Photovoltaic Thermal Collector System Based On Heterojunction Intrinsic (HIT) Panel

In this project, Photovoltaic thermal or PVT system based on heterojunction intrinsic (HIT) panel was designed, built and tested. This system not only produces electricity but it also generates hot water. HIT PV solar panel with the solar thermal collector and without thermal collector will be pre...

Full description

Saved in:
Bibliographic Details
Main Author: Rosli, Muhammad Nasrul Faiz
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2018
Subjects:
Online Access:http://eprints.usm.my/53604/1/Photovoltaic%20Thermal%20Collector%20System%20Based%20On%20Heterojunction%20Intrinsic%20%28HIT%29%20Panel_Muhammad%20Nasrul%20Faiz%20Rosli_E3_2018.pdf
http://eprints.usm.my/53604/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.53604
record_format eprints
spelling my.usm.eprints.53604 http://eprints.usm.my/53604/ Photovoltaic Thermal Collector System Based On Heterojunction Intrinsic (HIT) Panel Rosli, Muhammad Nasrul Faiz T Technology TK Electrical Engineering. Electronics. Nuclear Engineering In this project, Photovoltaic thermal or PVT system based on heterojunction intrinsic (HIT) panel was designed, built and tested. This system not only produces electricity but it also generates hot water. HIT PV solar panel with the solar thermal collector and without thermal collector will be presented and analysed. The first objective of this project is to design and test a PVT system based on heterojunction intrinsic (HIT) panel. The second objective is to compare the performance of the heterojunction intrinsic (HIT) panel with and without the thermal collector. Microcontroller data acquisition was built to measure and collect data from the system. All the electrical parameter were saved on micro SD card for every 5 minutes using data logger developed using Arduino. The data collected were used to observe the I-V characteristics of HIT panel with and without thermal collector and also the energy output generated from the system. The experiment was conducted for 5 hours to obtain output current, output voltage and maximum output power. From the result analysis, the HIT with thermal collector has improved its performance by 22.64% and lowered the solar panel temperature by 9.49%. Universiti Sains Malaysia 2018-06-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/53604/1/Photovoltaic%20Thermal%20Collector%20System%20Based%20On%20Heterojunction%20Intrinsic%20%28HIT%29%20Panel_Muhammad%20Nasrul%20Faiz%20Rosli_E3_2018.pdf Rosli, Muhammad Nasrul Faiz (2018) Photovoltaic Thermal Collector System Based On Heterojunction Intrinsic (HIT) Panel. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Elektrik dan Elektronik. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic T Technology
TK Electrical Engineering. Electronics. Nuclear Engineering
spellingShingle T Technology
TK Electrical Engineering. Electronics. Nuclear Engineering
Rosli, Muhammad Nasrul Faiz
Photovoltaic Thermal Collector System Based On Heterojunction Intrinsic (HIT) Panel
description In this project, Photovoltaic thermal or PVT system based on heterojunction intrinsic (HIT) panel was designed, built and tested. This system not only produces electricity but it also generates hot water. HIT PV solar panel with the solar thermal collector and without thermal collector will be presented and analysed. The first objective of this project is to design and test a PVT system based on heterojunction intrinsic (HIT) panel. The second objective is to compare the performance of the heterojunction intrinsic (HIT) panel with and without the thermal collector. Microcontroller data acquisition was built to measure and collect data from the system. All the electrical parameter were saved on micro SD card for every 5 minutes using data logger developed using Arduino. The data collected were used to observe the I-V characteristics of HIT panel with and without thermal collector and also the energy output generated from the system. The experiment was conducted for 5 hours to obtain output current, output voltage and maximum output power. From the result analysis, the HIT with thermal collector has improved its performance by 22.64% and lowered the solar panel temperature by 9.49%.
format Monograph
author Rosli, Muhammad Nasrul Faiz
author_facet Rosli, Muhammad Nasrul Faiz
author_sort Rosli, Muhammad Nasrul Faiz
title Photovoltaic Thermal Collector System Based On Heterojunction Intrinsic (HIT) Panel
title_short Photovoltaic Thermal Collector System Based On Heterojunction Intrinsic (HIT) Panel
title_full Photovoltaic Thermal Collector System Based On Heterojunction Intrinsic (HIT) Panel
title_fullStr Photovoltaic Thermal Collector System Based On Heterojunction Intrinsic (HIT) Panel
title_full_unstemmed Photovoltaic Thermal Collector System Based On Heterojunction Intrinsic (HIT) Panel
title_sort photovoltaic thermal collector system based on heterojunction intrinsic (hit) panel
publisher Universiti Sains Malaysia
publishDate 2018
url http://eprints.usm.my/53604/1/Photovoltaic%20Thermal%20Collector%20System%20Based%20On%20Heterojunction%20Intrinsic%20%28HIT%29%20Panel_Muhammad%20Nasrul%20Faiz%20Rosli_E3_2018.pdf
http://eprints.usm.my/53604/
_version_ 1739829001566814208
score 13.244404