The THD performance of single phase five level inverter using pr and harmonic compensators current controller

Iniorderitoimeetitheirequirementifromitheiindustriesidemandiaimediatiaifree-harmonicsiand highipoweriratingisourceiisiremarkablyiincreasediinipastifewiyears.iAsicompareditoisingleleveliinverter,imultileveliinverterioffersiminimumiharmonicidistortioniandihigheripower output. This project is to observ...

Full description

Saved in:
Bibliographic Details
Main Author: Abdullahi, Abdullahi Mohamed
Format: Thesis
Language:English
English
English
Published: 2020
Subjects:
Online Access:http://eprints.uthm.edu.my/377/1/24p%20ABDULLAHI%20MOHAMED%20ABDULLAHI.pdf
http://eprints.uthm.edu.my/377/2/ABDULLAHI%20MOHAMED%20ABDULLAHI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/377/3/ABDULLAHI%20MOHAMED%20ABDULLAHI%20WATERMARK.pdf
http://eprints.uthm.edu.my/377/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.377
record_format eprints
spelling my.uthm.eprints.3772021-07-25T01:13:05Z http://eprints.uthm.edu.my/377/ The THD performance of single phase five level inverter using pr and harmonic compensators current controller Abdullahi, Abdullahi Mohamed TK7800-8360 Electronics Iniorderitoimeetitheirequirementifromitheiindustriesidemandiaimediatiaifree-harmonicsiand highipoweriratingisourceiisiremarkablyiincreasediinipastifewiyears.iAsicompareditoisingleleveliinverter,imultileveliinverterioffersiminimumiharmonicidistortioniandihigheripower output. This project is to observe the THD performance of single phase five level inverter using proportional resonant (PR) and harmonic compensators current controller. The PR controller not only solve the current and harmonic problem, but also efficiency and accuracy of equipment in other application. The THD was reduced to 1.6% which is in the scope of the project. More functions were added to the PR current controller to reduce the THD at the 3th, 5th, and 7th, harmonic orders. The THD of the 3th, harmonic order was reduced from 0.45% to 0.1% while the, 5th, and 7th, harmonic orders were reduced from 0.6% and 0.43% to 0.25% and 0.4% respectively. The development and simulation is performed using Matlab/Simulink. The simulation result of experiment is performed by using Fast Fourier Transform analysis (FFT) for the harmonics captured. 2020-01 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/377/1/24p%20ABDULLAHI%20MOHAMED%20ABDULLAHI.pdf text en http://eprints.uthm.edu.my/377/2/ABDULLAHI%20MOHAMED%20ABDULLAHI%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/377/3/ABDULLAHI%20MOHAMED%20ABDULLAHI%20WATERMARK.pdf Abdullahi, Abdullahi Mohamed (2020) The THD performance of single phase five level inverter using pr and harmonic compensators current controller. Masters thesis, Universiti Tun Hussein Onn Malaysia.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
English
English
topic TK7800-8360 Electronics
spellingShingle TK7800-8360 Electronics
Abdullahi, Abdullahi Mohamed
The THD performance of single phase five level inverter using pr and harmonic compensators current controller
description Iniorderitoimeetitheirequirementifromitheiindustriesidemandiaimediatiaifree-harmonicsiand highipoweriratingisourceiisiremarkablyiincreasediinipastifewiyears.iAsicompareditoisingleleveliinverter,imultileveliinverterioffersiminimumiharmonicidistortioniandihigheripower output. This project is to observe the THD performance of single phase five level inverter using proportional resonant (PR) and harmonic compensators current controller. The PR controller not only solve the current and harmonic problem, but also efficiency and accuracy of equipment in other application. The THD was reduced to 1.6% which is in the scope of the project. More functions were added to the PR current controller to reduce the THD at the 3th, 5th, and 7th, harmonic orders. The THD of the 3th, harmonic order was reduced from 0.45% to 0.1% while the, 5th, and 7th, harmonic orders were reduced from 0.6% and 0.43% to 0.25% and 0.4% respectively. The development and simulation is performed using Matlab/Simulink. The simulation result of experiment is performed by using Fast Fourier Transform analysis (FFT) for the harmonics captured.
format Thesis
author Abdullahi, Abdullahi Mohamed
author_facet Abdullahi, Abdullahi Mohamed
author_sort Abdullahi, Abdullahi Mohamed
title The THD performance of single phase five level inverter using pr and harmonic compensators current controller
title_short The THD performance of single phase five level inverter using pr and harmonic compensators current controller
title_full The THD performance of single phase five level inverter using pr and harmonic compensators current controller
title_fullStr The THD performance of single phase five level inverter using pr and harmonic compensators current controller
title_full_unstemmed The THD performance of single phase five level inverter using pr and harmonic compensators current controller
title_sort thd performance of single phase five level inverter using pr and harmonic compensators current controller
publishDate 2020
url http://eprints.uthm.edu.my/377/1/24p%20ABDULLAHI%20MOHAMED%20ABDULLAHI.pdf
http://eprints.uthm.edu.my/377/2/ABDULLAHI%20MOHAMED%20ABDULLAHI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/377/3/ABDULLAHI%20MOHAMED%20ABDULLAHI%20WATERMARK.pdf
http://eprints.uthm.edu.my/377/
_version_ 1738580728779636736
score 13.244745