3D image reconstruction capability of peripheral on-chip ECT sensor
The miniaturisation of electrical tomography sensors such as EIT has become popular recently and these miniaturised sensors were investigated for 2D and 3D imaging of cells in EIT. Nevertheless, research on miniaturisation of ECT sensor also existed which were based on peripheral electrode sensor wh...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM Press
2023
|
Subjects: | |
Online Access: | http://eprints.utm.my/108572/1/LeowPeiLing2023_3DImageReconstructionCapabilityofPeripheral.pdf http://eprints.utm.my/108572/ http://dx.doi.org/10.11113/elektrika.v22n2.437 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.108572 |
---|---|
record_format |
eprints |
spelling |
my.utm.1085722024-11-20T07:53:55Z http://eprints.utm.my/108572/ 3D image reconstruction capability of peripheral on-chip ECT sensor Gooi, Wen Pin Leow, Pei Ling Pusppanathan, Jaysuman Hor, Xian Feng Mohammad Din, Shahrulnizahani TK Electrical engineering. Electronics Nuclear engineering The miniaturisation of electrical tomography sensors such as EIT has become popular recently and these miniaturised sensors were investigated for 2D and 3D imaging of cells in EIT. Nevertheless, research on miniaturisation of ECT sensor also existed which were based on peripheral electrode sensor which had electrodes arranged on the surface around the sensing chamber. However, the study on the miniature peripheral ECT sensor was limited to 2D image reconstruction and detection of presents of samples in the sensing chamber only and lacked the works on the 3D imaging capability. Therefore, this article investigates the 3D image reconstruction capability of peripheral on-chip ECT sensor through simulation approach by simulating a cube phantom at several test positions in the sensing chamber. Eventually, the 3D and 2D images were reconstructed and the 3D imaging capability of the sensor was characterised qualitatively based on visual inspection of the reconstructed image. The simulation results revealed that the 3D imaging capability of peripheral on-chip ECT sensor was limited to the region where electrodes were present only. However, the 2D reconstructed image results showed that the sensor was able to locate the positions of test phantom in the sensing chamber accurately. Penerbit UTM Press 2023 Article PeerReviewed application/pdf en http://eprints.utm.my/108572/1/LeowPeiLing2023_3DImageReconstructionCapabilityofPeripheral.pdf Gooi, Wen Pin and Leow, Pei Ling and Pusppanathan, Jaysuman and Hor, Xian Feng and Mohammad Din, Shahrulnizahani (2023) 3D image reconstruction capability of peripheral on-chip ECT sensor. ELEKTRIKA- Journal of Electrical Engineering, 22 (2). pp. 8-13. ISSN 0128-4428 http://dx.doi.org/10.11113/elektrika.v22n2.437 DOI : 10.11113/elektrika.v22n2.437 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Gooi, Wen Pin Leow, Pei Ling Pusppanathan, Jaysuman Hor, Xian Feng Mohammad Din, Shahrulnizahani 3D image reconstruction capability of peripheral on-chip ECT sensor |
description |
The miniaturisation of electrical tomography sensors such as EIT has become popular recently and these miniaturised sensors were investigated for 2D and 3D imaging of cells in EIT. Nevertheless, research on miniaturisation of ECT sensor also existed which were based on peripheral electrode sensor which had electrodes arranged on the surface around the sensing chamber. However, the study on the miniature peripheral ECT sensor was limited to 2D image reconstruction and detection of presents of samples in the sensing chamber only and lacked the works on the 3D imaging capability. Therefore, this article investigates the 3D image reconstruction capability of peripheral on-chip ECT sensor through simulation approach by simulating a cube phantom at several test positions in the sensing chamber. Eventually, the 3D and 2D images were reconstructed and the 3D imaging capability of the sensor was characterised qualitatively based on visual inspection of the reconstructed image. The simulation results revealed that the 3D imaging capability of peripheral on-chip ECT sensor was limited to the region where electrodes were present only. However, the 2D reconstructed image results showed that the sensor was able to locate the positions of test phantom in the sensing chamber accurately. |
format |
Article |
author |
Gooi, Wen Pin Leow, Pei Ling Pusppanathan, Jaysuman Hor, Xian Feng Mohammad Din, Shahrulnizahani |
author_facet |
Gooi, Wen Pin Leow, Pei Ling Pusppanathan, Jaysuman Hor, Xian Feng Mohammad Din, Shahrulnizahani |
author_sort |
Gooi, Wen Pin |
title |
3D image reconstruction capability of peripheral on-chip ECT sensor |
title_short |
3D image reconstruction capability of peripheral on-chip ECT sensor |
title_full |
3D image reconstruction capability of peripheral on-chip ECT sensor |
title_fullStr |
3D image reconstruction capability of peripheral on-chip ECT sensor |
title_full_unstemmed |
3D image reconstruction capability of peripheral on-chip ECT sensor |
title_sort |
3d image reconstruction capability of peripheral on-chip ect sensor |
publisher |
Penerbit UTM Press |
publishDate |
2023 |
url |
http://eprints.utm.my/108572/1/LeowPeiLing2023_3DImageReconstructionCapabilityofPeripheral.pdf http://eprints.utm.my/108572/ http://dx.doi.org/10.11113/elektrika.v22n2.437 |
_version_ |
1817841618038816768 |
score |
13.244413 |