Fractional electro-magneto transport of blood modeled with magnetic particles in cylindrical tube without singular kernel

The electro-kinetic transport of blood flow mixed with magnetic particles in the circular channel was investigated. The flow was subjected to an external electric and uniform magnetic field. The fluid was driven by pressure gradient and perpendicular magnetic field to the flow direction. Due to th...

Full description

Saved in:
Bibliographic Details
Main Authors: Uddin, S., Mohamad, M., Gorji, Mohammad Rahimi, Roslan, R., M. Alarifi, Ibrahim
Format: Article
Language:English
Published: Springer 2020
Subjects:
Online Access:http://eprints.uthm.edu.my/875/1/DNJ9857_6b006565c8badcb5514b58ef4b9e46b1.pdf
http://eprints.uthm.edu.my/875/
https://doi.org/10.1007/s00542-019-04494-0
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.875
record_format eprints
spelling my.uthm.eprints.8752021-10-17T07:06:27Z http://eprints.uthm.edu.my/875/ Fractional electro-magneto transport of blood modeled with magnetic particles in cylindrical tube without singular kernel Uddin, S. Mohamad, M. Gorji, Mohammad Rahimi Roslan, R. M. Alarifi, Ibrahim QA71-90 Instruments and machines The electro-kinetic transport of blood flow mixed with magnetic particles in the circular channel was investigated. The flow was subjected to an external electric and uniform magnetic field. The fluid was driven by pressure gradient and perpendicular magnetic field to the flow direction. Due to the usefulness and suitability of Caputo–Fabrizio fractional order derivative without singular kernel in fluid flow modeling and mass transfer phenomena, the governing equations were modeled as Caputo–Fabrizio time fractional partial differential equations and solved for a 2 ð0; 1�. The analytical solutions for the velocities of blood flow and magnetic particles were obtained by using Laplace, finite Hankel transforms and Robotnov and Hartley’s functions, respectively. Mathematica software was used to simulate the influences of fractional parameter a, Hartmann number and Reynolds number on the velocities of blood and magnetic particles. The findings are important for controlling bio-liquids in the devices used for analysis and diagnosis in biological and medical applications. Springer 2020 Article PeerReviewed text en http://eprints.uthm.edu.my/875/1/DNJ9857_6b006565c8badcb5514b58ef4b9e46b1.pdf Uddin, S. and Mohamad, M. and Gorji, Mohammad Rahimi and Roslan, R. and M. Alarifi, Ibrahim (2020) Fractional electro-magneto transport of blood modeled with magnetic particles in cylindrical tube without singular kernel. Microsystem Technologies, 26. pp. 405-414. https://doi.org/10.1007/s00542-019-04494-0
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic QA71-90 Instruments and machines
spellingShingle QA71-90 Instruments and machines
Uddin, S.
Mohamad, M.
Gorji, Mohammad Rahimi
Roslan, R.
M. Alarifi, Ibrahim
Fractional electro-magneto transport of blood modeled with magnetic particles in cylindrical tube without singular kernel
description The electro-kinetic transport of blood flow mixed with magnetic particles in the circular channel was investigated. The flow was subjected to an external electric and uniform magnetic field. The fluid was driven by pressure gradient and perpendicular magnetic field to the flow direction. Due to the usefulness and suitability of Caputo–Fabrizio fractional order derivative without singular kernel in fluid flow modeling and mass transfer phenomena, the governing equations were modeled as Caputo–Fabrizio time fractional partial differential equations and solved for a 2 ð0; 1�. The analytical solutions for the velocities of blood flow and magnetic particles were obtained by using Laplace, finite Hankel transforms and Robotnov and Hartley’s functions, respectively. Mathematica software was used to simulate the influences of fractional parameter a, Hartmann number and Reynolds number on the velocities of blood and magnetic particles. The findings are important for controlling bio-liquids in the devices used for analysis and diagnosis in biological and medical applications.
format Article
author Uddin, S.
Mohamad, M.
Gorji, Mohammad Rahimi
Roslan, R.
M. Alarifi, Ibrahim
author_facet Uddin, S.
Mohamad, M.
Gorji, Mohammad Rahimi
Roslan, R.
M. Alarifi, Ibrahim
author_sort Uddin, S.
title Fractional electro-magneto transport of blood modeled with magnetic particles in cylindrical tube without singular kernel
title_short Fractional electro-magneto transport of blood modeled with magnetic particles in cylindrical tube without singular kernel
title_full Fractional electro-magneto transport of blood modeled with magnetic particles in cylindrical tube without singular kernel
title_fullStr Fractional electro-magneto transport of blood modeled with magnetic particles in cylindrical tube without singular kernel
title_full_unstemmed Fractional electro-magneto transport of blood modeled with magnetic particles in cylindrical tube without singular kernel
title_sort fractional electro-magneto transport of blood modeled with magnetic particles in cylindrical tube without singular kernel
publisher Springer
publishDate 2020
url http://eprints.uthm.edu.my/875/1/DNJ9857_6b006565c8badcb5514b58ef4b9e46b1.pdf
http://eprints.uthm.edu.my/875/
https://doi.org/10.1007/s00542-019-04494-0
_version_ 1738580793679151104
score 13.211869