Classification of critical aging segments of power transmission lines

An Analytic Hierarchy Process (AHP) approach been used for analysis, comparison and classify the quality of several parameters that affect the conductor thermal ratings. The method is based on pairwise comparison between several factors that affect the alternatives in a hierarchical structure. Th...

Full description

Saved in:
Bibliographic Details
Main Author: Mohamed Ariffin, Nur Azliatun Hisan
Format: Thesis
Language:English
English
Published: 2011
Subjects:
Online Access:http://eprints.uthm.edu.my/2772/1/24p%20NUR%20AZLIATUN%20HISAN%20MOHAMED%20ARIFFIN.pdf
http://eprints.uthm.edu.my/2772/2/NUR%20AZLIATUN%20HISAN%20MOHAMED%20ARIFFIN%20WATERMARK.pdf
http://eprints.uthm.edu.my/2772/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.2772
record_format eprints
spelling my.uthm.eprints.27722021-11-01T07:06:55Z http://eprints.uthm.edu.my/2772/ Classification of critical aging segments of power transmission lines Mohamed Ariffin, Nur Azliatun Hisan TK Electrical engineering. Electronics Nuclear engineering TK3001-3521 Distribution or transmission of electric power An Analytic Hierarchy Process (AHP) approach been used for analysis, comparison and classify the quality of several parameters that affect the conductor thermal ratings. The method is based on pairwise comparison between several factors that affect the alternatives in a hierarchical structure. The thermal ratings of power transmission lines is basically based on the maximum permissible temperature of the conductors. Conductor can lose their tensile strength due to thermal load or annealing. This paper analysis thermal aging using known characteristics of transmission conductor, load information and weather data. By analyzing the conductor temperatures, aging due to loss of conductor tensile strength is estimated at individual locations along the transmission corridor. The proposed methodology is illustrated using a case study analyzing a power transmission line in Kluang, Johor. This information is important for transmission network operating procedures, scheduling of line inspections, maintenance, or reconductoring. 2011-04 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/2772/1/24p%20NUR%20AZLIATUN%20HISAN%20MOHAMED%20ARIFFIN.pdf text en http://eprints.uthm.edu.my/2772/2/NUR%20AZLIATUN%20HISAN%20MOHAMED%20ARIFFIN%20WATERMARK.pdf Mohamed Ariffin, Nur Azliatun Hisan (2011) Classification of critical aging segments of power transmission lines. Masters thesis, Universiti Tun Hussein Malaysia.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
English
topic TK Electrical engineering. Electronics Nuclear engineering
TK3001-3521 Distribution or transmission of electric power
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
TK3001-3521 Distribution or transmission of electric power
Mohamed Ariffin, Nur Azliatun Hisan
Classification of critical aging segments of power transmission lines
description An Analytic Hierarchy Process (AHP) approach been used for analysis, comparison and classify the quality of several parameters that affect the conductor thermal ratings. The method is based on pairwise comparison between several factors that affect the alternatives in a hierarchical structure. The thermal ratings of power transmission lines is basically based on the maximum permissible temperature of the conductors. Conductor can lose their tensile strength due to thermal load or annealing. This paper analysis thermal aging using known characteristics of transmission conductor, load information and weather data. By analyzing the conductor temperatures, aging due to loss of conductor tensile strength is estimated at individual locations along the transmission corridor. The proposed methodology is illustrated using a case study analyzing a power transmission line in Kluang, Johor. This information is important for transmission network operating procedures, scheduling of line inspections, maintenance, or reconductoring.
format Thesis
author Mohamed Ariffin, Nur Azliatun Hisan
author_facet Mohamed Ariffin, Nur Azliatun Hisan
author_sort Mohamed Ariffin, Nur Azliatun Hisan
title Classification of critical aging segments of power transmission lines
title_short Classification of critical aging segments of power transmission lines
title_full Classification of critical aging segments of power transmission lines
title_fullStr Classification of critical aging segments of power transmission lines
title_full_unstemmed Classification of critical aging segments of power transmission lines
title_sort classification of critical aging segments of power transmission lines
publishDate 2011
url http://eprints.uthm.edu.my/2772/1/24p%20NUR%20AZLIATUN%20HISAN%20MOHAMED%20ARIFFIN.pdf
http://eprints.uthm.edu.my/2772/2/NUR%20AZLIATUN%20HISAN%20MOHAMED%20ARIFFIN%20WATERMARK.pdf
http://eprints.uthm.edu.my/2772/
_version_ 1738581034716364800
score 13.211869