Impact of the rotor on FRA signatures and its implications for motor health assessment
Electrical machine condition monitoring is essential in industrial processes for increasing workplace security, ensuring reliability, and cost-effective machine operation. The frequency response analysis (FRA) monitoring technique is gaining heightened popularity due to its reliability. The main...
Saved in:
Main Authors: | Khan, R., Yousof, M. F. M., Abd-Rahman, R., Al-Ameri, S. M., Azis, N. |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2024
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/11262/1/P16748_4ef608c72a94a4cca31338c62b4eb03d%2011.pdf http://eprints.uthm.edu.my/11262/ http:\\10.1109/GECOST60902.2024.10474882 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
A New Approach for Estimating Insulation Condition of Field Transformers Using FRA
by: Yousof, Mohd Fairouz Mohd, et al.
Published: (2020) -
Improvement of distribution transformer fault analysis using FRA method
by: Nasser Al-Ameri, Salem Mgammal Awadh
Published: (2019) -
The Effect Of Short Circuit Fault On One Winding To Other Windings In FRA
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2019) -
Motor current signature analysis of incipient broken rotor bar of squirrel cage induction motor
by: Mehrjou, Mohammad Rezazadeh
Published: (2011) -
Evaluation of numerical techniques to analyze Frequency Response Analysis (FRA) measurements of power transformer
by: Eyam, Anan
Published: (2010)