Performance Of Thermal Electric Cooling (TEC) Air Condition For A Small Office Space

An experimental investigation on the TEC (thermoelectric cooler) air-conditioner with evaporative cooler that acts as condensing unit in a small of ice space was performed. Various engineering performance criteria of the system such as the Coef icient of Performance (COP) of the TEC plate, the COP o...

Full description

Saved in:
Bibliographic Details
Main Authors: Shamsudin, Shamsul Anuar, Abd Aziz, Muhammad Syahril, Sudin, Mohd Nizam, Ismail, Mohd. Farid, Huthaifa Ahmad Al-Issa
Format: Article
Language:English
Published: Penerbit UniMAP 2021
Online Access:http://eprints.utem.edu.my/id/eprint/25774/3/Vol%2014%20SI%20Aug2021%20395-412.pdf
http://eprints.utem.edu.my/id/eprint/25774/
https://ijneam.unimap.edu.my/images/PDF/IJNeaM%20Special%20Issue%202021%20(1)/Vol%2014%20SI%20Aug2021%20395-412.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.25774
record_format eprints
spelling my.utem.eprints.257742022-03-17T11:10:01Z http://eprints.utem.edu.my/id/eprint/25774/ Performance Of Thermal Electric Cooling (TEC) Air Condition For A Small Office Space Shamsudin, Shamsul Anuar Abd Aziz, Muhammad Syahril Sudin, Mohd Nizam Ismail, Mohd. Farid Huthaifa Ahmad Al-Issa An experimental investigation on the TEC (thermoelectric cooler) air-conditioner with evaporative cooler that acts as condensing unit in a small of ice space was performed. Various engineering performance criteria of the system such as the Coef icient of Performance (COP) of the TEC plate, the COP of the developed product, the COP of evaporative cooler and the sound level of the product were evaluated. The tested area of ice size was 12 ft × 11 ft, used for light activities and with few equipment generating heat. As a result, the TEC air conditioner by evaporative cooling was developed that consists of several parts that include thermoelectric modules model TEC-12706, heatsinkfan, water heatsink, water pump, water pipeline, radiator, and evaporative cooler. This experiment found that the COP of the TEC plates condensed by evaporative cooling is 0.39. The optimum running current for the system is 5 A when the system’s COP achieved the highest values which is 1.7. The COP of the evaporative cooling decreases with the increment of the current supply to the TEC. Consequently, the 62.9 dB sound level of the system is acceptable. Penerbit UniMAP 2021-08 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/25774/3/Vol%2014%20SI%20Aug2021%20395-412.pdf Shamsudin, Shamsul Anuar and Abd Aziz, Muhammad Syahril and Sudin, Mohd Nizam and Ismail, Mohd. Farid and Huthaifa Ahmad Al-Issa (2021) Performance Of Thermal Electric Cooling (TEC) Air Condition For A Small Office Space. International Journal of Nanoelectronics and Materials, 14 (SI). pp. 395-412. ISSN 1985-5761 https://ijneam.unimap.edu.my/images/PDF/IJNeaM%20Special%20Issue%202021%20(1)/Vol%2014%20SI%20Aug2021%20395-412.pdf
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
description An experimental investigation on the TEC (thermoelectric cooler) air-conditioner with evaporative cooler that acts as condensing unit in a small of ice space was performed. Various engineering performance criteria of the system such as the Coef icient of Performance (COP) of the TEC plate, the COP of the developed product, the COP of evaporative cooler and the sound level of the product were evaluated. The tested area of ice size was 12 ft × 11 ft, used for light activities and with few equipment generating heat. As a result, the TEC air conditioner by evaporative cooling was developed that consists of several parts that include thermoelectric modules model TEC-12706, heatsinkfan, water heatsink, water pump, water pipeline, radiator, and evaporative cooler. This experiment found that the COP of the TEC plates condensed by evaporative cooling is 0.39. The optimum running current for the system is 5 A when the system’s COP achieved the highest values which is 1.7. The COP of the evaporative cooling decreases with the increment of the current supply to the TEC. Consequently, the 62.9 dB sound level of the system is acceptable.
format Article
author Shamsudin, Shamsul Anuar
Abd Aziz, Muhammad Syahril
Sudin, Mohd Nizam
Ismail, Mohd. Farid
Huthaifa Ahmad Al-Issa
spellingShingle Shamsudin, Shamsul Anuar
Abd Aziz, Muhammad Syahril
Sudin, Mohd Nizam
Ismail, Mohd. Farid
Huthaifa Ahmad Al-Issa
Performance Of Thermal Electric Cooling (TEC) Air Condition For A Small Office Space
author_facet Shamsudin, Shamsul Anuar
Abd Aziz, Muhammad Syahril
Sudin, Mohd Nizam
Ismail, Mohd. Farid
Huthaifa Ahmad Al-Issa
author_sort Shamsudin, Shamsul Anuar
title Performance Of Thermal Electric Cooling (TEC) Air Condition For A Small Office Space
title_short Performance Of Thermal Electric Cooling (TEC) Air Condition For A Small Office Space
title_full Performance Of Thermal Electric Cooling (TEC) Air Condition For A Small Office Space
title_fullStr Performance Of Thermal Electric Cooling (TEC) Air Condition For A Small Office Space
title_full_unstemmed Performance Of Thermal Electric Cooling (TEC) Air Condition For A Small Office Space
title_sort performance of thermal electric cooling (tec) air condition for a small office space
publisher Penerbit UniMAP
publishDate 2021
url http://eprints.utem.edu.my/id/eprint/25774/3/Vol%2014%20SI%20Aug2021%20395-412.pdf
http://eprints.utem.edu.my/id/eprint/25774/
https://ijneam.unimap.edu.my/images/PDF/IJNeaM%20Special%20Issue%202021%20(1)/Vol%2014%20SI%20Aug2021%20395-412.pdf
_version_ 1728055215982116864
score 13.211869