High temperature fatigue characteristics of P/M and hot-forgedW-Re and TZM for X-ray target of CT scanner

The fatigue strengths at 1000 °C of layeredW-Re/TZM, bulkW-Re and bulk TZM for x-ray target materials were successfully evaluated under load-controlled four-point bending by introducing a fatigue failure criterion as twotimes increase of initial compliance. The obtained fatigue strengths at 1000 °C...

Full description

Saved in:
Bibliographic Details
Main Authors: Harimon, Mohd Azhar, Miyashita, Yukio, Otsuka, Yuichi, Mutoh, Yoshiharu, Yamamoto, Shinichi
Format: Article
Language:English
Published: Elsevier 2018
Subjects:
Online Access:http://eprints.uthm.edu.my/5224/1/AJ%202020%20%28101%29.pdf
http://eprints.uthm.edu.my/5224/
https://doi.org/10.1016/j.matdes.2017.10.044