Tapered angle microfluidic device for cell separation using hydrodynamic principle

Metastasis is responsible for 90% of all cancer-related fatalities. CTCs are difficult to detect due to their rarity. Currently, the devices that aid in the detection of CTCs have limitations, such as a high price, complex apparatus, or low sample purity. Consequently, the purpose of this research i...

全面介紹

Saved in:
書目詳細資料
Main Authors: Jamrus, Muhammad Asyraf, Ahmad, Mohd. Ridzuan
格式: Conference or Workshop Item
出版: 2024
主題:
在線閱讀:http://eprints.utm.my/109078/
http://dx.doi.org/10.1007/978-981-99-7243-2_2
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my.utm.109078
record_format eprints
spelling my.utm.1090782025-01-28T08:25:08Z http://eprints.utm.my/109078/ Tapered angle microfluidic device for cell separation using hydrodynamic principle Jamrus, Muhammad Asyraf Ahmad, Mohd. Ridzuan TK Electrical engineering. Electronics Nuclear engineering Metastasis is responsible for 90% of all cancer-related fatalities. CTCs are difficult to detect due to their rarity. Currently, the devices that aid in the detection of CTCs have limitations, such as a high price, complex apparatus, or low sample purity. Consequently, the purpose of this research is to construct and enhance a microfluidic device with a tapered angle. This device aims to outperform conventional microfluidic devices in terms of cost, sample purity, and apparatus. Using the finite element simulation software COMSOL Multiphysics, two studies are conducted, the first of which examines the effect of taper angle on particle separation and the second of which examines the effect of flow rate on particle separation. This design enables particle separation based on hydrodynamic theory and the sedimentation process. A mixture of 3 μm and 10 μm polystyrene (PS) microbeads were effectively separated when the taper angle approached 20 degrees, and separation continued until the taper angle reached 89 degrees. Using 12° and 6° taper angles, 3 μm, and 10 μm polystyrene microbeads were not effectively separated using finite element simulation. The proposed product is functionally enticing despite the fact that this design utilizes a passive separation technique. This technology provides uncomplicated, label-free, continuous separation of numerous particles in a self-contained device without the need for cumbersome equipment. Consequently, both point-of-care diagnostic instruments and micro total analytic systems could utilize this device. 2024 Conference or Workshop Item PeerReviewed Jamrus, Muhammad Asyraf and Ahmad, Mohd. Ridzuan (2024) Tapered angle microfluidic device for cell separation using hydrodynamic principle. In: 22nd Asia Simulation Conference, AsiaSim 2023, 25 October 2023 - 26 October 2023, Langkawi, Kedah, Malaysia. http://dx.doi.org/10.1007/978-981-99-7243-2_2
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Jamrus, Muhammad Asyraf
Ahmad, Mohd. Ridzuan
Tapered angle microfluidic device for cell separation using hydrodynamic principle
description Metastasis is responsible for 90% of all cancer-related fatalities. CTCs are difficult to detect due to their rarity. Currently, the devices that aid in the detection of CTCs have limitations, such as a high price, complex apparatus, or low sample purity. Consequently, the purpose of this research is to construct and enhance a microfluidic device with a tapered angle. This device aims to outperform conventional microfluidic devices in terms of cost, sample purity, and apparatus. Using the finite element simulation software COMSOL Multiphysics, two studies are conducted, the first of which examines the effect of taper angle on particle separation and the second of which examines the effect of flow rate on particle separation. This design enables particle separation based on hydrodynamic theory and the sedimentation process. A mixture of 3 μm and 10 μm polystyrene (PS) microbeads were effectively separated when the taper angle approached 20 degrees, and separation continued until the taper angle reached 89 degrees. Using 12° and 6° taper angles, 3 μm, and 10 μm polystyrene microbeads were not effectively separated using finite element simulation. The proposed product is functionally enticing despite the fact that this design utilizes a passive separation technique. This technology provides uncomplicated, label-free, continuous separation of numerous particles in a self-contained device without the need for cumbersome equipment. Consequently, both point-of-care diagnostic instruments and micro total analytic systems could utilize this device.
format Conference or Workshop Item
author Jamrus, Muhammad Asyraf
Ahmad, Mohd. Ridzuan
author_facet Jamrus, Muhammad Asyraf
Ahmad, Mohd. Ridzuan
author_sort Jamrus, Muhammad Asyraf
title Tapered angle microfluidic device for cell separation using hydrodynamic principle
title_short Tapered angle microfluidic device for cell separation using hydrodynamic principle
title_full Tapered angle microfluidic device for cell separation using hydrodynamic principle
title_fullStr Tapered angle microfluidic device for cell separation using hydrodynamic principle
title_full_unstemmed Tapered angle microfluidic device for cell separation using hydrodynamic principle
title_sort tapered angle microfluidic device for cell separation using hydrodynamic principle
publishDate 2024
url http://eprints.utm.my/109078/
http://dx.doi.org/10.1007/978-981-99-7243-2_2
_version_ 1827439211608801280
score 13.251813