Programmable syringe pump

This project paper presents on the Programmable Syringe Pump. Since there are many kind of syringe pump in the market which are used in hospitals and medical labs, most often the flow rate of dispensing is always tends to be in-accurate. Problems like start-up delays, occlusion, piston gaskets gets...

Full description

Saved in:
Bibliographic Details
Main Author: Lal Jethi, Permesh
Format: Thesis
Language:English
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/32458/5/PermeshLalJethiMFKE2012.pdf
http://eprints.utm.my/id/eprint/32458/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.32458
record_format eprints
spelling my.utm.324582017-09-30T07:07:29Z http://eprints.utm.my/id/eprint/32458/ Programmable syringe pump Lal Jethi, Permesh TK Electrical engineering. Electronics Nuclear engineering This project paper presents on the Programmable Syringe Pump. Since there are many kind of syringe pump in the market which are used in hospitals and medical labs, most often the flow rate of dispensing is always tends to be in-accurate. Problems like start-up delays, occlusion, piston gaskets gets stuck has been widely being studied. Researches feel that different type of pump can use only a certain size of syringe to solve the problems. However, in this project, a volume rate syringe pump was designed, instead of flow rate. It is understood that the problems also largely is attribute to the mechanical assembly of the pump, whereby friction and complicated gears has been another root cause aside to syringe size. This project has dealt with a simple designed pump with simple mechanical movement, using a ball screw actuator which overcomes friction problem and a suitable stepper motor. In this project, focused was on a discontinuous pump, where volume is dispensed with respect to time and also position indication in length being measured. The calibration is done using time interval and control is done via a Micro-controller. The experiment was done by defining two kinds of volume rate which is a low volume rate (0.4mL/min) and a high volume rate (1mL/min). Measurements of time reach for every minutes of liquid dispensed and also position reached by the syringe was taken down. The experiment is repeated again this time for a different small size of syringe. It is found that, there was no start up delay occurred for both high and volume rate. Furthermore both time and position accuracy was linear, except that for high volume dispensed the position had a slight deviation. Using a small syringe size proved to be much improvement in a high volume dispensed. 2012-07 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/32458/5/PermeshLalJethiMFKE2012.pdf Lal Jethi, Permesh (2012) Programmable syringe pump. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Lal Jethi, Permesh
Programmable syringe pump
description This project paper presents on the Programmable Syringe Pump. Since there are many kind of syringe pump in the market which are used in hospitals and medical labs, most often the flow rate of dispensing is always tends to be in-accurate. Problems like start-up delays, occlusion, piston gaskets gets stuck has been widely being studied. Researches feel that different type of pump can use only a certain size of syringe to solve the problems. However, in this project, a volume rate syringe pump was designed, instead of flow rate. It is understood that the problems also largely is attribute to the mechanical assembly of the pump, whereby friction and complicated gears has been another root cause aside to syringe size. This project has dealt with a simple designed pump with simple mechanical movement, using a ball screw actuator which overcomes friction problem and a suitable stepper motor. In this project, focused was on a discontinuous pump, where volume is dispensed with respect to time and also position indication in length being measured. The calibration is done using time interval and control is done via a Micro-controller. The experiment was done by defining two kinds of volume rate which is a low volume rate (0.4mL/min) and a high volume rate (1mL/min). Measurements of time reach for every minutes of liquid dispensed and also position reached by the syringe was taken down. The experiment is repeated again this time for a different small size of syringe. It is found that, there was no start up delay occurred for both high and volume rate. Furthermore both time and position accuracy was linear, except that for high volume dispensed the position had a slight deviation. Using a small syringe size proved to be much improvement in a high volume dispensed.
format Thesis
author Lal Jethi, Permesh
author_facet Lal Jethi, Permesh
author_sort Lal Jethi, Permesh
title Programmable syringe pump
title_short Programmable syringe pump
title_full Programmable syringe pump
title_fullStr Programmable syringe pump
title_full_unstemmed Programmable syringe pump
title_sort programmable syringe pump
publishDate 2012
url http://eprints.utm.my/id/eprint/32458/5/PermeshLalJethiMFKE2012.pdf
http://eprints.utm.my/id/eprint/32458/
_version_ 1643649045614297088
score 13.211869