3D image reconstruction capability of peripheral on-chip ECT sensor

The miniaturisation of electrical tomography sensors such as EIT has become popular recently and these miniaturised sensors were investigated for 2D and 3D imaging of cells in EIT. Nevertheless, research on miniaturisation of ECT sensor also existed which were based on peripheral electrode sensor wh...

Full description

Saved in:
Bibliographic Details
Main Authors: Gooi, Wen Pin, Leow, Pei Ling, Pusppanathan, Jaysuman, Hor, Xian Feng, Mohammad Din, Shahrulnizahani
Format: Article
Language:English
Published: Penerbit UTM Press 2023
Subjects:
Online Access:http://eprints.utm.my/108572/1/LeowPeiLing2023_3DImageReconstructionCapabilityofPeripheral.pdf
http://eprints.utm.my/108572/
http://dx.doi.org/10.11113/elektrika.v22n2.437
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.108572
record_format eprints
spelling my.utm.1085722024-11-20T07:53:55Z http://eprints.utm.my/108572/ 3D image reconstruction capability of peripheral on-chip ECT sensor Gooi, Wen Pin Leow, Pei Ling Pusppanathan, Jaysuman Hor, Xian Feng Mohammad Din, Shahrulnizahani TK Electrical engineering. Electronics Nuclear engineering The miniaturisation of electrical tomography sensors such as EIT has become popular recently and these miniaturised sensors were investigated for 2D and 3D imaging of cells in EIT. Nevertheless, research on miniaturisation of ECT sensor also existed which were based on peripheral electrode sensor which had electrodes arranged on the surface around the sensing chamber. However, the study on the miniature peripheral ECT sensor was limited to 2D image reconstruction and detection of presents of samples in the sensing chamber only and lacked the works on the 3D imaging capability. Therefore, this article investigates the 3D image reconstruction capability of peripheral on-chip ECT sensor through simulation approach by simulating a cube phantom at several test positions in the sensing chamber. Eventually, the 3D and 2D images were reconstructed and the 3D imaging capability of the sensor was characterised qualitatively based on visual inspection of the reconstructed image. The simulation results revealed that the 3D imaging capability of peripheral on-chip ECT sensor was limited to the region where electrodes were present only. However, the 2D reconstructed image results showed that the sensor was able to locate the positions of test phantom in the sensing chamber accurately. Penerbit UTM Press 2023 Article PeerReviewed application/pdf en http://eprints.utm.my/108572/1/LeowPeiLing2023_3DImageReconstructionCapabilityofPeripheral.pdf Gooi, Wen Pin and Leow, Pei Ling and Pusppanathan, Jaysuman and Hor, Xian Feng and Mohammad Din, Shahrulnizahani (2023) 3D image reconstruction capability of peripheral on-chip ECT sensor. ELEKTRIKA- Journal of Electrical Engineering, 22 (2). pp. 8-13. ISSN 0128-4428 http://dx.doi.org/10.11113/elektrika.v22n2.437 DOI : 10.11113/elektrika.v22n2.437
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Gooi, Wen Pin
Leow, Pei Ling
Pusppanathan, Jaysuman
Hor, Xian Feng
Mohammad Din, Shahrulnizahani
3D image reconstruction capability of peripheral on-chip ECT sensor
description The miniaturisation of electrical tomography sensors such as EIT has become popular recently and these miniaturised sensors were investigated for 2D and 3D imaging of cells in EIT. Nevertheless, research on miniaturisation of ECT sensor also existed which were based on peripheral electrode sensor which had electrodes arranged on the surface around the sensing chamber. However, the study on the miniature peripheral ECT sensor was limited to 2D image reconstruction and detection of presents of samples in the sensing chamber only and lacked the works on the 3D imaging capability. Therefore, this article investigates the 3D image reconstruction capability of peripheral on-chip ECT sensor through simulation approach by simulating a cube phantom at several test positions in the sensing chamber. Eventually, the 3D and 2D images were reconstructed and the 3D imaging capability of the sensor was characterised qualitatively based on visual inspection of the reconstructed image. The simulation results revealed that the 3D imaging capability of peripheral on-chip ECT sensor was limited to the region where electrodes were present only. However, the 2D reconstructed image results showed that the sensor was able to locate the positions of test phantom in the sensing chamber accurately.
format Article
author Gooi, Wen Pin
Leow, Pei Ling
Pusppanathan, Jaysuman
Hor, Xian Feng
Mohammad Din, Shahrulnizahani
author_facet Gooi, Wen Pin
Leow, Pei Ling
Pusppanathan, Jaysuman
Hor, Xian Feng
Mohammad Din, Shahrulnizahani
author_sort Gooi, Wen Pin
title 3D image reconstruction capability of peripheral on-chip ECT sensor
title_short 3D image reconstruction capability of peripheral on-chip ECT sensor
title_full 3D image reconstruction capability of peripheral on-chip ECT sensor
title_fullStr 3D image reconstruction capability of peripheral on-chip ECT sensor
title_full_unstemmed 3D image reconstruction capability of peripheral on-chip ECT sensor
title_sort 3d image reconstruction capability of peripheral on-chip ect sensor
publisher Penerbit UTM Press
publishDate 2023
url http://eprints.utm.my/108572/1/LeowPeiLing2023_3DImageReconstructionCapabilityofPeripheral.pdf
http://eprints.utm.my/108572/
http://dx.doi.org/10.11113/elektrika.v22n2.437
_version_ 1817841618038816768
score 13.244413