Application of FACTS devices for damping out power systems oscillations using model techniques

Variable impedance devices using power electronic technology, such as Static VAR Compensators (SVCs) Thyristor-Controlled Series Capacitors (TCSC) and Unified Power Flow Controller (UPFC) have the potential to increase power control and system damping [1, 2]. The allocation of these devices to g...

Full description

Saved in:
Bibliographic Details
Main Authors: Magaji, Nuraddeen, Mustafa, Mohd. Wazir, Mokhtar, Ahmad Safawi
Format: Book Section
Published: Penerbit UTM 2008
Subjects:
Online Access:http://eprints.utm.my/id/eprint/16814/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.16814
record_format eprints
spelling my.utm.168142017-02-05T04:16:15Z http://eprints.utm.my/id/eprint/16814/ Application of FACTS devices for damping out power systems oscillations using model techniques Magaji, Nuraddeen Mustafa, Mohd. Wazir Mokhtar, Ahmad Safawi TK Electrical engineering. Electronics Nuclear engineering Variable impedance devices using power electronic technology, such as Static VAR Compensators (SVCs) Thyristor-Controlled Series Capacitors (TCSC) and Unified Power Flow Controller (UPFC) have the potential to increase power control and system damping [1, 2]. The allocation of these devices to get the most effective stabilisation of system modes is a complex problem that requires consideration of many factors. Major design considerations include the identification of busbars and branches in which to locate the system controllers and the choice of suitable feedback signals to be used as input to a stabilising control function [3-6]. Several analytical criteria for placement of damping controllers have been proposed in the literature. Specifically, modal analysis techniques based on the calculation of participation factors, transfer function residues and controllability and observability indices have been used to identify optimal locations for SVCs, TCSC, UPFC and power system stabilisers [2, 7-11]. The computation of controllability and observability measures is of particular interest as it provides valuable information about system dynamic characteristics and the ability of system controllers to enhance damping. This work presents an efficient analysis and design method to place variable impedance devices for enhancement of small signal stability in complex power systems. Controllability is first explored to allocate damping controllers in those busbars and system branches in which they are more effective to enhance damping of a given subset of critical oscillation modes. Observability indices are, in turn, taken to assess supplementary signals that are to be used in a given controller and which are required to “show” the oscillation mode. In this approach, the computation of controllability and observability is based on a measure of the distance of a state representation from the nearest uncontrollable system [12, 13]. This method is numerically stable and can be used to assess the numerical rank and other properties of state models. The study of inter-area oscillations and placement of controllers is done using modal analysis of a linearised model of the power system that includes a detailed representation of variable impedance controllers. The devices presently considered in this research include SVC, TCSC and UPFC. A reduced order equivalent of the interconnected New England test system (NETS) and New York power system (NYPS) is used to illustrate the proposed algorithms. Penerbit UTM 2008 Book Section PeerReviewed Magaji, Nuraddeen and Mustafa, Mohd. Wazir and Mokhtar, Ahmad Safawi (2008) Application of FACTS devices for damping out power systems oscillations using model techniques. In: Development Of Power System Dynamic For Damping Oscillation. Penerbit UTM , Johor, p. 125. ISBN 978-983-52-0678-8
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Magaji, Nuraddeen
Mustafa, Mohd. Wazir
Mokhtar, Ahmad Safawi
Application of FACTS devices for damping out power systems oscillations using model techniques
description Variable impedance devices using power electronic technology, such as Static VAR Compensators (SVCs) Thyristor-Controlled Series Capacitors (TCSC) and Unified Power Flow Controller (UPFC) have the potential to increase power control and system damping [1, 2]. The allocation of these devices to get the most effective stabilisation of system modes is a complex problem that requires consideration of many factors. Major design considerations include the identification of busbars and branches in which to locate the system controllers and the choice of suitable feedback signals to be used as input to a stabilising control function [3-6]. Several analytical criteria for placement of damping controllers have been proposed in the literature. Specifically, modal analysis techniques based on the calculation of participation factors, transfer function residues and controllability and observability indices have been used to identify optimal locations for SVCs, TCSC, UPFC and power system stabilisers [2, 7-11]. The computation of controllability and observability measures is of particular interest as it provides valuable information about system dynamic characteristics and the ability of system controllers to enhance damping. This work presents an efficient analysis and design method to place variable impedance devices for enhancement of small signal stability in complex power systems. Controllability is first explored to allocate damping controllers in those busbars and system branches in which they are more effective to enhance damping of a given subset of critical oscillation modes. Observability indices are, in turn, taken to assess supplementary signals that are to be used in a given controller and which are required to “show” the oscillation mode. In this approach, the computation of controllability and observability is based on a measure of the distance of a state representation from the nearest uncontrollable system [12, 13]. This method is numerically stable and can be used to assess the numerical rank and other properties of state models. The study of inter-area oscillations and placement of controllers is done using modal analysis of a linearised model of the power system that includes a detailed representation of variable impedance controllers. The devices presently considered in this research include SVC, TCSC and UPFC. A reduced order equivalent of the interconnected New England test system (NETS) and New York power system (NYPS) is used to illustrate the proposed algorithms.
format Book Section
author Magaji, Nuraddeen
Mustafa, Mohd. Wazir
Mokhtar, Ahmad Safawi
author_facet Magaji, Nuraddeen
Mustafa, Mohd. Wazir
Mokhtar, Ahmad Safawi
author_sort Magaji, Nuraddeen
title Application of FACTS devices for damping out power systems oscillations using model techniques
title_short Application of FACTS devices for damping out power systems oscillations using model techniques
title_full Application of FACTS devices for damping out power systems oscillations using model techniques
title_fullStr Application of FACTS devices for damping out power systems oscillations using model techniques
title_full_unstemmed Application of FACTS devices for damping out power systems oscillations using model techniques
title_sort application of facts devices for damping out power systems oscillations using model techniques
publisher Penerbit UTM
publishDate 2008
url http://eprints.utm.my/id/eprint/16814/
_version_ 1643646669014695936
score 13.211869