Item
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/34164/
http://www.ieee.org/conferences_events/conferences/conferencedetails/index.html?Conf_ID=20268
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.34164
record_format eprints
spelling my.utm.341642017-08-29T02:40:52Z http://eprints.utm.my/id/eprint/34164/ Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo Abbaszadeh, Javad Abdul Rahim, Herlina Abdul Rahim, Ruzairi TK Electrical engineering. Electronics Nuclear engineering Ultrasonic Tomography has an important role in industry to produce scanned images for various propose. In this paper, producing the cross sectional images of pipe for detecting percentage of attendance of solid, liquid and gas inside the metal pipe has been investigated. The correct method of mounting of Ultrasonic sensors and behavior of the ultrasonic wave propagation in different layers has been simulated by the use of finite element software (COMSOL Multiphysics 3.5). To increase in practical nondestructive evaluation and inspection, we should increase our understanding of the basic physics and wave mechanics associated with guided wave inspection. Finding the proper ultrasonic sensor base on its efficiency is the main step of designing an Ultrasonic Tomography system. This is done by estimating the resonance frequency of sensor due to manner of ultrasonic wave propagation in different frequencies shown in simulation results. Optimum frequency of the system is proposed 45 kHz. 2012 Conference or Workshop Item PeerReviewed Abbaszadeh, Javad and Abdul Rahim, Herlina and Abdul Rahim, Ruzairi (2012) Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo. In: 2012 8th IEEE Colloquium on Signal Processing & Its Applications, 23-25 Mar 2012, Melaka, Malaysia. http://www.ieee.org/conferences_events/conferences/conferencedetails/index.html?Conf_ID=20268
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Abbaszadeh, Javad
Abdul Rahim, Herlina
Abdul Rahim, Ruzairi
Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo
description Ultrasonic Tomography has an important role in industry to produce scanned images for various propose. In this paper, producing the cross sectional images of pipe for detecting percentage of attendance of solid, liquid and gas inside the metal pipe has been investigated. The correct method of mounting of Ultrasonic sensors and behavior of the ultrasonic wave propagation in different layers has been simulated by the use of finite element software (COMSOL Multiphysics 3.5). To increase in practical nondestructive evaluation and inspection, we should increase our understanding of the basic physics and wave mechanics associated with guided wave inspection. Finding the proper ultrasonic sensor base on its efficiency is the main step of designing an Ultrasonic Tomography system. This is done by estimating the resonance frequency of sensor due to manner of ultrasonic wave propagation in different frequencies shown in simulation results. Optimum frequency of the system is proposed 45 kHz.
format Conference or Workshop Item
author Abbaszadeh, Javad
Abdul Rahim, Herlina
Abdul Rahim, Ruzairi
author_facet Abbaszadeh, Javad
Abdul Rahim, Herlina
Abdul Rahim, Ruzairi
author_sort Abbaszadeh, Javad
title Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo
title_short Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo
title_full Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo
title_fullStr Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo
title_full_unstemmed Optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo
title_sort optimizing the frequency of ultrasonic tomography system with a metal pipe conveyo
publishDate 2012
url http://eprints.utm.my/id/eprint/34164/
http://www.ieee.org/conferences_events/conferences/conferencedetails/index.html?Conf_ID=20268
_version_ 1643649527092084736
score 13.211869