A computational study of a passive flow device in a mechanical heart valve for the anatomic aorta and the axisymmetric aorta
Artificial heart valves for replacing diseased indigenous heart valves were widely used. The treatment of certain types of heart disease requires mechanical valves to be implanted operatively. Healthy cardiac valves are essential to proper cardiac function. The current study presents an investigatio...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit Akademia Baru
2021
|
Online Access: | http://eprints.utem.edu.my/id/eprint/25854/2/2517-MANUSCRIPT%20WITH%20AUTHORS%20DETAILS-17620-1-10-20210502%20%281%29.PDF http://eprints.utem.edu.my/id/eprint/25854/ https://www.akademiabaru.com/submit/index.php/cfdl/article/view/2517/2831 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utem.eprints.25854 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.258542022-04-13T16:15:09Z http://eprints.utem.edu.my/id/eprint/25854/ A computational study of a passive flow device in a mechanical heart valve for the anatomic aorta and the axisymmetric aorta Zakaria, Mohamad Shukri Abd. Latif, Mohd Juzaila Mohd Salleh, Nursyaira Basri, Adi Azriff Artificial heart valves for replacing diseased indigenous heart valves were widely used. The treatment of certain types of heart disease requires mechanical valves to be implanted operatively. Healthy cardiac valves are essential to proper cardiac function. The current study presents an investigation of the pulsatile blood flow through a bileaflet mechanical heart valve (BMHV) with a vortex generator (VG) in fully open position. A St. Jude Medical Regent valve with a diameter of 23 mm was used to mount triangular VGs as a means of improving pressure gradients and reducing turbulence. The anatomic aorta and axisymmetric aorta was computed by large eddy simulation (LES) approached. The implications for both models with VGs were observed in terms of velocity magnitude, vortices and wall shear stress. The results suggested that the anatomic aorta is prone to develop more blood clotting at the leading edge of the leaflets with 2.03 m/s. Furthermore, the anatomic aorta produces higher wall shear stress with 69Pa, which possibly contributes to a high risk of thrombosis. Penerbit Akademia Baru 2021-04 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/25854/2/2517-MANUSCRIPT%20WITH%20AUTHORS%20DETAILS-17620-1-10-20210502%20%281%29.PDF Zakaria, Mohamad Shukri and Abd. Latif, Mohd Juzaila and Mohd Salleh, Nursyaira and Basri, Adi Azriff (2021) A computational study of a passive flow device in a mechanical heart valve for the anatomic aorta and the axisymmetric aorta. CFD Letters, 13 (4). pp. 69-79. ISSN 2180-1363 https://www.akademiabaru.com/submit/index.php/cfdl/article/view/2517/2831 10.37934/cfdl.13.4.6979 |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
description |
Artificial heart valves for replacing diseased indigenous heart valves were widely used. The treatment of certain types of heart disease requires mechanical valves to be implanted operatively. Healthy cardiac valves are essential to proper cardiac function. The current study presents an investigation of the pulsatile blood flow through a bileaflet mechanical heart valve (BMHV) with a vortex generator (VG) in fully open position. A St. Jude Medical Regent valve with a diameter of 23 mm was used to mount triangular VGs as a means of improving pressure gradients and reducing turbulence. The anatomic aorta and axisymmetric aorta was computed by large eddy simulation (LES) approached. The implications for both models with VGs were observed in terms of velocity magnitude, vortices and wall shear stress. The results suggested that the anatomic aorta is prone to develop more blood clotting at the leading edge of the leaflets with 2.03 m/s. Furthermore, the anatomic aorta produces higher wall shear stress with 69Pa, which possibly contributes to a high risk of thrombosis. |
format |
Article |
author |
Zakaria, Mohamad Shukri Abd. Latif, Mohd Juzaila Mohd Salleh, Nursyaira Basri, Adi Azriff |
spellingShingle |
Zakaria, Mohamad Shukri Abd. Latif, Mohd Juzaila Mohd Salleh, Nursyaira Basri, Adi Azriff A computational study of a passive flow device in a mechanical heart valve for the anatomic aorta and the axisymmetric aorta |
author_facet |
Zakaria, Mohamad Shukri Abd. Latif, Mohd Juzaila Mohd Salleh, Nursyaira Basri, Adi Azriff |
author_sort |
Zakaria, Mohamad Shukri |
title |
A computational study of a passive flow device in a mechanical heart valve for the anatomic aorta and the axisymmetric aorta |
title_short |
A computational study of a passive flow device in a mechanical heart valve for the anatomic aorta and the axisymmetric aorta |
title_full |
A computational study of a passive flow device in a mechanical heart valve for the anatomic aorta and the axisymmetric aorta |
title_fullStr |
A computational study of a passive flow device in a mechanical heart valve for the anatomic aorta and the axisymmetric aorta |
title_full_unstemmed |
A computational study of a passive flow device in a mechanical heart valve for the anatomic aorta and the axisymmetric aorta |
title_sort |
computational study of a passive flow device in a mechanical heart valve for the anatomic aorta and the axisymmetric aorta |
publisher |
Penerbit Akademia Baru |
publishDate |
2021 |
url |
http://eprints.utem.edu.my/id/eprint/25854/2/2517-MANUSCRIPT%20WITH%20AUTHORS%20DETAILS-17620-1-10-20210502%20%281%29.PDF http://eprints.utem.edu.my/id/eprint/25854/ https://www.akademiabaru.com/submit/index.php/cfdl/article/view/2517/2831 |
_version_ |
1731229670772310016 |
score |
13.211869 |