Non-invasive imaging of liquid/gas flow using ultrasonic transmission-mode tomography

This paper details the development of non-invasive ultrasonic tomography for imaging liquid and gas flow. Transmission-mode approach has been used for sensing the liquid/gas two-phase flow, which is a kind of strongly inhomogeneous medium. A 16-pair of ultrasonic sensors have been used. By using low...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Rahim, R., Fazalul Rahiman, M. H., Chan, K. S., Nawawi, S. W.
Format: Article
Published: Elsevier 2007
Subjects:
Online Access:http://eprints.utm.my/id/eprint/17123/
http://dx.doi.org/10.1016/j.sna.2006.07.031
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.17123
record_format eprints
spelling my.utm.171232017-02-08T01:15:43Z http://eprints.utm.my/id/eprint/17123/ Non-invasive imaging of liquid/gas flow using ultrasonic transmission-mode tomography Abdul Rahim, R. Fazalul Rahiman, M. H. Chan, K. S. Nawawi, S. W. TK Electrical engineering. Electronics Nuclear engineering This paper details the development of non-invasive ultrasonic tomography for imaging liquid and gas flow. Transmission-mode approach has been used for sensing the liquid/gas two-phase flow, which is a kind of strongly inhomogeneous medium. A 16-pair of ultrasonic sensors have been used. By using low excitation voltage of 20 V, fan-shape beam ultrasonic transmitters will emit ultrasonic pulses to the receivers. The investigations were based on the transmission and the reception of ultrasonic sensors that were mounted circularly on the surface of experimental vessel. The algorithms used to reconstruct the concentration profile for two-phase flow using fan-shape beam scanning geometry were presented. By using Hybrid-Binary Reconstruction algorithm (HBR), a real-time of ultrasonic transmission-mode tomography had been developed. Experiments showed that the performance is acceptable with the image reconstruction speed of ten frames per second. The results of the experiments and possible future improvements were also discussed. Elsevier 2007-04 Article PeerReviewed Abdul Rahim, R. and Fazalul Rahiman, M. H. and Chan, K. S. and Nawawi, S. W. (2007) Non-invasive imaging of liquid/gas flow using ultrasonic transmission-mode tomography. Sensors and Actuators A-PhysicaL , 135 (2). pp. 337-345. http://dx.doi.org/10.1016/j.sna.2006.07.031 10.1016/j.sna.2006.07.031
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Abdul Rahim, R.
Fazalul Rahiman, M. H.
Chan, K. S.
Nawawi, S. W.
Non-invasive imaging of liquid/gas flow using ultrasonic transmission-mode tomography
description This paper details the development of non-invasive ultrasonic tomography for imaging liquid and gas flow. Transmission-mode approach has been used for sensing the liquid/gas two-phase flow, which is a kind of strongly inhomogeneous medium. A 16-pair of ultrasonic sensors have been used. By using low excitation voltage of 20 V, fan-shape beam ultrasonic transmitters will emit ultrasonic pulses to the receivers. The investigations were based on the transmission and the reception of ultrasonic sensors that were mounted circularly on the surface of experimental vessel. The algorithms used to reconstruct the concentration profile for two-phase flow using fan-shape beam scanning geometry were presented. By using Hybrid-Binary Reconstruction algorithm (HBR), a real-time of ultrasonic transmission-mode tomography had been developed. Experiments showed that the performance is acceptable with the image reconstruction speed of ten frames per second. The results of the experiments and possible future improvements were also discussed.
format Article
author Abdul Rahim, R.
Fazalul Rahiman, M. H.
Chan, K. S.
Nawawi, S. W.
author_facet Abdul Rahim, R.
Fazalul Rahiman, M. H.
Chan, K. S.
Nawawi, S. W.
author_sort Abdul Rahim, R.
title Non-invasive imaging of liquid/gas flow using ultrasonic transmission-mode tomography
title_short Non-invasive imaging of liquid/gas flow using ultrasonic transmission-mode tomography
title_full Non-invasive imaging of liquid/gas flow using ultrasonic transmission-mode tomography
title_fullStr Non-invasive imaging of liquid/gas flow using ultrasonic transmission-mode tomography
title_full_unstemmed Non-invasive imaging of liquid/gas flow using ultrasonic transmission-mode tomography
title_sort non-invasive imaging of liquid/gas flow using ultrasonic transmission-mode tomography
publisher Elsevier
publishDate 2007
url http://eprints.utm.my/id/eprint/17123/
http://dx.doi.org/10.1016/j.sna.2006.07.031
_version_ 1643646732401115136
score 13.211869