Comparison of contrast enhancement and image quality using different contrast administration protocols for routine abdominal Computed Tomography (CT) in two centers
Background: Computed tomography (CT) scanning is a diagnostic imaging procedure that uses x-rays to build images of the body. CT scanning is an extremely common imaging modality in modern medicine. Contrast enhancement is the key component in CT scanning which helps to distinguish abnormal from n...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2021
|
Subjects: | |
Online Access: | http://eprints.usm.my/60619/1/Poh%20Choon%20Sian-E.pdf http://eprints.usm.my/60619/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.usm.eprints.60619 |
---|---|
record_format |
eprints |
spelling |
my.usm.eprints.60619 http://eprints.usm.my/60619/ Comparison of contrast enhancement and image quality using different contrast administration protocols for routine abdominal Computed Tomography (CT) in two centers Sian, Poh Choon R Medicine RA440-440.87 Study and teaching. Research Background: Computed tomography (CT) scanning is a diagnostic imaging procedure that uses x-rays to build images of the body. CT scanning is an extremely common imaging modality in modern medicine. Contrast enhancement is the key component in CT scanning which helps to distinguish abnormal from normal body structure. Numerous interacting factors can affect the quality of CECT images, which may be divided into three categories: patient, contrast medium and CT scanning. A lack of standardization has resulted in heterogeneous dosing regimens across radiology practices. The purpose of this study is to compare the effect of the two different scanning protocols mentioned above on the contrast enhancement and image quality of CECT abdomen. Methods: A cross-sectional study was conducted in Hospital Universiti Sains Malaysia (HUSM), Kota Bharu, Kelantan, Malaysia and Advanced Medical and Dental Institute (AMDI), Kepala Batas, Penang, Malaysia on 336 patients aged 18 and above with contrast-enhanced CT (CECT) scan of abdomen between January 2017 and December 2019. Images of the CECT abdomen using different protocol were collected retrospectively from these two centres: 168 patients from HUSM, using fixed contrast volume with fixed time-delay technique, and 168 patients from AMDI using weight-based contrast volume with automatic bolus tracking technique. Quantitative assessment was performed by measuring the degree of enhancement in region of interest and were quantified in Hounsfield unit (HU). Mean enhancement values from each protocol was assessed and compared using independent t-test. Qualitative assessment was performed in which the images will be graded by radiologist using 4 2021 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/60619/1/Poh%20Choon%20Sian-E.pdf Sian, Poh Choon (2021) Comparison of contrast enhancement and image quality using different contrast administration protocols for routine abdominal Computed Tomography (CT) in two centers. Masters thesis, Universiti Sains Malaysia. |
institution |
Universiti Sains Malaysia |
building |
Hamzah Sendut Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Sains Malaysia |
content_source |
USM Institutional Repository |
url_provider |
http://eprints.usm.my/ |
language |
English |
topic |
R Medicine RA440-440.87 Study and teaching. Research |
spellingShingle |
R Medicine RA440-440.87 Study and teaching. Research Sian, Poh Choon Comparison of contrast enhancement and image quality using different contrast administration protocols for routine abdominal Computed Tomography (CT) in two centers |
description |
Background: Computed tomography (CT) scanning is a diagnostic imaging
procedure that uses x-rays to build images of the body. CT scanning is an extremely
common imaging modality in modern medicine. Contrast enhancement is the key
component in CT scanning which helps to distinguish abnormal from normal body
structure. Numerous interacting factors can affect the quality of CECT images, which
may be divided into three categories: patient, contrast medium and CT scanning. A
lack of standardization has resulted in heterogeneous dosing regimens across
radiology practices. The purpose of this study is to compare the effect of the two
different scanning protocols mentioned above on the contrast enhancement and image
quality of CECT abdomen.
Methods: A cross-sectional study was conducted in Hospital Universiti Sains
Malaysia (HUSM), Kota Bharu, Kelantan, Malaysia and Advanced Medical and
Dental Institute (AMDI), Kepala Batas, Penang, Malaysia on 336 patients aged 18 and
above with contrast-enhanced CT (CECT) scan of abdomen between January 2017
and December 2019. Images of the CECT abdomen using different protocol were
collected retrospectively from these two centres: 168 patients from HUSM, using fixed
contrast volume with fixed time-delay technique, and 168 patients from AMDI using
weight-based contrast volume with automatic bolus tracking technique. Quantitative
assessment was performed by measuring the degree of enhancement in region of
interest and were quantified in Hounsfield unit (HU). Mean enhancement values from
each protocol was assessed and compared using independent t-test. Qualitative
assessment was performed in which the images will be graded by radiologist using 4 |
format |
Thesis |
author |
Sian, Poh Choon |
author_facet |
Sian, Poh Choon |
author_sort |
Sian, Poh Choon |
title |
Comparison of contrast enhancement and image quality using different contrast administration protocols for routine abdominal Computed Tomography (CT) in two centers |
title_short |
Comparison of contrast enhancement and image quality using different contrast administration protocols for routine abdominal Computed Tomography (CT) in two centers |
title_full |
Comparison of contrast enhancement and image quality using different contrast administration protocols for routine abdominal Computed Tomography (CT) in two centers |
title_fullStr |
Comparison of contrast enhancement and image quality using different contrast administration protocols for routine abdominal Computed Tomography (CT) in two centers |
title_full_unstemmed |
Comparison of contrast enhancement and image quality using different contrast administration protocols for routine abdominal Computed Tomography (CT) in two centers |
title_sort |
comparison of contrast enhancement and image quality using different contrast administration protocols for routine abdominal computed tomography (ct) in two centers |
publishDate |
2021 |
url |
http://eprints.usm.my/60619/1/Poh%20Choon%20Sian-E.pdf http://eprints.usm.my/60619/ |
_version_ |
1804065722634076160 |
score |
13.211869 |