Investigation on Mechanical Strengths and Carbon Foot Print of Modified Foamed Concrete
This paper describes the work of a study carried out to investigate the mechanical strengths and carbon foot print of foamed concrete incorporating with local industrial wastes. Experiments were performed to obtain a minimum 28 days compressive strength of 15 MPa modified foamed concretes by using...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
uthm
2023
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/9543/1/J16072_d54da97991edc537ca4b16b6c1c4e22e.pdf http://eprints.uthm.edu.my/9543/ https://doi.org/10.30880/ijscet.2023.14.02.004 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uthm.eprints.9543 |
---|---|
record_format |
eprints |
spelling |
my.uthm.eprints.95432023-08-02T03:48:41Z http://eprints.uthm.edu.my/9543/ Investigation on Mechanical Strengths and Carbon Foot Print of Modified Foamed Concrete Koh Heng Boon, Koh Heng Boon Mohd Jaini, Zainorizuan Tan Tee How, Tan Tee How T Technology (General) This paper describes the work of a study carried out to investigate the mechanical strengths and carbon foot print of foamed concrete incorporating with local industrial wastes. Experiments were performed to obtain a minimum 28 days compressive strength of 15 MPa modified foamed concretes by using palm oil fuel ash (POFA) and fly ash (FA) as partial cement replacement and unprocessed rush husk ash (RHA) as partial fine aggregate replacement. Carbon footprint analysis was carried out by determining the CO2 emission for each constituent materials in the modified foamed concrete mixes. Although incorporation of POFA in the foamed concrete containing RHA fine aggregate gained lower mechanical strengths compared to the use of FA, the minimum compressive strength is still can be attained. In terms of the sustainability, modified foamed concrete with 30% POFA or 30% FA was found an encouraging reduction of carbon foot print up to about 30% compared to the control foamed concrete. Based on eco-strength indicator, the optimum foamed concrete mix with POFA was found to be at 22.5% cement replacement level. The eco-modified foamed concrete has good potential in civil engineering construction and environmentally friendly. uthm 2023 Article PeerReviewed text en http://eprints.uthm.edu.my/9543/1/J16072_d54da97991edc537ca4b16b6c1c4e22e.pdf Koh Heng Boon, Koh Heng Boon and Mohd Jaini, Zainorizuan and Tan Tee How, Tan Tee How (2023) Investigation on Mechanical Strengths and Carbon Foot Print of Modified Foamed Concrete. INTERNATIONAL JOURNAL OF SUSTAINABLE CONSTRUCTION ENGINEERING AND TECHNOLOGY, 14 (2). pp. 31-40. ISSN 2180-3242 https://doi.org/10.30880/ijscet.2023.14.02.004 |
institution |
Universiti Tun Hussein Onn Malaysia |
building |
UTHM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tun Hussein Onn Malaysia |
content_source |
UTHM Institutional Repository |
url_provider |
http://eprints.uthm.edu.my/ |
language |
English |
topic |
T Technology (General) |
spellingShingle |
T Technology (General) Koh Heng Boon, Koh Heng Boon Mohd Jaini, Zainorizuan Tan Tee How, Tan Tee How Investigation on Mechanical Strengths and Carbon Foot Print of Modified Foamed Concrete |
description |
This paper describes the work of a study carried out to investigate the mechanical strengths and carbon
foot print of foamed concrete incorporating with local industrial wastes. Experiments were performed to obtain a
minimum 28 days compressive strength of 15 MPa modified foamed concretes by using palm oil fuel ash (POFA)
and fly ash (FA) as partial cement replacement and unprocessed rush husk ash (RHA) as partial fine aggregate
replacement. Carbon footprint analysis was carried out by determining the CO2 emission for each constituent
materials in the modified foamed concrete mixes. Although incorporation of POFA in the foamed concrete
containing RHA fine aggregate gained lower mechanical strengths compared to the use of FA, the minimum
compressive strength is still can be attained. In terms of the sustainability, modified foamed concrete with 30%
POFA or 30% FA was found an encouraging reduction of carbon foot print up to about 30% compared to the
control foamed concrete. Based on eco-strength indicator, the optimum foamed concrete mix with POFA was
found to be at 22.5% cement replacement level. The eco-modified foamed concrete has good potential in civil
engineering construction and environmentally friendly. |
format |
Article |
author |
Koh Heng Boon, Koh Heng Boon Mohd Jaini, Zainorizuan Tan Tee How, Tan Tee How |
author_facet |
Koh Heng Boon, Koh Heng Boon Mohd Jaini, Zainorizuan Tan Tee How, Tan Tee How |
author_sort |
Koh Heng Boon, Koh Heng Boon |
title |
Investigation on Mechanical Strengths and Carbon Foot Print
of Modified Foamed Concrete |
title_short |
Investigation on Mechanical Strengths and Carbon Foot Print
of Modified Foamed Concrete |
title_full |
Investigation on Mechanical Strengths and Carbon Foot Print
of Modified Foamed Concrete |
title_fullStr |
Investigation on Mechanical Strengths and Carbon Foot Print
of Modified Foamed Concrete |
title_full_unstemmed |
Investigation on Mechanical Strengths and Carbon Foot Print
of Modified Foamed Concrete |
title_sort |
investigation on mechanical strengths and carbon foot print
of modified foamed concrete |
publisher |
uthm |
publishDate |
2023 |
url |
http://eprints.uthm.edu.my/9543/1/J16072_d54da97991edc537ca4b16b6c1c4e22e.pdf http://eprints.uthm.edu.my/9543/ https://doi.org/10.30880/ijscet.2023.14.02.004 |
_version_ |
1773545915295989760 |
score |
13.211869 |