The impact of fault current limiter in power system performance

Continues growth of electrical energy demand is resulting in a corresponding increase in the short circuit in power system. Several solutions have been implemented, including the use of Fault Current Limiter (FCL), in order to reduce circuit breakers rated capacity and to limit the electromagnetics...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd. Ariff, Mohd. Aifaa
Format: Thesis
Language:English
Published: 2009
Subjects:
Online Access:http://eprints.utm.my/id/eprint/12299/6/MohdAifaaAriffMFKE2009.pdf
http://eprints.utm.my/id/eprint/12299/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.12299
record_format eprints
spelling my.utm.122992017-09-17T07:31:26Z http://eprints.utm.my/id/eprint/12299/ The impact of fault current limiter in power system performance Mohd. Ariff, Mohd. Aifaa TK Electrical engineering. Electronics Nuclear engineering Continues growth of electrical energy demand is resulting in a corresponding increase in the short circuit in power system. Several solutions have been implemented, including the use of Fault Current Limiter (FCL), in order to reduce circuit breakers rated capacity and to limit the electromagnetics stress in associated equipment. This project presents a comprehensive study of the impact of fault current limiter in power system performance. The FCL use for this study is solid-state type because it has advantages in term of flexibility and control over superconducting type. In order to evaluate the impact of fault current limiter in power system performance, simulation model of power system performance with solid-state FCL are used. For simulation model development, MATLAB Simulation Tools: SIMULINK software is used. A distribution system fed from single source is used to assess the impact of FCL to power system performance. The FCL is evaluated in term of its performance in limiting fault current from about 50 kA to a lower value of 1.7 kA. Results show that the solid-state FCL is effective for reducing short circuit currents up to 98% and also can be used to protect busbars from voltage sag when the system is subjected to various types of faults. 2009-11 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/12299/6/MohdAifaaAriffMFKE2009.pdf Mohd. Ariff, Mohd. Aifaa (2009) The impact of fault current limiter in power system performance. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Mohd. Ariff, Mohd. Aifaa
The impact of fault current limiter in power system performance
description Continues growth of electrical energy demand is resulting in a corresponding increase in the short circuit in power system. Several solutions have been implemented, including the use of Fault Current Limiter (FCL), in order to reduce circuit breakers rated capacity and to limit the electromagnetics stress in associated equipment. This project presents a comprehensive study of the impact of fault current limiter in power system performance. The FCL use for this study is solid-state type because it has advantages in term of flexibility and control over superconducting type. In order to evaluate the impact of fault current limiter in power system performance, simulation model of power system performance with solid-state FCL are used. For simulation model development, MATLAB Simulation Tools: SIMULINK software is used. A distribution system fed from single source is used to assess the impact of FCL to power system performance. The FCL is evaluated in term of its performance in limiting fault current from about 50 kA to a lower value of 1.7 kA. Results show that the solid-state FCL is effective for reducing short circuit currents up to 98% and also can be used to protect busbars from voltage sag when the system is subjected to various types of faults.
format Thesis
author Mohd. Ariff, Mohd. Aifaa
author_facet Mohd. Ariff, Mohd. Aifaa
author_sort Mohd. Ariff, Mohd. Aifaa
title The impact of fault current limiter in power system performance
title_short The impact of fault current limiter in power system performance
title_full The impact of fault current limiter in power system performance
title_fullStr The impact of fault current limiter in power system performance
title_full_unstemmed The impact of fault current limiter in power system performance
title_sort impact of fault current limiter in power system performance
publishDate 2009
url http://eprints.utm.my/id/eprint/12299/6/MohdAifaaAriffMFKE2009.pdf
http://eprints.utm.my/id/eprint/12299/
_version_ 1643645916016541696
score 13.211869