Characterization of EBT3 radiochromic film for precise measurement of output factors in stereotactic radiosurgery

Radiochromic film become a demanding tool in a work of characterizing dosimetric properties in small field stereotactic radiosurgery. The aim of this project is to perform a comparative study in measuring output factor using EBT3 radiochromic film and PTW PinPoint Ion Chamber. Output factor measu...

Full description

Saved in:
Bibliographic Details
Main Author: Alam, Nur Zarifha Zainol
Format: Monograph
Language:English
Published: Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia 2015
Subjects:
Online Access:http://eprints.usm.my/58209/1/NUR%20ZARIFHA%20BINTI%20ZAINOL%20ALAM%20-%20e.pdf
http://eprints.usm.my/58209/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.58209
record_format eprints
spelling my.usm.eprints.58209 http://eprints.usm.my/58209/ Characterization of EBT3 radiochromic film for precise measurement of output factors in stereotactic radiosurgery Alam, Nur Zarifha Zainol RD520-599.5 Surgery by region, system, or organ Radiochromic film become a demanding tool in a work of characterizing dosimetric properties in small field stereotactic radiosurgery. The aim of this project is to perform a comparative study in measuring output factor using EBT3 radiochromic film and PTW PinPoint Ion Chamber. Output factor measurements using EBT3 films and PTW PinPoint Ion Chamber were performed using 6MV photon beam from medical linear accelerator .The measurements was done in solid water phantom and CNMC Model 74-320 water phantom. Measurements were done at dmax (1.5cm ) depth inside water phantom and 100 cm source surface distance. Results: Percentage difference of measured output factor with EBT3 Gafchromic film and PTW Ion PinPoint Chamber was approximately 10-11%. Analysis on dose response for EBT3 and EBT2 gives difference approximately 4% in magnitude. The result obtained for scanning orientation study show minimal difference in output factors for different side orientation which differs by less than 2%. Variations for all doses were found to be less than 0.16 (net difference of optical density) for 4°C and 28°C but 0.026 for 37°C. Net optical density for the films stored in 37°C recorded huge difference in relative standard deviation which approximately only 4% compared to 4°C and 28°C which are 34-37% but still represents linear relationship with dose. EBT3 is suitable for measurements of output factor in stereotactic radiosurgery and can be use on validation of dose when high spatial resolution is required for clinical practice. Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia 2015 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/58209/1/NUR%20ZARIFHA%20BINTI%20ZAINOL%20ALAM%20-%20e.pdf Alam, Nur Zarifha Zainol (2015) Characterization of EBT3 radiochromic film for precise measurement of output factors in stereotactic radiosurgery. Project Report. Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic RD520-599.5 Surgery by region, system, or organ
spellingShingle RD520-599.5 Surgery by region, system, or organ
Alam, Nur Zarifha Zainol
Characterization of EBT3 radiochromic film for precise measurement of output factors in stereotactic radiosurgery
description Radiochromic film become a demanding tool in a work of characterizing dosimetric properties in small field stereotactic radiosurgery. The aim of this project is to perform a comparative study in measuring output factor using EBT3 radiochromic film and PTW PinPoint Ion Chamber. Output factor measurements using EBT3 films and PTW PinPoint Ion Chamber were performed using 6MV photon beam from medical linear accelerator .The measurements was done in solid water phantom and CNMC Model 74-320 water phantom. Measurements were done at dmax (1.5cm ) depth inside water phantom and 100 cm source surface distance. Results: Percentage difference of measured output factor with EBT3 Gafchromic film and PTW Ion PinPoint Chamber was approximately 10-11%. Analysis on dose response for EBT3 and EBT2 gives difference approximately 4% in magnitude. The result obtained for scanning orientation study show minimal difference in output factors for different side orientation which differs by less than 2%. Variations for all doses were found to be less than 0.16 (net difference of optical density) for 4°C and 28°C but 0.026 for 37°C. Net optical density for the films stored in 37°C recorded huge difference in relative standard deviation which approximately only 4% compared to 4°C and 28°C which are 34-37% but still represents linear relationship with dose. EBT3 is suitable for measurements of output factor in stereotactic radiosurgery and can be use on validation of dose when high spatial resolution is required for clinical practice.
format Monograph
author Alam, Nur Zarifha Zainol
author_facet Alam, Nur Zarifha Zainol
author_sort Alam, Nur Zarifha Zainol
title Characterization of EBT3 radiochromic film for precise measurement of output factors in stereotactic radiosurgery
title_short Characterization of EBT3 radiochromic film for precise measurement of output factors in stereotactic radiosurgery
title_full Characterization of EBT3 radiochromic film for precise measurement of output factors in stereotactic radiosurgery
title_fullStr Characterization of EBT3 radiochromic film for precise measurement of output factors in stereotactic radiosurgery
title_full_unstemmed Characterization of EBT3 radiochromic film for precise measurement of output factors in stereotactic radiosurgery
title_sort characterization of ebt3 radiochromic film for precise measurement of output factors in stereotactic radiosurgery
publisher Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia
publishDate 2015
url http://eprints.usm.my/58209/1/NUR%20ZARIFHA%20BINTI%20ZAINOL%20ALAM%20-%20e.pdf
http://eprints.usm.my/58209/
_version_ 1765297662571053056
score 13.211869