The impact of fault current limiter in power system performance
Continues growth of electrical energy demand is resulting in a corresponding increase in the short circuit in power system. Several solutions have been implemented, including the use of Fault Current Limiter (FCL), in order to reduce circuit breakers rated capacity and to limit the electromagneti...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2009
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/3965/1/24p%20MOHD%20AIFAA%20MOHD%20ARIFF.pdf http://eprints.uthm.edu.my/3965/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uthm.eprints.3965 |
---|---|
record_format |
eprints |
spelling |
my.uthm.eprints.39652022-02-03T02:13:01Z http://eprints.uthm.edu.my/3965/ The impact of fault current limiter in power system performance Mohd Ariff, Mohd Aifaa TK Electrical engineering. Electronics Nuclear engineering TK1001-1841 Production of electric energy or power. Powerplants. Central stations Continues growth of electrical energy demand is resulting in a corresponding increase in the short circuit in power system. Several solutions have been implemented, including the use of Fault Current Limiter (FCL), in order to reduce circuit breakers rated capacity and to limit the electromagnetics stress in associated equipment. This project presents a comprehensive study of the impact of fault current limiter in power system performance. The FCL use for this study is solid-state type because it has advantages in term of flexibility and control over superconducting type. In order to evaluate the impact of fault current limiter in power system performance, simulation model of power system performance with solid-state FCL are used. For simulation model development, MATLAB Simulation Tools: SIMULINK software is used. A distribution system fed from single source is used to assess the impact of FCL to power system performance. The FCL is evaluated in term of its performance in limiting fault current from about 50 kA to a lower value of 1.7 kA. Results show that the solid-state FCL is effective for reducing short circuit currents up to 98% and also can be used to protect busbars from voltage sag when the system is subjected to various types of faults. 2009-11 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/3965/1/24p%20MOHD%20AIFAA%20MOHD%20ARIFF.pdf Mohd Ariff, Mohd Aifaa (2009) The impact of fault current limiter in power system performance. Masters thesis, Universiti Teknologi Malaysia.. |
institution |
Universiti Tun Hussein Onn Malaysia |
building |
UTHM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tun Hussein Onn Malaysia |
content_source |
UTHM Institutional Repository |
url_provider |
http://eprints.uthm.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering TK1001-1841 Production of electric energy or power. Powerplants. Central stations |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering TK1001-1841 Production of electric energy or power. Powerplants. Central stations Mohd Ariff, Mohd Aifaa The impact of fault current limiter in power system performance |
description |
Continues growth of electrical energy demand is resulting in a corresponding
increase in the short circuit in power system. Several solutions have been
implemented, including the use of Fault Current Limiter (FCL), in order to reduce
circuit breakers rated capacity and to limit the electromagnetics stress in associated
equipment. This project presents a comprehensive study of the impact of fault current
limiter in power system performance. The FCL use for this study is solid-state type
because it has advantages in term of flexibility and control over superconducting
type. In order to evaluate the impact of fault current limiter in power system
performance, simulation model of power system performance with solid-state FCL
are used. For simulation model development, MATLAB Simulation Tools:
SIMULINK software is used. A distribution system fed from single source is used to
assess the impact of FCL to power system performance. The FCL is evaluated in
term of its performance in limiting fault current from about 50 kA to a lower value of
1.7 kA. Results show that the solid-state FCL is effective for reducing short circuit
currents up to 98% and also can be used to protect busbars from voltage sag when
the system is subjected to various types of faults. |
format |
Thesis |
author |
Mohd Ariff, Mohd Aifaa |
author_facet |
Mohd Ariff, Mohd Aifaa |
author_sort |
Mohd Ariff, Mohd Aifaa |
title |
The impact of fault current limiter in power system performance |
title_short |
The impact of fault current limiter in power system performance |
title_full |
The impact of fault current limiter in power system performance |
title_fullStr |
The impact of fault current limiter in power system performance |
title_full_unstemmed |
The impact of fault current limiter in power system performance |
title_sort |
impact of fault current limiter in power system performance |
publishDate |
2009 |
url |
http://eprints.uthm.edu.my/3965/1/24p%20MOHD%20AIFAA%20MOHD%20ARIFF.pdf http://eprints.uthm.edu.my/3965/ |
_version_ |
1738581188918902784 |
score |
13.211869 |