Cooling Potential Of Passive Roof Treatments On The Concrete Flat Roof In Penang, Malaysia

The rise in global temperature due to global warming has a major impact on the environment and building occupants. The higher concentration of greenhouse gases, in the atmosphere, especially carbon dioxide (CO2), is thought to be the reason for this phenomenon. Higher outdoor and indoor air tempe...

Full description

Saved in:
Bibliographic Details
Main Author: Ismail, Asmat
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.usm.my/45254/1/Asmat%20Binti%20Ismail24.pdf
http://eprints.usm.my/45254/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.45254
record_format eprints
spelling my.usm.eprints.45254 http://eprints.usm.my/45254/ Cooling Potential Of Passive Roof Treatments On The Concrete Flat Roof In Penang, Malaysia Ismail, Asmat TH1-9745 Building construction The rise in global temperature due to global warming has a major impact on the environment and building occupants. The higher concentration of greenhouse gases, in the atmosphere, especially carbon dioxide (CO2), is thought to be the reason for this phenomenon. Higher outdoor and indoor air temperatures lead to higher energy consumption in buildings due to the excessive use of air conditioning and other mechanical ventilation systems. Implementing passive cooling systems into the building elements can be a promising way to overcome this problem. From the literature, passive cooling techniques using green roof, double roof, and reflective roof (white roof) technologies could have a positive impact on the building environment. However, the cooling potential of these technologies varies depending on their design and the type of climate. Therefore, in order to investigate the effectiveness of these technologies in the Malaysian climate, a comparative study of these passive cooling technologies is carried out in this research. A series of field experimental studies has been carried out on a real building, i.e., on the flat roof of a single-storey residential building, in the actual weather conditions. The indoor and outdoor environments were monitored in this research to evaluate the most effective passive cooling roof treatment between the potted plant green roof (roof with potted plants), double roof (roof with 6 inches ventilated air gap) and white roof. The results show a significant cooling effect for all strategies. The highest indoor-outdoor air temperature difference, which is the main criteria in determining the cooling effect, is taken into account in this research. 2013-07 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/45254/1/Asmat%20Binti%20Ismail24.pdf Ismail, Asmat (2013) Cooling Potential Of Passive Roof Treatments On The Concrete Flat Roof In Penang, Malaysia. PhD thesis, Universiti Sains Malaysia.
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic TH1-9745 Building construction
spellingShingle TH1-9745 Building construction
Ismail, Asmat
Cooling Potential Of Passive Roof Treatments On The Concrete Flat Roof In Penang, Malaysia
description The rise in global temperature due to global warming has a major impact on the environment and building occupants. The higher concentration of greenhouse gases, in the atmosphere, especially carbon dioxide (CO2), is thought to be the reason for this phenomenon. Higher outdoor and indoor air temperatures lead to higher energy consumption in buildings due to the excessive use of air conditioning and other mechanical ventilation systems. Implementing passive cooling systems into the building elements can be a promising way to overcome this problem. From the literature, passive cooling techniques using green roof, double roof, and reflective roof (white roof) technologies could have a positive impact on the building environment. However, the cooling potential of these technologies varies depending on their design and the type of climate. Therefore, in order to investigate the effectiveness of these technologies in the Malaysian climate, a comparative study of these passive cooling technologies is carried out in this research. A series of field experimental studies has been carried out on a real building, i.e., on the flat roof of a single-storey residential building, in the actual weather conditions. The indoor and outdoor environments were monitored in this research to evaluate the most effective passive cooling roof treatment between the potted plant green roof (roof with potted plants), double roof (roof with 6 inches ventilated air gap) and white roof. The results show a significant cooling effect for all strategies. The highest indoor-outdoor air temperature difference, which is the main criteria in determining the cooling effect, is taken into account in this research.
format Thesis
author Ismail, Asmat
author_facet Ismail, Asmat
author_sort Ismail, Asmat
title Cooling Potential Of Passive Roof Treatments On The Concrete Flat Roof In Penang, Malaysia
title_short Cooling Potential Of Passive Roof Treatments On The Concrete Flat Roof In Penang, Malaysia
title_full Cooling Potential Of Passive Roof Treatments On The Concrete Flat Roof In Penang, Malaysia
title_fullStr Cooling Potential Of Passive Roof Treatments On The Concrete Flat Roof In Penang, Malaysia
title_full_unstemmed Cooling Potential Of Passive Roof Treatments On The Concrete Flat Roof In Penang, Malaysia
title_sort cooling potential of passive roof treatments on the concrete flat roof in penang, malaysia
publishDate 2013