An investigation of linearity and sensitivity of Fiber Bragg Grating sensors

In this work, we investigate the linearity and sensitivity of Fiber Bragg Grating (FBG) sensors. A simple experimental setup comprising optical spectrum analyzer, tunable laser source and fiber grating may be utilized to obtain the wavelength shift and strain measurements. The sensing principle is b...

詳細記述

保存先:
書誌詳細
主要な著者: Ahmed Tahir, Bashir, Ali, J., Abdul Rahman, Roshanida, Ahmed, A.
フォーマット: 論文
言語:English
出版事項: National Institute of Research and Development for Optoelectronics 2009
主題:
オンライン・アクセス:http://eprints.utm.my/id/eprint/12986/1/AhmedTahirBashir2009_AninvestigationoflinearityandsensitivityofFiberBraggGratingsensors.pdf
http://eprints.utm.my/id/eprint/12986/
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
id my.utm.12986
record_format eprints
spelling my.utm.129862017-02-12T01:35:24Z http://eprints.utm.my/id/eprint/12986/ An investigation of linearity and sensitivity of Fiber Bragg Grating sensors Ahmed Tahir, Bashir Ali, J. Abdul Rahman, Roshanida Ahmed, A. Q Science (General) In this work, we investigate the linearity and sensitivity of Fiber Bragg Grating (FBG) sensors. A simple experimental setup comprising optical spectrum analyzer, tunable laser source and fiber grating may be utilized to obtain the wavelength shift and strain measurements. The sensing principle is based on tracking of Bragg wavelength shifts due to the change of loading conditions. The experiment was performed on a fiber grating bonded specimen plate made of Zinc. From the experiment, measure the wavelength shift and then axial strain corresponding to the variation of applied load/temperature change. Based on the results, a linear response has been observed between applied strain/temperature and Bragg wavelength shift throughout the measured region. It has also been demonstrated that the fiber Bragg grating system is more sensitive for 10cm sensor. The measured sensitivity of 10cm and 15cm sensor is 0.0011nm/µm and 0.0016nm/µm respectively at the same loading conditions. One can also anticipate 0.014nm grating wavelength expansion as a result of temperature change of 1°C to bare FBG fiber. The experimental results are also showing the capability of the proposed system to perform strain/temperature measurements. National Institute of Research and Development for Optoelectronics 2009-11 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/12986/1/AhmedTahirBashir2009_AninvestigationoflinearityandsensitivityofFiberBraggGratingsensors.pdf Ahmed Tahir, Bashir and Ali, J. and Abdul Rahman, Roshanida and Ahmed, A. (2009) An investigation of linearity and sensitivity of Fiber Bragg Grating sensors. Journal of Optoelectronics and Advanced Materials, 11 (11). pp. 1692-1695. ISSN 1454-4164
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic Q Science (General)
spellingShingle Q Science (General)
Ahmed Tahir, Bashir
Ali, J.
Abdul Rahman, Roshanida
Ahmed, A.
An investigation of linearity and sensitivity of Fiber Bragg Grating sensors
description In this work, we investigate the linearity and sensitivity of Fiber Bragg Grating (FBG) sensors. A simple experimental setup comprising optical spectrum analyzer, tunable laser source and fiber grating may be utilized to obtain the wavelength shift and strain measurements. The sensing principle is based on tracking of Bragg wavelength shifts due to the change of loading conditions. The experiment was performed on a fiber grating bonded specimen plate made of Zinc. From the experiment, measure the wavelength shift and then axial strain corresponding to the variation of applied load/temperature change. Based on the results, a linear response has been observed between applied strain/temperature and Bragg wavelength shift throughout the measured region. It has also been demonstrated that the fiber Bragg grating system is more sensitive for 10cm sensor. The measured sensitivity of 10cm and 15cm sensor is 0.0011nm/µm and 0.0016nm/µm respectively at the same loading conditions. One can also anticipate 0.014nm grating wavelength expansion as a result of temperature change of 1°C to bare FBG fiber. The experimental results are also showing the capability of the proposed system to perform strain/temperature measurements.
format Article
author Ahmed Tahir, Bashir
Ali, J.
Abdul Rahman, Roshanida
Ahmed, A.
author_facet Ahmed Tahir, Bashir
Ali, J.
Abdul Rahman, Roshanida
Ahmed, A.
author_sort Ahmed Tahir, Bashir
title An investigation of linearity and sensitivity of Fiber Bragg Grating sensors
title_short An investigation of linearity and sensitivity of Fiber Bragg Grating sensors
title_full An investigation of linearity and sensitivity of Fiber Bragg Grating sensors
title_fullStr An investigation of linearity and sensitivity of Fiber Bragg Grating sensors
title_full_unstemmed An investigation of linearity and sensitivity of Fiber Bragg Grating sensors
title_sort investigation of linearity and sensitivity of fiber bragg grating sensors
publisher National Institute of Research and Development for Optoelectronics
publishDate 2009
url http://eprints.utm.my/id/eprint/12986/1/AhmedTahirBashir2009_AninvestigationoflinearityandsensitivityofFiberBraggGratingsensors.pdf
http://eprints.utm.my/id/eprint/12986/
_version_ 1643646086392315904
score 13.251813