Independent Control For Dual-PMSM Drives Using Five-Leg Inverter

This paper aims to implement an independent speed control for dual-PMSM drives fed by a single Five-Leg Inverter (FLI). In general, dual-motor drives are designed to reduce size and cost with respect to single motor drives. However, dual-motor drives using a single three-leg inverter has its limitat...

Full description

Saved in:
Bibliographic Details
Main Authors: Jurifa, Mat Lazi, Zulkifilie, Ibrahim, Marizan, Sulaiman, Azziddin, Mohamad Razali, Norazelina, Kamisman
Format: Article
Language:English
Published: Institute Of Electrical And Electronics Engineers Inc. (IEEE) 2016
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/17210/1/Independent%20Control%20For%20Dual-PMSM%20Drives%20Using%20Five-Leg%20Inverter.pdf
http://eprints.utem.edu.my/id/eprint/17210/
http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7409529
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.17210
record_format eprints
spelling my.utem.eprints.172102021-09-11T18:52:02Z http://eprints.utem.edu.my/id/eprint/17210/ Independent Control For Dual-PMSM Drives Using Five-Leg Inverter Jurifa, Mat Lazi Zulkifilie, Ibrahim Marizan, Sulaiman Azziddin, Mohamad Razali Norazelina, Kamisman T Technology (General) This paper aims to implement an independent speed control for dual-PMSM drives fed by a single Five-Leg Inverter (FLI). In general, dual-motor drives are designed to reduce size and cost with respect to single motor drives. However, dual-motor drives using a single three-leg inverter has its limitation in the case of operation at different operating conditions and independent speed control requirement. By employing this FLI topology, the dual-motor drives can be used for four-quadrant control, variable speed operation and load disturbance rejection. In other words, it can be operated for different applications. This paper investigates the behaviour of independent speed control for Dual-Permanent Magnet Synchronous Motor drives. The speed and current controllers are implemented in d-q rotor reference frame using Simulink/MATLAB and the switching signals are generated by the built-in function and dSPACE. The overall performance of the drives is presented in terms of speed responses under forward and reverse operation. The three-phase current and quadrature current responses are also included. The experimental results of the drives under investigated study have proven that dual-PMSM can independently controlled by using FLI. Institute Of Electrical And Electronics Engineers Inc. (IEEE) 2016 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/17210/1/Independent%20Control%20For%20Dual-PMSM%20Drives%20Using%20Five-Leg%20Inverter.pdf Jurifa, Mat Lazi and Zulkifilie, Ibrahim and Marizan, Sulaiman and Azziddin, Mohamad Razali and Norazelina, Kamisman (2016) Independent Control For Dual-PMSM Drives Using Five-Leg Inverter. 2015 IEEE Conference On Energy Conversion, CENCON 2015. pp. 143-148. ISSN 978-147998598-2 http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7409529 10.1109/CENCON.2015.7409529
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Jurifa, Mat Lazi
Zulkifilie, Ibrahim
Marizan, Sulaiman
Azziddin, Mohamad Razali
Norazelina, Kamisman
Independent Control For Dual-PMSM Drives Using Five-Leg Inverter
description This paper aims to implement an independent speed control for dual-PMSM drives fed by a single Five-Leg Inverter (FLI). In general, dual-motor drives are designed to reduce size and cost with respect to single motor drives. However, dual-motor drives using a single three-leg inverter has its limitation in the case of operation at different operating conditions and independent speed control requirement. By employing this FLI topology, the dual-motor drives can be used for four-quadrant control, variable speed operation and load disturbance rejection. In other words, it can be operated for different applications. This paper investigates the behaviour of independent speed control for Dual-Permanent Magnet Synchronous Motor drives. The speed and current controllers are implemented in d-q rotor reference frame using Simulink/MATLAB and the switching signals are generated by the built-in function and dSPACE. The overall performance of the drives is presented in terms of speed responses under forward and reverse operation. The three-phase current and quadrature current responses are also included. The experimental results of the drives under investigated study have proven that dual-PMSM can independently controlled by using FLI.
format Article
author Jurifa, Mat Lazi
Zulkifilie, Ibrahim
Marizan, Sulaiman
Azziddin, Mohamad Razali
Norazelina, Kamisman
author_facet Jurifa, Mat Lazi
Zulkifilie, Ibrahim
Marizan, Sulaiman
Azziddin, Mohamad Razali
Norazelina, Kamisman
author_sort Jurifa, Mat Lazi
title Independent Control For Dual-PMSM Drives Using Five-Leg Inverter
title_short Independent Control For Dual-PMSM Drives Using Five-Leg Inverter
title_full Independent Control For Dual-PMSM Drives Using Five-Leg Inverter
title_fullStr Independent Control For Dual-PMSM Drives Using Five-Leg Inverter
title_full_unstemmed Independent Control For Dual-PMSM Drives Using Five-Leg Inverter
title_sort independent control for dual-pmsm drives using five-leg inverter
publisher Institute Of Electrical And Electronics Engineers Inc. (IEEE)
publishDate 2016
url http://eprints.utem.edu.my/id/eprint/17210/1/Independent%20Control%20For%20Dual-PMSM%20Drives%20Using%20Five-Leg%20Inverter.pdf
http://eprints.utem.edu.my/id/eprint/17210/
http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7409529
_version_ 1712288907509366784
score 13.211869