Open switch faults analysis in voltage source inverter using spectrogram

The performance and effects is critical factor in industry, especially usage power inverter such as motor, switching and control circuit. Until now, the statistic of effects still increase in the application. In order to overcome this, the spectrogram technique is used to represent the signals in ti...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdullah, Abdul Rahim, ahmad, nur sumayyah, Shair, Ezreen Farina, Jidin , Auzani
Format: Conference or Workshop Item
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/11436/1/2013_PEOCO_Open_switch_faults_analysis_in_voltage_source_inverter_using_spectrogram.pdf
http://eprints.utem.edu.my/id/eprint/11436/
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6564588&tag=1
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.11436
record_format eprints
spelling my.utem.eprints.114362015-05-28T04:17:20Z http://eprints.utem.edu.my/id/eprint/11436/ Open switch faults analysis in voltage source inverter using spectrogram Abdullah, Abdul Rahim ahmad, nur sumayyah Shair, Ezreen Farina Jidin , Auzani TK Electrical engineering. Electronics Nuclear engineering The performance and effects is critical factor in industry, especially usage power inverter such as motor, switching and control circuit. Until now, the statistic of effects still increase in the application. In order to overcome this, the spectrogram technique is used to represent the signals in time frequency representation (TFR). This paper introduces time-frequency distribution (TFD) technique for detecting and identifying the open circuit fault in application of inverter. The condition monitoring is based on time-frequency distribution. Since Fast Fourier Transform (FFT) is one of the techniques to analyze the signal, but it has some limitations in non-stationary signal. From TFR the parameters such as root means square voltage (Vrms), total waveform distortion (TWD), total harmonic distortion (THD) and total non-harmonics (TnHD) for voltage source inverter (VSI) are used to identify the characteristic of the signals. The result shows that spectrogram technique capable to identify and evaluate the information of voltage source inverter (VSI). The proposed technique is verified as simulation results. 2013-06-03 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utem.edu.my/id/eprint/11436/1/2013_PEOCO_Open_switch_faults_analysis_in_voltage_source_inverter_using_spectrogram.pdf Abdullah, Abdul Rahim and ahmad, nur sumayyah and Shair, Ezreen Farina and Jidin , Auzani (2013) Open switch faults analysis in voltage source inverter using spectrogram. In: Power Engineering and Optimization Conference (PEOCO), 2013 IEEE 7th International, 3-4 June 2013, Langkawi, Malaysia. http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6564588&tag=1
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Abdullah, Abdul Rahim
ahmad, nur sumayyah
Shair, Ezreen Farina
Jidin , Auzani
Open switch faults analysis in voltage source inverter using spectrogram
description The performance and effects is critical factor in industry, especially usage power inverter such as motor, switching and control circuit. Until now, the statistic of effects still increase in the application. In order to overcome this, the spectrogram technique is used to represent the signals in time frequency representation (TFR). This paper introduces time-frequency distribution (TFD) technique for detecting and identifying the open circuit fault in application of inverter. The condition monitoring is based on time-frequency distribution. Since Fast Fourier Transform (FFT) is one of the techniques to analyze the signal, but it has some limitations in non-stationary signal. From TFR the parameters such as root means square voltage (Vrms), total waveform distortion (TWD), total harmonic distortion (THD) and total non-harmonics (TnHD) for voltage source inverter (VSI) are used to identify the characteristic of the signals. The result shows that spectrogram technique capable to identify and evaluate the information of voltage source inverter (VSI). The proposed technique is verified as simulation results.
format Conference or Workshop Item
author Abdullah, Abdul Rahim
ahmad, nur sumayyah
Shair, Ezreen Farina
Jidin , Auzani
author_facet Abdullah, Abdul Rahim
ahmad, nur sumayyah
Shair, Ezreen Farina
Jidin , Auzani
author_sort Abdullah, Abdul Rahim
title Open switch faults analysis in voltage source inverter using spectrogram
title_short Open switch faults analysis in voltage source inverter using spectrogram
title_full Open switch faults analysis in voltage source inverter using spectrogram
title_fullStr Open switch faults analysis in voltage source inverter using spectrogram
title_full_unstemmed Open switch faults analysis in voltage source inverter using spectrogram
title_sort open switch faults analysis in voltage source inverter using spectrogram
publishDate 2013
url http://eprints.utem.edu.my/id/eprint/11436/1/2013_PEOCO_Open_switch_faults_analysis_in_voltage_source_inverter_using_spectrogram.pdf
http://eprints.utem.edu.my/id/eprint/11436/
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6564588&tag=1
_version_ 1665905461966143488
score 13.211869