Evaluation of microbial contamination for pre- and post-surgical procedures in hospital operating rooms: A systematic onsite sampling

The risk of surgical site infections (SSIs) is highly associated with the level of microbial contamination settled on a patient's wound. Low or zero microbial contamination could reduce the risk of patients contracting SSIs. To date, the state of microbial contamination in an operating room (OR...

Full description

Saved in:
Bibliographic Details
Main Authors: Tan, Huiyi, Lee, Chew Tin, Othman, Mohd. Hafiz Dzarfan, Zubir, Muhammad Afiq, Nyakuma, Bemgba Bevan, Chong, Wen Tong, Fan, Yee Van, Wong, Keng Yinn
Format: Article
Language:English
Published: Italian Association of Chemical Engineering - AIDIC 2023
Subjects:
Online Access:http://eprints.utm.my/105975/1/WongKengYinn2023_EvaluationofMicrobialContaminationforPreandPostSurgical.pdf
http://eprints.utm.my/105975/
http://dx.doi.org/10.3303/CET23106101
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.105975
record_format eprints
spelling my.utm.1059752024-05-26T09:41:11Z http://eprints.utm.my/105975/ Evaluation of microbial contamination for pre- and post-surgical procedures in hospital operating rooms: A systematic onsite sampling Tan, Huiyi Lee, Chew Tin Othman, Mohd. Hafiz Dzarfan Zubir, Muhammad Afiq Nyakuma, Bemgba Bevan Chong, Wen Tong Fan, Yee Van Wong, Keng Yinn TJ Mechanical engineering and machinery The risk of surgical site infections (SSIs) is highly associated with the level of microbial contamination settled on a patient's wound. Low or zero microbial contamination could reduce the risk of patients contracting SSIs. To date, the state of microbial contamination in an operating room (OR) for pre- and post-surgery is rarely examined. This exploration is crucial as a patient undergoing surgery tends to contract the SSI if the microbial contamination is high. This study aims to identify the number of microbes present in the OR for pre- and post-surgical procedures. Microbial sampling was performed on 15 ORs in 6 private hospitals located on the western coast of Peninsular Malaysia. Before the microbial sampling, cleanroom performance testing (CPT) was performed to ensure the compliance of operating parameters with the International Organization for Standardization (ISO) Class 7. The CPT was conducted based on ISO 14644-1, Institute of Environmental Science Recommended Practice (IES-RP-CC006.2), and National Environmental Balancing Bureau (NEBB) Procedural Standards for Certified Testing of Cleanrooms. The CPT procedures involved verifying the cleanroom operating parameters: air change rate, differential room pressure, relative humidity (RH), and air temperature. The CPT shows that the air change rate, differential room pressure, RH, and air temperature fell within the recommended operating conditions, ranging from 28/h - 45/h, 6.8 Pa - 22.3 Pa, 51.8 % – 58.9 %, 18.2 °C – 21.6 °C, respectively. The microbes were measured in two phases: pre- and post-surgical procedures. The present study confirms that the microbial contamination for post-surgical procedures increased significantly compared to pre-surgical procedures. The increase in microbial contamination of pre- and post-surgical procedures ranged from 49 to 81 colony-forming units (CFU). Italian Association of Chemical Engineering - AIDIC 2023 Article PeerReviewed application/pdf en http://eprints.utm.my/105975/1/WongKengYinn2023_EvaluationofMicrobialContaminationforPreandPostSurgical.pdf Tan, Huiyi and Lee, Chew Tin and Othman, Mohd. Hafiz Dzarfan and Zubir, Muhammad Afiq and Nyakuma, Bemgba Bevan and Chong, Wen Tong and Fan, Yee Van and Wong, Keng Yinn (2023) Evaluation of microbial contamination for pre- and post-surgical procedures in hospital operating rooms: A systematic onsite sampling. Chemical Engineering Transactions, 106 (NA). pp. 601-606. ISSN 2283-9216 http://dx.doi.org/10.3303/CET23106101 DOI : 10.3303/CET23106101
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Tan, Huiyi
Lee, Chew Tin
Othman, Mohd. Hafiz Dzarfan
Zubir, Muhammad Afiq
Nyakuma, Bemgba Bevan
Chong, Wen Tong
Fan, Yee Van
Wong, Keng Yinn
Evaluation of microbial contamination for pre- and post-surgical procedures in hospital operating rooms: A systematic onsite sampling
description The risk of surgical site infections (SSIs) is highly associated with the level of microbial contamination settled on a patient's wound. Low or zero microbial contamination could reduce the risk of patients contracting SSIs. To date, the state of microbial contamination in an operating room (OR) for pre- and post-surgery is rarely examined. This exploration is crucial as a patient undergoing surgery tends to contract the SSI if the microbial contamination is high. This study aims to identify the number of microbes present in the OR for pre- and post-surgical procedures. Microbial sampling was performed on 15 ORs in 6 private hospitals located on the western coast of Peninsular Malaysia. Before the microbial sampling, cleanroom performance testing (CPT) was performed to ensure the compliance of operating parameters with the International Organization for Standardization (ISO) Class 7. The CPT was conducted based on ISO 14644-1, Institute of Environmental Science Recommended Practice (IES-RP-CC006.2), and National Environmental Balancing Bureau (NEBB) Procedural Standards for Certified Testing of Cleanrooms. The CPT procedures involved verifying the cleanroom operating parameters: air change rate, differential room pressure, relative humidity (RH), and air temperature. The CPT shows that the air change rate, differential room pressure, RH, and air temperature fell within the recommended operating conditions, ranging from 28/h - 45/h, 6.8 Pa - 22.3 Pa, 51.8 % – 58.9 %, 18.2 °C – 21.6 °C, respectively. The microbes were measured in two phases: pre- and post-surgical procedures. The present study confirms that the microbial contamination for post-surgical procedures increased significantly compared to pre-surgical procedures. The increase in microbial contamination of pre- and post-surgical procedures ranged from 49 to 81 colony-forming units (CFU).
format Article
author Tan, Huiyi
Lee, Chew Tin
Othman, Mohd. Hafiz Dzarfan
Zubir, Muhammad Afiq
Nyakuma, Bemgba Bevan
Chong, Wen Tong
Fan, Yee Van
Wong, Keng Yinn
author_facet Tan, Huiyi
Lee, Chew Tin
Othman, Mohd. Hafiz Dzarfan
Zubir, Muhammad Afiq
Nyakuma, Bemgba Bevan
Chong, Wen Tong
Fan, Yee Van
Wong, Keng Yinn
author_sort Tan, Huiyi
title Evaluation of microbial contamination for pre- and post-surgical procedures in hospital operating rooms: A systematic onsite sampling
title_short Evaluation of microbial contamination for pre- and post-surgical procedures in hospital operating rooms: A systematic onsite sampling
title_full Evaluation of microbial contamination for pre- and post-surgical procedures in hospital operating rooms: A systematic onsite sampling
title_fullStr Evaluation of microbial contamination for pre- and post-surgical procedures in hospital operating rooms: A systematic onsite sampling
title_full_unstemmed Evaluation of microbial contamination for pre- and post-surgical procedures in hospital operating rooms: A systematic onsite sampling
title_sort evaluation of microbial contamination for pre- and post-surgical procedures in hospital operating rooms: a systematic onsite sampling
publisher Italian Association of Chemical Engineering - AIDIC
publishDate 2023
url http://eprints.utm.my/105975/1/WongKengYinn2023_EvaluationofMicrobialContaminationforPreandPostSurgical.pdf
http://eprints.utm.my/105975/
http://dx.doi.org/10.3303/CET23106101
_version_ 1800714785056096256
score 13.211869