Cost Evaluation On The Effect Of Adopting Different Shear Wall Arrangements For Rectangular Office Building Under Seismic Design
Penang Island is located in the low seismic zone. However, due to the past earthquakes incidents that caused structural damage to a few buildings to the non-seismic design, it is vital to consider the involvement of seismic design (EC8) onto the construction of building that only complied to the...
Saved in:
Main Author: | |
---|---|
Format: | Monograph |
Language: | English |
Published: |
Universiti Sains Malaysia
2022
|
Subjects: | |
Online Access: | http://eprints.usm.my/58111/1/Cost%20Evaluation%20On%20The%20Effect%20Of%20Adopting%20Different%20Shear%20Wall%20Arrangements%20For%20Rectangular%20Office%20Building%20Under%20Seismic%20Design.pdf http://eprints.usm.my/58111/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.usm.eprints.58111 |
---|---|
record_format |
eprints |
spelling |
my.usm.eprints.58111 http://eprints.usm.my/58111/ Cost Evaluation On The Effect Of Adopting Different Shear Wall Arrangements For Rectangular Office Building Under Seismic Design Tan, Hong Yang T Technology TA Engineering (General). Civil engineering (General) Penang Island is located in the low seismic zone. However, due to the past earthquakes incidents that caused structural damage to a few buildings to the non-seismic design, it is vital to consider the involvement of seismic design (EC8) onto the construction of building that only complied to the non-seismic design (EC2). This study is carried out with the aim to evaluate the effect of different structural systems towards the concrete volume and reinforcement bar quantity, the total cost, and the net floor area of buildings under seismic design. Three types of reinforced concrete building frame of 25 storeys, 30 storeys and 35 storeys with the incorporation of different shear wall arrangements were designed and analysed using ETABS software package. The buildings were designed using EC2 and MS1553:2002 for gravity load and wind load, respectively. On the other hand, EC8 was used for seismic design with the reference Peak Ground Acceleration value of 0.05 g (low ductility class) and soil type D as it represents the seismicity conditions in Penang Island. The results showed that the total concrete volume and reinforcement bar cost for the building models with respect to building heights and different shear wall arrangements decreased in the range of 6.2%-16.1% for non-seismic design and 1.1%-10.6% for seismic design. This finding is associated to the fact that the incorporation of shear wall increases the building resistant towards lateral load. On the other hand, the net floor area was found to be insignificantly increased (1%-2%) when the incorporation of different shear wall arrangements is adopted. It can be concluded that incorporation of seismic design for Penang case increases the total material cost, although the additional cost can be considered as relatively low (less than 7%). On the contrary, the incorporation of additional shear wall reduces the total cost (1%-11%) and particularly true for all building heights with seismic design. In addition, the incorporation of additional shear wall slightly increases the net floor area and particularly true in the case of non-seismic and seismic design. Universiti Sains Malaysia 2022-07-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/58111/1/Cost%20Evaluation%20On%20The%20Effect%20Of%20Adopting%20Different%20Shear%20Wall%20Arrangements%20For%20Rectangular%20Office%20Building%20Under%20Seismic%20Design.pdf Tan, Hong Yang (2022) Cost Evaluation On The Effect Of Adopting Different Shear Wall Arrangements For Rectangular Office Building Under Seismic Design. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Awam. (Submitted) |
institution |
Universiti Sains Malaysia |
building |
Hamzah Sendut Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Sains Malaysia |
content_source |
USM Institutional Repository |
url_provider |
http://eprints.usm.my/ |
language |
English |
topic |
T Technology TA Engineering (General). Civil engineering (General) |
spellingShingle |
T Technology TA Engineering (General). Civil engineering (General) Tan, Hong Yang Cost Evaluation On The Effect Of Adopting Different Shear Wall Arrangements For Rectangular Office Building Under Seismic Design |
description |
Penang Island is located in the low seismic zone. However, due to the past
earthquakes incidents that caused structural damage to a few buildings to the non-seismic
design, it is vital to consider the involvement of seismic design (EC8) onto the construction
of building that only complied to the non-seismic design (EC2). This study is carried out
with the aim to evaluate the effect of different structural systems towards the concrete
volume and reinforcement bar quantity, the total cost, and the net floor area of buildings
under seismic design. Three types of reinforced concrete building frame of 25 storeys, 30
storeys and 35 storeys with the incorporation of different shear wall arrangements were
designed and analysed using ETABS software package. The buildings were designed using
EC2 and MS1553:2002 for gravity load and wind load, respectively. On the other hand, EC8
was used for seismic design with the reference Peak Ground Acceleration value of 0.05 g
(low ductility class) and soil type D as it represents the seismicity conditions in Penang
Island. The results showed that the total concrete volume and reinforcement bar cost for the
building models with respect to building heights and different shear wall arrangements
decreased in the range of 6.2%-16.1% for non-seismic design and 1.1%-10.6% for seismic
design. This finding is associated to the fact that the incorporation of shear wall increases
the building resistant towards lateral load. On the other hand, the net floor area was found to
be insignificantly increased (1%-2%) when the incorporation of different shear wall
arrangements is adopted. It can be concluded that incorporation of seismic design for Penang
case increases the total material cost, although the additional cost can be considered as
relatively low (less than 7%). On the contrary, the incorporation of additional shear wall
reduces the total cost (1%-11%) and particularly true for all building heights with seismic design. In addition, the incorporation of additional shear wall slightly increases the net floor
area and particularly true in the case of non-seismic and seismic design. |
format |
Monograph |
author |
Tan, Hong Yang |
author_facet |
Tan, Hong Yang |
author_sort |
Tan, Hong Yang |
title |
Cost Evaluation On The Effect Of Adopting Different Shear Wall Arrangements For Rectangular Office Building Under Seismic Design |
title_short |
Cost Evaluation On The Effect Of Adopting Different Shear Wall Arrangements For Rectangular Office Building Under Seismic Design |
title_full |
Cost Evaluation On The Effect Of Adopting Different Shear Wall Arrangements For Rectangular Office Building Under Seismic Design |
title_fullStr |
Cost Evaluation On The Effect Of Adopting Different Shear Wall Arrangements For Rectangular Office Building Under Seismic Design |
title_full_unstemmed |
Cost Evaluation On The Effect Of Adopting Different Shear Wall Arrangements For Rectangular Office Building Under Seismic Design |
title_sort |
cost evaluation on the effect of adopting different shear wall arrangements for rectangular office building under seismic design |
publisher |
Universiti Sains Malaysia |
publishDate |
2022 |
url |
http://eprints.usm.my/58111/1/Cost%20Evaluation%20On%20The%20Effect%20Of%20Adopting%20Different%20Shear%20Wall%20Arrangements%20For%20Rectangular%20Office%20Building%20Under%20Seismic%20Design.pdf http://eprints.usm.my/58111/ |
_version_ |
1765297648161521664 |
score |
13.211869 |