Planar Edged UWB Antenna for Water Quality Measurement

—A compact planar edge ultra-wideband (UWB) antenna is designed to operate at a frequency range of 3.5 GHz to 10.4 GHz for water quality detection. The design was constructed on an FR4 substrate with an overall dimension of 30 × 35 × 1.6 mm3 . The presented design is used to detect the presence of s...

Full description

Saved in:
Bibliographic Details
Main Authors: Joseph Charles Vinoth, Joseph Charles Vinoth, Subramaniam Ramesh, Subramaniam Ramesh, Zuhairiah Z. Abidin, Zuhairiah Z. Abidin, Suhail A. Qureshi, Suhail A. Qureshi, Sivathanu Chitra, Sivathanu Chitra, Elumalai Saranya, Elumalai Saranya
Format: Article
Language:English
English
Published: 2023
Subjects:
Online Access:http://eprints.uthm.edu.my/8905/1/J15831_8ffcb2abc80cdc8ff624a98646c035bb.pdf
http://eprints.uthm.edu.my/8905/2/J15831_8ffcb2abc80cdc8ff624a98646c035bb.pdf
http://eprints.uthm.edu.my/8905/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.8905
record_format eprints
spelling my.uthm.eprints.89052023-06-18T01:34:31Z http://eprints.uthm.edu.my/8905/ Planar Edged UWB Antenna for Water Quality Measurement Joseph Charles Vinoth, Joseph Charles Vinoth Subramaniam Ramesh, Subramaniam Ramesh Zuhairiah Z. Abidin, Zuhairiah Z. Abidin Suhail A. Qureshi, Suhail A. Qureshi Sivathanu Chitra, Sivathanu Chitra Elumalai Saranya, Elumalai Saranya T Technology (General) —A compact planar edge ultra-wideband (UWB) antenna is designed to operate at a frequency range of 3.5 GHz to 10.4 GHz for water quality detection. The design was constructed on an FR4 substrate with an overall dimension of 30 × 35 × 1.6 mm3 . The presented design is used to detect the presence of salt in the water in terms of reflection coefficient (S11). The proposed antenna’s performance was examined by increasing the salinity of the three water samples: distilled water, reverse osmosis (RO), and raw water. The results showed the decrease of the S11 with the increment of salt in the water samples. In addition, the antenna showed good sensitivity as the resonance frequency of the antenna slightly shifted to a lower frequency as the dielectric constant of water increased. Hence, the proposed UWB antenna can be prominently suitable for monitoring water quality and sensors. 2023 Article PeerReviewed text en http://eprints.uthm.edu.my/8905/1/J15831_8ffcb2abc80cdc8ff624a98646c035bb.pdf text en http://eprints.uthm.edu.my/8905/2/J15831_8ffcb2abc80cdc8ff624a98646c035bb.pdf Joseph Charles Vinoth, Joseph Charles Vinoth and Subramaniam Ramesh, Subramaniam Ramesh and Zuhairiah Z. Abidin, Zuhairiah Z. Abidin and Suhail A. Qureshi, Suhail A. Qureshi and Sivathanu Chitra, Sivathanu Chitra and Elumalai Saranya, Elumalai Saranya (2023) Planar Edged UWB Antenna for Water Quality Measurement. Progress In Electromagnetics Research, 130. pp. 83-93.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
English
topic T Technology (General)
spellingShingle T Technology (General)
Joseph Charles Vinoth, Joseph Charles Vinoth
Subramaniam Ramesh, Subramaniam Ramesh
Zuhairiah Z. Abidin, Zuhairiah Z. Abidin
Suhail A. Qureshi, Suhail A. Qureshi
Sivathanu Chitra, Sivathanu Chitra
Elumalai Saranya, Elumalai Saranya
Planar Edged UWB Antenna for Water Quality Measurement
description —A compact planar edge ultra-wideband (UWB) antenna is designed to operate at a frequency range of 3.5 GHz to 10.4 GHz for water quality detection. The design was constructed on an FR4 substrate with an overall dimension of 30 × 35 × 1.6 mm3 . The presented design is used to detect the presence of salt in the water in terms of reflection coefficient (S11). The proposed antenna’s performance was examined by increasing the salinity of the three water samples: distilled water, reverse osmosis (RO), and raw water. The results showed the decrease of the S11 with the increment of salt in the water samples. In addition, the antenna showed good sensitivity as the resonance frequency of the antenna slightly shifted to a lower frequency as the dielectric constant of water increased. Hence, the proposed UWB antenna can be prominently suitable for monitoring water quality and sensors.
format Article
author Joseph Charles Vinoth, Joseph Charles Vinoth
Subramaniam Ramesh, Subramaniam Ramesh
Zuhairiah Z. Abidin, Zuhairiah Z. Abidin
Suhail A. Qureshi, Suhail A. Qureshi
Sivathanu Chitra, Sivathanu Chitra
Elumalai Saranya, Elumalai Saranya
author_facet Joseph Charles Vinoth, Joseph Charles Vinoth
Subramaniam Ramesh, Subramaniam Ramesh
Zuhairiah Z. Abidin, Zuhairiah Z. Abidin
Suhail A. Qureshi, Suhail A. Qureshi
Sivathanu Chitra, Sivathanu Chitra
Elumalai Saranya, Elumalai Saranya
author_sort Joseph Charles Vinoth, Joseph Charles Vinoth
title Planar Edged UWB Antenna for Water Quality Measurement
title_short Planar Edged UWB Antenna for Water Quality Measurement
title_full Planar Edged UWB Antenna for Water Quality Measurement
title_fullStr Planar Edged UWB Antenna for Water Quality Measurement
title_full_unstemmed Planar Edged UWB Antenna for Water Quality Measurement
title_sort planar edged uwb antenna for water quality measurement
publishDate 2023
url http://eprints.uthm.edu.my/8905/1/J15831_8ffcb2abc80cdc8ff624a98646c035bb.pdf
http://eprints.uthm.edu.my/8905/2/J15831_8ffcb2abc80cdc8ff624a98646c035bb.pdf
http://eprints.uthm.edu.my/8905/
_version_ 1769845111116529664
score 13.211869