Independent Control For Dual-PMSM Drives Using Five-Leg Inverter
This paper aims to implement an independent speed control for dual-PMSM drives fed by a single Five-Leg Inverter (FLI). In general, dual-motor drives are designed to reduce size and cost with respect to single motor drives. However, dual-motor drives using a single three-leg inverter has its limitat...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute Of Electrical And Electronics Engineers Inc. (IEEE)
2016
|
Subjects: | |
Online Access: | http://eprints.utem.edu.my/id/eprint/17210/1/Independent%20Control%20For%20Dual-PMSM%20Drives%20Using%20Five-Leg%20Inverter.pdf http://eprints.utem.edu.my/id/eprint/17210/ http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7409529 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utem.eprints.17210 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.172102021-09-11T18:52:02Z http://eprints.utem.edu.my/id/eprint/17210/ Independent Control For Dual-PMSM Drives Using Five-Leg Inverter Jurifa, Mat Lazi Zulkifilie, Ibrahim Marizan, Sulaiman Azziddin, Mohamad Razali Norazelina, Kamisman T Technology (General) This paper aims to implement an independent speed control for dual-PMSM drives fed by a single Five-Leg Inverter (FLI). In general, dual-motor drives are designed to reduce size and cost with respect to single motor drives. However, dual-motor drives using a single three-leg inverter has its limitation in the case of operation at different operating conditions and independent speed control requirement. By employing this FLI topology, the dual-motor drives can be used for four-quadrant control, variable speed operation and load disturbance rejection. In other words, it can be operated for different applications. This paper investigates the behaviour of independent speed control for Dual-Permanent Magnet Synchronous Motor drives. The speed and current controllers are implemented in d-q rotor reference frame using Simulink/MATLAB and the switching signals are generated by the built-in function and dSPACE. The overall performance of the drives is presented in terms of speed responses under forward and reverse operation. The three-phase current and quadrature current responses are also included. The experimental results of the drives under investigated study have proven that dual-PMSM can independently controlled by using FLI. Institute Of Electrical And Electronics Engineers Inc. (IEEE) 2016 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/17210/1/Independent%20Control%20For%20Dual-PMSM%20Drives%20Using%20Five-Leg%20Inverter.pdf Jurifa, Mat Lazi and Zulkifilie, Ibrahim and Marizan, Sulaiman and Azziddin, Mohamad Razali and Norazelina, Kamisman (2016) Independent Control For Dual-PMSM Drives Using Five-Leg Inverter. 2015 IEEE Conference On Energy Conversion, CENCON 2015. pp. 143-148. ISSN 978-147998598-2 http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7409529 10.1109/CENCON.2015.7409529 |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
topic |
T Technology (General) |
spellingShingle |
T Technology (General) Jurifa, Mat Lazi Zulkifilie, Ibrahim Marizan, Sulaiman Azziddin, Mohamad Razali Norazelina, Kamisman Independent Control For Dual-PMSM Drives Using Five-Leg Inverter |
description |
This paper aims to implement an independent speed control for dual-PMSM drives fed by a single Five-Leg Inverter (FLI). In general, dual-motor drives are designed to reduce size and cost with respect to single motor drives. However, dual-motor drives using a single three-leg inverter has its limitation in the case of operation at different operating conditions and independent speed control requirement. By employing this FLI topology, the dual-motor drives can be used for four-quadrant control, variable speed operation and load disturbance rejection. In other words, it can be operated for different applications. This paper investigates the behaviour of independent speed control for
Dual-Permanent Magnet Synchronous Motor drives. The speed
and current controllers are implemented in d-q rotor reference frame using Simulink/MATLAB and the switching signals are generated by the built-in function and dSPACE. The overall performance of the drives is presented in terms of speed responses under forward and reverse operation. The three-phase current and quadrature current responses are also included. The experimental results of the drives under investigated study have proven that dual-PMSM can independently controlled by using FLI. |
format |
Article |
author |
Jurifa, Mat Lazi Zulkifilie, Ibrahim Marizan, Sulaiman Azziddin, Mohamad Razali Norazelina, Kamisman |
author_facet |
Jurifa, Mat Lazi Zulkifilie, Ibrahim Marizan, Sulaiman Azziddin, Mohamad Razali Norazelina, Kamisman |
author_sort |
Jurifa, Mat Lazi |
title |
Independent Control For Dual-PMSM Drives Using Five-Leg Inverter |
title_short |
Independent Control For Dual-PMSM Drives Using Five-Leg Inverter |
title_full |
Independent Control For Dual-PMSM Drives Using Five-Leg Inverter |
title_fullStr |
Independent Control For Dual-PMSM Drives Using Five-Leg Inverter |
title_full_unstemmed |
Independent Control For Dual-PMSM Drives Using Five-Leg Inverter |
title_sort |
independent control for dual-pmsm drives using five-leg inverter |
publisher |
Institute Of Electrical And Electronics Engineers Inc. (IEEE) |
publishDate |
2016 |
url |
http://eprints.utem.edu.my/id/eprint/17210/1/Independent%20Control%20For%20Dual-PMSM%20Drives%20Using%20Five-Leg%20Inverter.pdf http://eprints.utem.edu.my/id/eprint/17210/ http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7409529 |
_version_ |
1712288907509366784 |
score |
13.211869 |