Effects of geometrical parameters to the performance of louvered fin heat exchangers
Numerical study using ANSYS Fluent is conducted to investigate the effects of louver angle on pressure drop and heat transfer of a heat exchanger. Flow simulations are conducted on 3D modeling of multi stacks louvered fins at three different parameters of louver angles which are 22.0º, 25.5º and 29....
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Trans Tech Publications
2015
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/5785/1/AJ%202015%20%2850%29.pdf http://eprints.uthm.edu.my/5785/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uthm.eprints.5785 |
---|---|
record_format |
eprints |
spelling |
my.uthm.eprints.57852022-01-23T06:49:03Z http://eprints.uthm.edu.my/5785/ Effects of geometrical parameters to the performance of louvered fin heat exchangers Md Seri, Suzairin Amirnordin, Shahrin Hisham Woon, Qiu Yik Hissein Didane, Djamal TJ255-265 Heat engines Numerical study using ANSYS Fluent is conducted to investigate the effects of louver angle on pressure drop and heat transfer of a heat exchanger. Flow simulations are conducted on 3D modeling of multi stacks louvered fins at three different parameters of louver angles which are 22.0º, 25.5º and 29.0º with Reynolds number ranging from 200 to 1000. These Reynolds numbers are based on louver pitch and fin pitch. The flow temperature is set at 300K which is the room temperature, while temperature of louver fin is set at 400K. The results show that Reynolds number based on fin pitch 2.02 mm and louver angle of 22.0º generate higher performance of heat exchanger compared to louver pitch of 1.40 mm and the other louver angles. Therefore, configuration of Reynolds number based on fin pitch 2.02 mm and louver angle 22.0º is preferred to be adopted in the design process of heat exchanger. Trans Tech Publications 2015 Article PeerReviewed text en http://eprints.uthm.edu.my/5785/1/AJ%202015%20%2850%29.pdf Md Seri, Suzairin and Amirnordin, Shahrin Hisham and Woon, Qiu Yik and Hissein Didane, Djamal (2015) Effects of geometrical parameters to the performance of louvered fin heat exchangers. Applied Mechanics and Materials, 773-77. p. 398. ISSN 1660-9336 |
institution |
Universiti Tun Hussein Onn Malaysia |
building |
UTHM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tun Hussein Onn Malaysia |
content_source |
UTHM Institutional Repository |
url_provider |
http://eprints.uthm.edu.my/ |
language |
English |
topic |
TJ255-265 Heat engines |
spellingShingle |
TJ255-265 Heat engines Md Seri, Suzairin Amirnordin, Shahrin Hisham Woon, Qiu Yik Hissein Didane, Djamal Effects of geometrical parameters to the performance of louvered fin heat exchangers |
description |
Numerical study using ANSYS Fluent is conducted to investigate the effects of louver angle on pressure drop and heat transfer of a heat exchanger. Flow simulations are conducted on 3D modeling of multi stacks louvered fins at three different parameters of louver angles which are 22.0º, 25.5º and 29.0º with Reynolds number ranging from 200 to 1000. These Reynolds numbers are based on louver pitch and fin pitch. The flow temperature is set at 300K which is the room temperature, while temperature of louver fin is set at 400K. The results show that Reynolds number based on fin pitch 2.02 mm and louver angle of 22.0º generate higher performance of heat exchanger compared to louver pitch of 1.40 mm and the other louver angles. Therefore, configuration of Reynolds number based on fin pitch 2.02 mm and louver angle 22.0º is preferred to be adopted in the design process of heat exchanger. |
format |
Article |
author |
Md Seri, Suzairin Amirnordin, Shahrin Hisham Woon, Qiu Yik Hissein Didane, Djamal |
author_facet |
Md Seri, Suzairin Amirnordin, Shahrin Hisham Woon, Qiu Yik Hissein Didane, Djamal |
author_sort |
Md Seri, Suzairin |
title |
Effects of geometrical parameters to the performance of louvered fin heat exchangers |
title_short |
Effects of geometrical parameters to the performance of louvered fin heat exchangers |
title_full |
Effects of geometrical parameters to the performance of louvered fin heat exchangers |
title_fullStr |
Effects of geometrical parameters to the performance of louvered fin heat exchangers |
title_full_unstemmed |
Effects of geometrical parameters to the performance of louvered fin heat exchangers |
title_sort |
effects of geometrical parameters to the performance of louvered fin heat exchangers |
publisher |
Trans Tech Publications |
publishDate |
2015 |
url |
http://eprints.uthm.edu.my/5785/1/AJ%202015%20%2850%29.pdf http://eprints.uthm.edu.my/5785/ |
_version_ |
1738581414870253568 |
score |
13.244745 |