Single phase inverter system using proportional resonant current control

This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in s...

詳細記述

保存先:
書誌詳細
主要な著者: Chen, K.C., Salimin, Suriana, Zulkifli, S. A., Aziz, Rebaz
フォーマット: 論文
出版事項: Institute of Advanced Engineering and Science (IAES) 2017
主題:
オンライン・アクセス:http://eprints.uthm.edu.my/3975/
https://dx.doi.org/10.11591/ijpeds.v8.i4.pp1913-1918
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
その他の書誌記述
要約:This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in single phase inverter system. The potential of nonlinear load in producing harmonics is showed and identified by developing a nonlinear load model using a full bridge rectifier circuit. The modelling and simulation is done in MATLAB Simulink while harmonic spectrum results are obtained using Fast Fourier Transfor. End result show PR current controller capability to overcome the injection of current harmonic problems thus improved the overall total harmonic distortion (THD).