Potentials of energy efficiency in a public hospital: a case Study in Hospital Kajang

Hospitals are known to be one of the largest energy consumers as they continuously provide healthcare services to the community on a daily basis. This thesis reports a case study carried in one of the public hospitals in Malaysia - Hospital Kajang, as an effort to gather and disseminate more info...

Full description

Saved in:
Bibliographic Details
Main Author: Samsudin, Sheikh Saiful Azam
Format: Thesis
Language:English
English
English
Published: 2022
Subjects:
Online Access:http://eprints.uthm.edu.my/8347/2/24p%20SHEIKH%20SAIFUL%20AZAM%20SAMSUDIN.pdf
http://eprints.uthm.edu.my/8347/1/SHEIKH%20SAIFUL%20AZAM%20SAMSUDIN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/8347/3/SHEIKH%20SAIFUL%20AZAM%20SAMSUDIN%20WATERMARK.pdf
http://eprints.uthm.edu.my/8347/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.8347
record_format eprints
spelling my.uthm.eprints.83472023-02-15T07:20:33Z http://eprints.uthm.edu.my/8347/ Potentials of energy efficiency in a public hospital: a case Study in Hospital Kajang Samsudin, Sheikh Saiful Azam H Social Sciences (General) Hospitals are known to be one of the largest energy consumers as they continuously provide healthcare services to the community on a daily basis. This thesis reports a case study carried in one of the public hospitals in Malaysia - Hospital Kajang, as an effort to gather and disseminate more information regarding energy efficiency opportunities in hospitals which will benefit the hospital management as well as the public. The study was carried out via walk-through audit and desktop analysis, followed by a detailed energy audit to identify the electrical energy consumption pattern, factors that affect the energy usage and end-use energy analysis based on different categories namely air conditioning and mechanical ventilation system, lighting system, medical equipment, IT equipment and peripherals and other electrical equipment. Malaysian Standard MS 1525:2019 was used in this study for evaluating the indoor environment quality as well as lighting to ensure energy efficiency will not affect these requirements. From the study, it was found that the largest electrical energy end-user in Hospital Kajang is the air conditioning and mechanical ventilation system, which consumes approximately 78% of the total electrical energy. The building energy index calculation revealed that the hospital building has an index of 302.32 kWh/m2/year for the year 2019 which is significantly higher than the benchmark value of 200 kWh/m2/year for office buildings. A number of energy efficiency measures were proposed to reduce energy consumption in Hospital Kajang, together with their respective economic analysis. 2022-06 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/8347/2/24p%20SHEIKH%20SAIFUL%20AZAM%20SAMSUDIN.pdf text en http://eprints.uthm.edu.my/8347/1/SHEIKH%20SAIFUL%20AZAM%20SAMSUDIN%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/8347/3/SHEIKH%20SAIFUL%20AZAM%20SAMSUDIN%20WATERMARK.pdf Samsudin, Sheikh Saiful Azam (2022) Potentials of energy efficiency in a public hospital: a case Study in Hospital Kajang. Masters thesis, Universiti Tun Hussein Onn Malaysia.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
English
English
topic H Social Sciences (General)
spellingShingle H Social Sciences (General)
Samsudin, Sheikh Saiful Azam
Potentials of energy efficiency in a public hospital: a case Study in Hospital Kajang
description Hospitals are known to be one of the largest energy consumers as they continuously provide healthcare services to the community on a daily basis. This thesis reports a case study carried in one of the public hospitals in Malaysia - Hospital Kajang, as an effort to gather and disseminate more information regarding energy efficiency opportunities in hospitals which will benefit the hospital management as well as the public. The study was carried out via walk-through audit and desktop analysis, followed by a detailed energy audit to identify the electrical energy consumption pattern, factors that affect the energy usage and end-use energy analysis based on different categories namely air conditioning and mechanical ventilation system, lighting system, medical equipment, IT equipment and peripherals and other electrical equipment. Malaysian Standard MS 1525:2019 was used in this study for evaluating the indoor environment quality as well as lighting to ensure energy efficiency will not affect these requirements. From the study, it was found that the largest electrical energy end-user in Hospital Kajang is the air conditioning and mechanical ventilation system, which consumes approximately 78% of the total electrical energy. The building energy index calculation revealed that the hospital building has an index of 302.32 kWh/m2/year for the year 2019 which is significantly higher than the benchmark value of 200 kWh/m2/year for office buildings. A number of energy efficiency measures were proposed to reduce energy consumption in Hospital Kajang, together with their respective economic analysis.
format Thesis
author Samsudin, Sheikh Saiful Azam
author_facet Samsudin, Sheikh Saiful Azam
author_sort Samsudin, Sheikh Saiful Azam
title Potentials of energy efficiency in a public hospital: a case Study in Hospital Kajang
title_short Potentials of energy efficiency in a public hospital: a case Study in Hospital Kajang
title_full Potentials of energy efficiency in a public hospital: a case Study in Hospital Kajang
title_fullStr Potentials of energy efficiency in a public hospital: a case Study in Hospital Kajang
title_full_unstemmed Potentials of energy efficiency in a public hospital: a case Study in Hospital Kajang
title_sort potentials of energy efficiency in a public hospital: a case study in hospital kajang
publishDate 2022
url http://eprints.uthm.edu.my/8347/2/24p%20SHEIKH%20SAIFUL%20AZAM%20SAMSUDIN.pdf
http://eprints.uthm.edu.my/8347/1/SHEIKH%20SAIFUL%20AZAM%20SAMSUDIN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/8347/3/SHEIKH%20SAIFUL%20AZAM%20SAMSUDIN%20WATERMARK.pdf
http://eprints.uthm.edu.my/8347/
_version_ 1758580275365806080
score 13.211869