Use of tourmaline-based healthcare products and associated radiation risks

Investigation is made of 23 commercially available tourmaline-based healthcare products containing naturally occurring radioactive material (the products including hot spa stones, face masks, waist supporter slimming belts, arm relief belts, socks, insoles, soaps, and combs) with negative ion health...

Full description

Saved in:
Bibliographic Details
Main Authors: Hassan, Halmat Jalal, Hashim, Suhairul, Abu Hanifah, N. Z. H., Mohd. Sanusi, Mohammad Syazwan, Fahmi, M. R., Mohd. Tahar, Rozman, Bradley, David A.
Format: Article
Published: Elsevier Ltd 2022
Subjects:
Online Access:http://eprints.utm.my/103905/
http://dx.doi.org/10.1016/j.radphyschem.2022.110276
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.103905
record_format eprints
spelling my.utm.1039052023-12-06T04:36:13Z http://eprints.utm.my/103905/ Use of tourmaline-based healthcare products and associated radiation risks Hassan, Halmat Jalal Hashim, Suhairul Abu Hanifah, N. Z. H. Mohd. Sanusi, Mohammad Syazwan Fahmi, M. R. Mohd. Tahar, Rozman Bradley, David A. QC Physics Investigation is made of 23 commercially available tourmaline-based healthcare products containing naturally occurring radioactive material (the products including hot spa stones, face masks, waist supporter slimming belts, arm relief belts, socks, insoles, soaps, and combs) with negative ion health benefits claimed by the purveyors. Assessment is made of the radiological risk posed by the use of such products, external exposure dose being the particular focus. Gamma spectroscopy analysis and Geant4 Monte Carlo (GMC) simulations are used. Organ doses are obtained using male and female human phantoms, dose conversion factors (DCFs) being included. For 238U and 232tTh the tourmaline sock, code T20 was found to contain the greatest activity, at 2.4 ± 0.2 and 28.0 ± 1.3 Bq g ̶ 1 respectively; least was for the magnetic therapy face mask, code T02, at respective values 0.04 ± 0.01 and 0.1 ± 0.01 Bq g ̶ 1. Across all of the tourmaline products, the 4 K range was 0.16 ± 0.01–16.4 ± 1.1 Bq g ̶ 1. In terms of elemental concentration, sample T20 offered the greatest concentration, with mean percentages of 0.022 ± 0.001 and 0.78 ± 0.10, for Th and U, respectively. With the assumption of exposure for a period of 8 h per day, wearing the tourmaline sock product T20 would give rise to an annual effective dose of 0.64 mSv, less than the public annual dose limit of 1 mSv. Noting that the samples may give rise to greater doses, national screening programmes for activity are suggested in seeking to mitigate unnecessary radiation exposure. Elsevier Ltd 2022-11 Article PeerReviewed Hassan, Halmat Jalal and Hashim, Suhairul and Abu Hanifah, N. Z. H. and Mohd. Sanusi, Mohammad Syazwan and Fahmi, M. R. and Mohd. Tahar, Rozman and Bradley, David A. (2022) Use of tourmaline-based healthcare products and associated radiation risks. Radiation Physics and Chemistry, 200 (NA). pp. 1-8. ISSN 0969-806X http://dx.doi.org/10.1016/j.radphyschem.2022.110276 DOI:10.1016/j.radphyschem.2022.110276
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QC Physics
spellingShingle QC Physics
Hassan, Halmat Jalal
Hashim, Suhairul
Abu Hanifah, N. Z. H.
Mohd. Sanusi, Mohammad Syazwan
Fahmi, M. R.
Mohd. Tahar, Rozman
Bradley, David A.
Use of tourmaline-based healthcare products and associated radiation risks
description Investigation is made of 23 commercially available tourmaline-based healthcare products containing naturally occurring radioactive material (the products including hot spa stones, face masks, waist supporter slimming belts, arm relief belts, socks, insoles, soaps, and combs) with negative ion health benefits claimed by the purveyors. Assessment is made of the radiological risk posed by the use of such products, external exposure dose being the particular focus. Gamma spectroscopy analysis and Geant4 Monte Carlo (GMC) simulations are used. Organ doses are obtained using male and female human phantoms, dose conversion factors (DCFs) being included. For 238U and 232tTh the tourmaline sock, code T20 was found to contain the greatest activity, at 2.4 ± 0.2 and 28.0 ± 1.3 Bq g ̶ 1 respectively; least was for the magnetic therapy face mask, code T02, at respective values 0.04 ± 0.01 and 0.1 ± 0.01 Bq g ̶ 1. Across all of the tourmaline products, the 4 K range was 0.16 ± 0.01–16.4 ± 1.1 Bq g ̶ 1. In terms of elemental concentration, sample T20 offered the greatest concentration, with mean percentages of 0.022 ± 0.001 and 0.78 ± 0.10, for Th and U, respectively. With the assumption of exposure for a period of 8 h per day, wearing the tourmaline sock product T20 would give rise to an annual effective dose of 0.64 mSv, less than the public annual dose limit of 1 mSv. Noting that the samples may give rise to greater doses, national screening programmes for activity are suggested in seeking to mitigate unnecessary radiation exposure.
format Article
author Hassan, Halmat Jalal
Hashim, Suhairul
Abu Hanifah, N. Z. H.
Mohd. Sanusi, Mohammad Syazwan
Fahmi, M. R.
Mohd. Tahar, Rozman
Bradley, David A.
author_facet Hassan, Halmat Jalal
Hashim, Suhairul
Abu Hanifah, N. Z. H.
Mohd. Sanusi, Mohammad Syazwan
Fahmi, M. R.
Mohd. Tahar, Rozman
Bradley, David A.
author_sort Hassan, Halmat Jalal
title Use of tourmaline-based healthcare products and associated radiation risks
title_short Use of tourmaline-based healthcare products and associated radiation risks
title_full Use of tourmaline-based healthcare products and associated radiation risks
title_fullStr Use of tourmaline-based healthcare products and associated radiation risks
title_full_unstemmed Use of tourmaline-based healthcare products and associated radiation risks
title_sort use of tourmaline-based healthcare products and associated radiation risks
publisher Elsevier Ltd
publishDate 2022
url http://eprints.utm.my/103905/
http://dx.doi.org/10.1016/j.radphyschem.2022.110276
_version_ 1784511520341753856
score 13.211869