Ammonia detection in water using balloon-like fiber optic sensor coated with oxazine and PDMS
This paper presents the detection of ammonia in water using a balloon-like fiber optic sensor coated with Oxazine 170 perchlorate and polydimethylsiloxane (PDMS). The sensor was prepared by removing a middle portion of a plastic optical fiber cladding using acetone. The uncladded fiber optic sensor...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2024
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/12130/1/J17690_a2249f5f04e00d6da720f1b63bca34b6.pdf http://eprints.uthm.edu.my/12130/ https://doi.org/10.1016/j.ijleo.2024.171677 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uthm.eprints.12130 |
---|---|
record_format |
eprints |
spelling |
my.uthm.eprints.121302024-12-01T04:19:55Z http://eprints.uthm.edu.my/12130/ Ammonia detection in water using balloon-like fiber optic sensor coated with oxazine and PDMS Abd Rashid, Nurfatihah Che Cholan, Noran Azizan Tay, Kim Gaik Mat Daud, Azra Munirah Jaharudin, Nurul Atika Nabila Sulaiman, Nazrah Ilyana Ngajikin, Nor Hafizah QD Chemistry This paper presents the detection of ammonia in water using a balloon-like fiber optic sensor coated with Oxazine 170 perchlorate and polydimethylsiloxane (PDMS). The sensor was prepared by removing a middle portion of a plastic optical fiber cladding using acetone. The uncladded fiber optic sensor was then bent into a balloon-like shape using a 3D printed fiber holder to fix the diameter of the bent structure and a shrink tube to maintain the curvature of the balloon-like structure. A thin layer of Oxazine 170 perchlorate (sensing material) was then deposited on the fiber surface before it was dip coated with PDMS for the protection of the sensing material. Experimental results revealed that the sensor has linear relationship with ammonia concentration ranging from 0 mg/L to 15 mg/L. Moreover, the sensor managed to achieve the sensor sensitivity of 0.006 (mg/L)− 1 , linearity of 0.9154, resolution of 1.6667 mg/L, LOD of 2.9556 mg/L, average stability precision of 99.8 % and RSD of 0.0308 %. Elsevier 2024 Article PeerReviewed text en http://eprints.uthm.edu.my/12130/1/J17690_a2249f5f04e00d6da720f1b63bca34b6.pdf Abd Rashid, Nurfatihah Che and Cholan, Noran Azizan and Tay, Kim Gaik and Mat Daud, Azra Munirah and Jaharudin, Nurul Atika Nabila and Sulaiman, Nazrah Ilyana and Ngajikin, Nor Hafizah (2024) Ammonia detection in water using balloon-like fiber optic sensor coated with oxazine and PDMS. Optik, 301. pp. 1-11. https://doi.org/10.1016/j.ijleo.2024.171677 |
institution |
Universiti Tun Hussein Onn Malaysia |
building |
UTHM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tun Hussein Onn Malaysia |
content_source |
UTHM Institutional Repository |
url_provider |
http://eprints.uthm.edu.my/ |
language |
English |
topic |
QD Chemistry |
spellingShingle |
QD Chemistry Abd Rashid, Nurfatihah Che Cholan, Noran Azizan Tay, Kim Gaik Mat Daud, Azra Munirah Jaharudin, Nurul Atika Nabila Sulaiman, Nazrah Ilyana Ngajikin, Nor Hafizah Ammonia detection in water using balloon-like fiber optic sensor coated with oxazine and PDMS |
description |
This paper presents the detection of ammonia in water using a balloon-like fiber optic sensor coated with Oxazine 170 perchlorate and polydimethylsiloxane (PDMS). The sensor was prepared by removing a middle portion of a plastic optical fiber cladding using acetone. The uncladded
fiber optic sensor was then bent into a balloon-like shape using a 3D printed fiber holder to fix the diameter of the bent structure and a shrink tube to maintain the curvature of the balloon-like structure. A thin layer of Oxazine 170 perchlorate (sensing material) was then deposited on the fiber surface before it was dip coated with PDMS for the protection of the sensing material. Experimental results revealed that the sensor has linear relationship with ammonia concentration
ranging from 0 mg/L to 15 mg/L. Moreover, the sensor managed to achieve the sensor sensitivity of 0.006 (mg/L)− 1
, linearity of 0.9154, resolution of 1.6667 mg/L, LOD of 2.9556 mg/L, average stability precision of 99.8 % and RSD of 0.0308 %. |
format |
Article |
author |
Abd Rashid, Nurfatihah Che Cholan, Noran Azizan Tay, Kim Gaik Mat Daud, Azra Munirah Jaharudin, Nurul Atika Nabila Sulaiman, Nazrah Ilyana Ngajikin, Nor Hafizah |
author_facet |
Abd Rashid, Nurfatihah Che Cholan, Noran Azizan Tay, Kim Gaik Mat Daud, Azra Munirah Jaharudin, Nurul Atika Nabila Sulaiman, Nazrah Ilyana Ngajikin, Nor Hafizah |
author_sort |
Abd Rashid, Nurfatihah Che |
title |
Ammonia detection in water using balloon-like fiber optic sensor coated with oxazine and PDMS |
title_short |
Ammonia detection in water using balloon-like fiber optic sensor coated with oxazine and PDMS |
title_full |
Ammonia detection in water using balloon-like fiber optic sensor coated with oxazine and PDMS |
title_fullStr |
Ammonia detection in water using balloon-like fiber optic sensor coated with oxazine and PDMS |
title_full_unstemmed |
Ammonia detection in water using balloon-like fiber optic sensor coated with oxazine and PDMS |
title_sort |
ammonia detection in water using balloon-like fiber optic sensor coated with oxazine and pdms |
publisher |
Elsevier |
publishDate |
2024 |
url |
http://eprints.uthm.edu.my/12130/1/J17690_a2249f5f04e00d6da720f1b63bca34b6.pdf http://eprints.uthm.edu.my/12130/ https://doi.org/10.1016/j.ijleo.2024.171677 |
_version_ |
1817845169265836032 |
score |
13.223943 |