Numerical investigation on cooling performance of oil cooled PMSM jacket design with vertical straight fin design
Cooling has been an important parameter to extend the high-speed generator operating conditions. Literature highlights the high speed generator jacketjacket of generator is a crucial part that need to be cooled down to dissipate the coil temperature to ensure the performance of the Permanent magnet...