Power Quality Signals Detection Using S-Transform
Power quality has become very important issue over the last decade. Poor quality can cause equipment failure, data and economical. An automated monitoring system is needed to ensure signal quality, reduces diagnostic time and rectifies failures. In this paper, S-transform is used to analyze the...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2013
|
Subjects: | |
Online Access: | http://eprints.utem.edu.my/id/eprint/9461/2/2013_Paper_Power_Quality_Signals_Detection_Using_S-Transform.pdf http://eprints.utem.edu.my/id/eprint/9461/ http://ieeexplore.ieee.org/xpl/articleDetails.jsp?tp=&arnumber=6564609&queryText%3DPower+Quality+Signals+Detection+Using+S-Transform |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utem.eprints.9461 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.94612015-05-28T04:04:12Z http://eprints.utem.edu.my/id/eprint/9461/ Power Quality Signals Detection Using S-Transform ahmad, Nur Hafizatul Tul Huda Abdullah, Abdul Rahim JOPRI, MOHD HATTA TK Electrical engineering. Electronics Nuclear engineering Power quality has become very important issue over the last decade. Poor quality can cause equipment failure, data and economical. An automated monitoring system is needed to ensure signal quality, reduces diagnostic time and rectifies failures. In this paper, S-transform is used to analyze the power quality signals such as swell, sag, interruption, harmonic, interharmonic and transient based on IEEE Std. 1159-2009 to detect, localize and classify the disturbance. The S-transform is used to represent the signals in time-frequency representation (TFR). ).To get an accurate TFR, the parameters are estimated to identify the signal characteristics. The signal characteristics are the root means square voltage (Vrms), total harmonic distortion (THD), total non harmonic distortion (TnHD) and total waveform distortion (TWD). To verify the performance of Stransform several sets of data with different time duration are analyzed to determine the accuracy of S-transform. The lowest value of mean absolute percentage error (MAPE) gives the highest accuracy to provide the best performance of TFD. 2013-06-03 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utem.edu.my/id/eprint/9461/2/2013_Paper_Power_Quality_Signals_Detection_Using_S-Transform.pdf ahmad, Nur Hafizatul Tul Huda and Abdullah, Abdul Rahim and JOPRI, MOHD HATTA (2013) Power Quality Signals Detection Using S-Transform. In: Power Engineering and Optimization Conference (PEOCO), 2013 IEEE 7th International, 3 june 2013, Langkawi Island, Malaysia. http://ieeexplore.ieee.org/xpl/articleDetails.jsp?tp=&arnumber=6564609&queryText%3DPower+Quality+Signals+Detection+Using+S-Transform |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering ahmad, Nur Hafizatul Tul Huda Abdullah, Abdul Rahim JOPRI, MOHD HATTA Power Quality Signals Detection Using S-Transform |
description |
Power quality has become very important issue over
the last decade. Poor quality can cause equipment failure, data
and economical. An automated monitoring system is needed to
ensure signal quality, reduces diagnostic time and rectifies
failures. In this paper, S-transform is used to analyze the power
quality signals such as swell, sag, interruption, harmonic,
interharmonic and transient based on IEEE Std. 1159-2009 to
detect, localize and classify the disturbance. The S-transform is
used to represent the signals in time-frequency representation
(TFR). ).To get an accurate TFR, the parameters are estimated to
identify the signal characteristics. The signal characteristics are
the root means square voltage (Vrms), total harmonic distortion (THD), total non harmonic distortion (TnHD) and total waveform distortion (TWD). To verify the performance of Stransform several sets of data with different time duration are analyzed to determine the accuracy of S-transform. The lowest value of mean absolute percentage error (MAPE) gives the highest accuracy to provide the best performance of TFD. |
format |
Conference or Workshop Item |
author |
ahmad, Nur Hafizatul Tul Huda Abdullah, Abdul Rahim JOPRI, MOHD HATTA |
author_facet |
ahmad, Nur Hafizatul Tul Huda Abdullah, Abdul Rahim JOPRI, MOHD HATTA |
author_sort |
ahmad, Nur Hafizatul Tul Huda |
title |
Power Quality Signals Detection Using S-Transform |
title_short |
Power Quality Signals Detection Using S-Transform |
title_full |
Power Quality Signals Detection Using S-Transform |
title_fullStr |
Power Quality Signals Detection Using S-Transform |
title_full_unstemmed |
Power Quality Signals Detection Using S-Transform |
title_sort |
power quality signals detection using s-transform |
publishDate |
2013 |
url |
http://eprints.utem.edu.my/id/eprint/9461/2/2013_Paper_Power_Quality_Signals_Detection_Using_S-Transform.pdf http://eprints.utem.edu.my/id/eprint/9461/ http://ieeexplore.ieee.org/xpl/articleDetails.jsp?tp=&arnumber=6564609&queryText%3DPower+Quality+Signals+Detection+Using+S-Transform |
_version_ |
1665905401689800704 |
score |
13.211869 |