Analysis Of The Ultrasonic Cautery

Thermal cautery is a device used by surgeon in surgical operation to replace scalpel and to mitigate bleeding. The most popular cautery that used today is electrocautery. For the electrocautery, the current design of the thermal cautery facing safety issues while using it. One of the solution is i...

Full description

Saved in:
Bibliographic Details
Main Author: Lee, Han Wei
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2018
Subjects:
Online Access:http://eprints.usm.my/54117/1/Analysis%20Of%20The%20Ultrasonic%20Cautery_Lee%20Han%20Wei_M4_2018.pdf
http://eprints.usm.my/54117/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.54117
record_format eprints
spelling my.usm.eprints.54117 http://eprints.usm.my/54117/ Analysis Of The Ultrasonic Cautery Lee, Han Wei T Technology TJ Mechanical engineering and machinery Thermal cautery is a device used by surgeon in surgical operation to replace scalpel and to mitigate bleeding. The most popular cautery that used today is electrocautery. For the electrocautery, the current design of the thermal cautery facing safety issues while using it. One of the solution is introducing the ultrasonic technology in cautery. Both the usage of the electrocautery and ultrasonic cautery is compared show that the ultrasonic cautery has its advantages of safety features and has lower side effect to the patient after the surgery although the electrocautery has the advantages of cheaper in price, lighter and easier in maintenance. The information on the technology and working principle on the design of ultrasonic cautery does not given in any source thus the research and analysis on the technology and working principles of an ultrasonic cautery is important before any design work or improvement can be done. A review on the current design of the ultrasonic cautery has been done and it shows that most ultrasonic cautery need to be operate between 20kHz to 60kHz.Piezoelectric is used as the actuator to produce ultrasonic frequency due to its popularity in usage and has relative simpler usage. The control system to control the piezoelectric actuator is set up to control the piezoelectric actuator. The principles involve in a piezoelectric actuator is studied and experimented. Then amplification mechanism to amplify the amplitude of a piezoelectric actuator which has only 5 Universiti Sains Malaysia 2018-06-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/54117/1/Analysis%20Of%20The%20Ultrasonic%20Cautery_Lee%20Han%20Wei_M4_2018.pdf Lee, Han Wei (2018) Analysis Of The Ultrasonic Cautery. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Mekanikal. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic T Technology
TJ Mechanical engineering and machinery
spellingShingle T Technology
TJ Mechanical engineering and machinery
Lee, Han Wei
Analysis Of The Ultrasonic Cautery
description Thermal cautery is a device used by surgeon in surgical operation to replace scalpel and to mitigate bleeding. The most popular cautery that used today is electrocautery. For the electrocautery, the current design of the thermal cautery facing safety issues while using it. One of the solution is introducing the ultrasonic technology in cautery. Both the usage of the electrocautery and ultrasonic cautery is compared show that the ultrasonic cautery has its advantages of safety features and has lower side effect to the patient after the surgery although the electrocautery has the advantages of cheaper in price, lighter and easier in maintenance. The information on the technology and working principle on the design of ultrasonic cautery does not given in any source thus the research and analysis on the technology and working principles of an ultrasonic cautery is important before any design work or improvement can be done. A review on the current design of the ultrasonic cautery has been done and it shows that most ultrasonic cautery need to be operate between 20kHz to 60kHz.Piezoelectric is used as the actuator to produce ultrasonic frequency due to its popularity in usage and has relative simpler usage. The control system to control the piezoelectric actuator is set up to control the piezoelectric actuator. The principles involve in a piezoelectric actuator is studied and experimented. Then amplification mechanism to amplify the amplitude of a piezoelectric actuator which has only 5
format Monograph
author Lee, Han Wei
author_facet Lee, Han Wei
author_sort Lee, Han Wei
title Analysis Of The Ultrasonic Cautery
title_short Analysis Of The Ultrasonic Cautery
title_full Analysis Of The Ultrasonic Cautery
title_fullStr Analysis Of The Ultrasonic Cautery
title_full_unstemmed Analysis Of The Ultrasonic Cautery
title_sort analysis of the ultrasonic cautery
publisher Universiti Sains Malaysia
publishDate 2018
url http://eprints.usm.my/54117/1/Analysis%20Of%20The%20Ultrasonic%20Cautery_Lee%20Han%20Wei_M4_2018.pdf
http://eprints.usm.my/54117/
_version_ 1743107787173396480
score 13.211869