Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect
This study reviews the recent advances of thermoelectric materials, modelling approaches, and applications. Thermoelectric cooling systems have advantages over conventional cooling devices, including compact in size, light in weight, high reliability, no mechanical moving parts, no working fluid, be...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit Akademia Baru
2019
|
Online Access: | http://eprints.utem.edu.my/id/eprint/24316/2/2019_PERFORMANCE%20ANALYSIS%20OF%20LIQUID-COOLED%20PANEL%20SYSTEM%20FOR%20AIR%20CONDITIONER%20USING%20PELTIER%20EFFECT.PDF http://eprints.utem.edu.my/id/eprint/24316/ http://www.akademiabaru.com/doc/ARFMTSV62_N1_P31_42.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utem.eprints.24316 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.243162020-10-21T14:08:03Z http://eprints.utem.edu.my/id/eprint/24316/ Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect Harun, Mohamad Haniff Mohd Ab. Halim, Mohd Firdaus Azahar, Arman Hadi Yaakub, Muhamad Faizal Md Basar, Mohd Farriz Zainal Abidin, Amar Faiz Mohd Aras, Mohd Shahrieel This study reviews the recent advances of thermoelectric materials, modelling approaches, and applications. Thermoelectric cooling systems have advantages over conventional cooling devices, including compact in size, light in weight, high reliability, no mechanical moving parts, no working fluid, being powered by direct current, and easily switching between cooling and heating modes. In this study, it focused on the replacement of the outdoor unit (compressor) for conventional air-conditioner. This system using water as cooling agent in replacing refrigerant system. It involves using Peltier Effect which converts current to rise the temperature between the two junctions of the Peltier. The water will flow through these changes in temperature which results in cooling the air through the process. From this process, it taken 60 minutes in order to achieve 20.2 °C and consumed 1.3 A which is better rather using the conventional method. This can reduce the cost of the project in terms of maintenance, bills, materials and gases. This system can be operated without relying to the compressor which improve the systems in terms of noise, low electricity usage, small size and use water as coolant agent. Penerbit Akademia Baru 2019-10 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/24316/2/2019_PERFORMANCE%20ANALYSIS%20OF%20LIQUID-COOLED%20PANEL%20SYSTEM%20FOR%20AIR%20CONDITIONER%20USING%20PELTIER%20EFFECT.PDF Harun, Mohamad Haniff and Mohd Ab. Halim, Mohd Firdaus and Azahar, Arman Hadi and Yaakub, Muhamad Faizal and Md Basar, Mohd Farriz and Zainal Abidin, Amar Faiz and Mohd Aras, Mohd Shahrieel (2019) Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 62 (1). pp. 31-42. ISSN 2289-7879 http://www.akademiabaru.com/doc/ARFMTSV62_N1_P31_42.pdf |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
description |
This study reviews the recent advances of thermoelectric materials, modelling approaches, and applications. Thermoelectric cooling systems have advantages over conventional cooling devices, including compact in size, light in weight, high reliability, no mechanical moving parts, no working fluid, being powered by direct current, and easily switching between cooling and heating modes. In this study, it focused on the replacement of the outdoor unit (compressor) for conventional air-conditioner. This system using water as cooling agent in replacing refrigerant system. It involves using Peltier Effect which converts current to rise the temperature between the two junctions of the Peltier. The water will flow through these changes in temperature which results in cooling the air through the process. From this process, it taken 60 minutes in order to achieve 20.2 °C and consumed 1.3 A which is better rather using the conventional method. This can reduce the cost of the project in terms of maintenance, bills, materials and gases. This system can be operated without relying to the compressor which improve the systems in terms of noise, low electricity usage, small size and use water as coolant agent. |
format |
Article |
author |
Harun, Mohamad Haniff Mohd Ab. Halim, Mohd Firdaus Azahar, Arman Hadi Yaakub, Muhamad Faizal Md Basar, Mohd Farriz Zainal Abidin, Amar Faiz Mohd Aras, Mohd Shahrieel |
spellingShingle |
Harun, Mohamad Haniff Mohd Ab. Halim, Mohd Firdaus Azahar, Arman Hadi Yaakub, Muhamad Faizal Md Basar, Mohd Farriz Zainal Abidin, Amar Faiz Mohd Aras, Mohd Shahrieel Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect |
author_facet |
Harun, Mohamad Haniff Mohd Ab. Halim, Mohd Firdaus Azahar, Arman Hadi Yaakub, Muhamad Faizal Md Basar, Mohd Farriz Zainal Abidin, Amar Faiz Mohd Aras, Mohd Shahrieel |
author_sort |
Harun, Mohamad Haniff |
title |
Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect |
title_short |
Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect |
title_full |
Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect |
title_fullStr |
Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect |
title_full_unstemmed |
Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect |
title_sort |
performance analysis of liquid-cooled panel system for air conditioner using peltier effect |
publisher |
Penerbit Akademia Baru |
publishDate |
2019 |
url |
http://eprints.utem.edu.my/id/eprint/24316/2/2019_PERFORMANCE%20ANALYSIS%20OF%20LIQUID-COOLED%20PANEL%20SYSTEM%20FOR%20AIR%20CONDITIONER%20USING%20PELTIER%20EFFECT.PDF http://eprints.utem.edu.my/id/eprint/24316/ http://www.akademiabaru.com/doc/ARFMTSV62_N1_P31_42.pdf |
_version_ |
1681492547745087488 |
score |
13.211869 |